SYSTEM SWITCH FUNCTIONS  
SPECIAL INSTRUCTIONS FOR DUAL FUEL APPLICATIONS  
Sw1 - Fan Relay  
Sw2 - Equipment  
Leave Switch 1 OFF  
(factory default).  
When the T-32-P2 is used with dual fuel systems,  
an outdoor sensor is recommended for balance  
point control (Model T-32-S1). The sensor is wired  
to the TT terminals on the thermostat. In the  
Advanced Installer Settings, set TT = OA. This  
configures the thermostat to receive the outdoor  
temperature information. High and low balance  
point settings are also set in the Advanced  
Installer Settings.  
HB = 55 is the factory default high balance point  
setting and LB = 35 is the factory default low  
balance point setting in degrees Fahrenheit. High  
balance point is adjustable from 32° F to 122° F  
and low balance point is adjustable from 15° F to  
77° F.  
Switch 2 sets the equipment  
configuration. For heat / cool  
equipment, set the switch to the OFF  
position (factory default). For heat  
pump equipment, set the switch  
to the ON position.  
Sw3 - Equipment Stages  
Switch 3 sets the equipment stages.  
For single stage equipment, set the  
switch to the OFF position (factory  
default). For multi-stage equipment,  
set the switch to the ON position.  
Sw4 - Fan Mode or Reversing Valve  
Switch 4 sets the fan logic for heat / cool  
systems or sets the reversing valve  
configuration for heat pump systems.  
Fan Mode - For gas or oil systems  
(equipment controls fan in heating mode),  
set the switch to the OFF position (factory  
default). For electric systems (thermostat  
controls fan in heating mode), set the switch  
to the ON position.  
It is very important that the W2 relay be  
configured to lock out the heat pump on low  
balance point or whenever the thermostat calls  
for auxiliary or emergency heat. In the  
Advanced Installer Settings, set H3 = FF.  
Reversing Valve - For ‘O’ reversing valve  
(energize in cooling), set the switch to the  
OFF position (factory default). For ‘B’  
reversing valve (energize in heating), set the  
switch to the ON position.  
ACTIVATING THE BATTERY  
Sw5 - Short Cycle Timer  
The T-32-P2 contains a 3  
REMOVE TAB  
Leave switch 5 ON for 4 minute short cycle  
protection (factory default).  
volt  
Lithium cell battery that  
maintains the time of day in  
the event of a power failure.  
To activate the battery,  
carefully remove the white  
tab.  
Sw6 - Thermostat Operation  
ON  
1 2 3 4 5 6 7 8  
Switch 6 sets the thermostat operation.  
For programmable, set the switch in the  
ON position (factory default).  
For non-programmable, set the switch  
in the OFF position.  
. . . . . . . . . . . .  
Sw7 - Minimum Run Time  
F
I
G
U
R
E
4
Leave switch 7 to OFF for 2 minute minimum  
run time (factory default).  
Sw8 - Program Schedule  
Leave switch 8 to ON for separate heating  
and cooling setpoints (factory default).  
SETTING THE SYSTEM SWITCHES  
The T-32-P2 contains a set  
of eight system switches  
located on the thermostat  
FACTORY DEFAULT SETTINGS  
ON  
printed circuit board. The  
1 2 3 4 5 6 7 8  
SWITCH  
1 - Fan  
ON/OFF  
OFF  
FUNCTION  
Fan Relay  
Heat / Cool  
1 Stage  
switches are used to match  
the thermostat with the  
specific type of HVAC  
system and user  
preferences. Refer to the  
2 - Equipment  
3 - Stages  
OFF  
. . . . . . . . . . . .  
FIGURE 5  
OFF  
system switch functions to  
properly configure the  
thermostat.  
4 - Fan Mode /  
Reversing Valve  
OFF  
Equipment Controls Fan /  
‘O’ Reversing Valve  
5 - Short Cycle Timer  
6 - Operation  
ON  
4 Minute Short Cycle Protection  
(Figure 5)  
OFF  
OFF  
ON  
Manual  
7 - Minimum Run Time  
8 - Setpoints  
2 Minutes  
Leave switch 8 to ON for  
separate heating and  
cooling setpoints.  
6
GeneralDetails
NameiO HVAC Controls T-32-P2 Universal Thermostat Instruction Manual
MakeiO HVAC Controls
LanguageEnglish
FiletypePDF (Download)
File size0.36 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
iO HVAC Controls UT32 Titan 3H or 2C Touchscreen Thermostat Owner’s Manual
iO HVAC Controls UT32 Titan 3H or 2C Touchscreen Thermostat Owner’s Manual
iO HVAC CONTROLS Z-2000-T Thermostat Instruction Manual
iO HVAC CONTROLS Z-2000-T Thermostat Instruction Manual

iO HVAC Controls T-32-P2 Universal Thermostat Instruction Manual