TROUBLESHOOTING TIPS
Problem
Solution
No Display
Check for 24 VAC; display is blank
when 24 VAC is not present
System fan does not Verify that wiring is correct.
come on properly
All thermostat
buttons are
inoperative
Verify that 24 VAC is present; unit
will not operate when 24 VAC is not
present.
Thermostat turns
on and off too
frequently
Adjust temperature differential
(see Configuration Mode - Setting
Temperature Differential, Stage 1,
Stage 2, and Stage 3 section).
Fan runs
continuously
Check fan selection. If set to ON, fan
will run.
Room temperature
is not correct
Verify that wall hole is plugged
with putty or insulation to prevent
airflow from the wall cavity. Adjust
Temperature Offset (see Configuration
Mode - Room temperature offset
section).
Compressor doesn’t There is a 3 minute time delay and
run or turn off
immediately when
changing function
or setting
a 3 minute minimum run time for the
compressor when it turns on/off.
Fan doesn’t run or
This is normal. On some models, the
turn off immediately fan may have a minimum run time/off
when changing
time delay.
function or setting
Problem not listed
above
Press the Reset button once to reset
the thermostat microprocessor.
15
| General | Details |
|---|---|
| Name | GE APPLIANCES RAK150VF2 Wall Thermostat Instruction Manual |
| Make | GE Appliances |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |

GE APPLIANCES RAK160W2 Wireless Thermostat User Manual

GE APPLIANCES RAK190V Energy Management Thermostat Owner’s Manual

GE APPLIANCES RAK190V 2 Way Energy Management Thermostat Instruction Manual

GE APPLIANCES RAK150VF2 Digital Wall Thermostat Instruction Manual

GE APPLIANCES THERMOSTAT Owner’s Manual