29
Time Display
1
When Schedule function is activated: 0: Time,
week, current time period displays. 1: Week and
current time period displays. 2: Time, week and
current time period does not display.
0
0-2
Selection
30
Fan Shutdown
Delay Time
1
This parameter is valid only when the fan mode is
AUTO. 0: When the compressor is shut down, the
fan is also shut down. 1-127: The fan shuts down in
a delay of n*minutes after the compressor is shut
down, unit: minute
0
0-127
31
Compressor
delay countdown
display
1
1
1
0: No Display
0
0-1
1: Display
32
45
Whether to
0: Disable
1
0-1
enable electrical
auxiliary heat
1: Enable
Schedule
Function
Selection
0: Disabled 1: Enabled
0
0-1
46
47
48
49
The 1st period
from Mon-Sun
2
2
2
2
Byte1(MSB): Minute Byte2(LSB): Hour
Byte1(MSB): Minute Byte2(LSB): Hour
Byte1(MSB): Minute Byte2(LSB): Hour
Byte1(MSB): Minute Byte2(LSB): Hour
Byte1: 0
Byte1: 0-59
Byte2: 6 Byte2: 0-23
The 2nd period
from Mon-Sun
Byte1: 0
Byte1: 0-59
Byte2: 8 Byte2: 0-23
The 3nd period
from Mon-Sun
Byte1: 0
Byte1: 0-59
Byte2: 18 Byte2: 0-23
The 4nd period
from Mon-Sun
Byte1: 0
Byte1: 0-59
Byte2: 22 Byte2: 0-23