ezlo EZL-TSTAT-US Wave Thermostat Instruction Manual
Navigating the Thermostat menu
Setpoint Seting
Secret Menu
Press “▲” or “▼ ” to set the desired indoor
temperature, default seting range: 5~37°C (seting
step is 0.5) and 41~98 °F (seting step is 1) by
default. During the seting, “SET” icon displays and
after finishing the seting, press any buton to save
the seting and exit.
Under "OFF" interface, long press “▼ ” + “⦾” buton
for 3 sec to enter parameter seting interface.
Short press " ▼" or “▲” buton to switch the
parameter value, short press “⦾ ”buton to set the
next item. Long pressing “▼ ” +“⦾ ” buton for 1 sec
or without any operation over 20 sec will exit the
seting.
Mode Seting
When the screen is on, press ⦾ buton and the
current mode icon flashes, press ⦾ buton again, it
will loop to switch working mode from OFF —
>HEAT —>COOL —>AUTO —>AUX (emergency
heating). Press "▼" or "▲" or wait for 2 sec to
confirm the current seting mode, "MODE" icon
stop flashing.
Thermostat Setup for each system type
After completing the thermostat wiring, access the
Thermostats Secret menu to configure the system
setings and ensure proper operation in the correct
mode.
Secret menu .15 (Possible Values 0-7)
Default Value: 7
Fan Mode & Schedule Seting
0: One-stage Conventional cool only
When the screen is on, long press “⦾” for 3 sec and
enter seting interface,the seting sequence is: FAN
MODE —>SCHEDULE MODE —> WEEK —>TIME
—>EXIT. Short press“▼” or “▲”to change the
current value and it’s icon flashes, press “⦾” to
confirm the seting. If the SCHEDULE MODE is
enabled, the main page displays “SCHEDULE” icon.
Long press “⦾” for 1 sec or without any operation
over 20 sec will exit the seting.
1: Two-stage Conventional cool only
2: One-stage Conventional heat only
3: One-stage Conventional heat only (no fan)
4: Two-stage Conventional heat only
5: One-stage Conventional heat & cool
6: Two-stage Conventional heat & cool
7: One-stage Cool in heat pump
8: Two-stage Cool in heat pump
9: One-stage heat in heat pump (optional: Aux)
10: Two-stage heat in heat pump (optional: Aux)
11: One-stage heat & cool in heat pump (optional: Aux)
12: Two-stage heat & cool in heat pump (optional: Aux)
Fan On:
In this mode, the fan is always running when the
device turns on, and stops when the device turns
off.
See pages 23-25 for extra setings that may need
to be adjusted from the menu for each system
type. These can also be adjusted via Z-Wave
Configuration parameters mentioned on page 34.
Fan Auto:
In this mode, the fan runs both in cooling and
heating state; the fan stops when cooling or
heating is stopped, when the device is in shutdown
state, the fan stops.