Navigating the Thermostat menu  
Setpoint Seting  
Secret Menu  
Press “” or “” to set the desired indoor  
temperature, default seting range: 5~37°C (seting  
step is 0.5) and 41~98 °F (seting step is 1) by  
default. During the seting, “SET” icon displays and  
after finishing the seting, press any buton to save  
the seting and exit.  
Under "OFF" interface, long press “” + “” buton  
for 3 sec to enter parameter seting interface.  
Short press " " or “” buton to switch the  
parameter value, short press “”buton to set the  
next item. Long pressing “” +“” buton for 1 sec  
or without any operation over 20 sec will exit the  
seting.  
Mode Seting  
When the screen is on, press buton and the  
current mode icon flashes, press buton again, it  
will loop to switch working mode from OFF —  
>HEAT >COOL —>AUTO —>AUX (emergency  
heating). Press "" or "" or wait for 2 sec to  
confirm the current seting mode, "MODE" icon  
stop flashing.  
Thermostat Setup for each system type  
After completing the thermostat wiring, access the  
Thermostats Secret menu to configure the system  
setings and ensure proper operation in the correct  
mode.  
Secret menu .15 (Possible Values 0-7)  
Default Value: 7  
Fan Mode & Schedule Seting  
0: One-stage Conventional cool only  
When the screen is on, long press “” for 3 sec and  
enter seting interface,the seting sequence is: FAN  
MODE —>SCHEDULE MODE —> WEEK —>TIME  
—>EXIT. Short press“” or “”to change the  
current value and it’s icon flashes, press “” to  
confirm the seting. If the SCHEDULE MODE is  
enabled, the main page displays “SCHEDULE” icon.  
Long press “” for 1 sec or without any operation  
over 20 sec will exit the seting.  
1: Two-stage Conventional cool only  
2: One-stage Conventional heat only  
3: One-stage Conventional heat only (no fan)  
4: Two-stage Conventional heat only  
5: One-stage Conventional heat & cool  
6: Two-stage Conventional heat & cool  
7: One-stage Cool in heat pump  
8: Two-stage Cool in heat pump  
9: One-stage heat in heat pump (optional: Aux)  
10: Two-stage heat in heat pump (optional: Aux)  
11: One-stage heat & cool in heat pump (optional: Aux)  
12: Two-stage heat & cool in heat pump (optional: Aux)  
Fan On:  
In this mode, the fan is always running when the  
device turns on, and stops when the device turns  
o.  
See pages 23-25 for extra setings that may need  
to be adjusted from the menu for each system  
type. These can also be adjusted via Z-Wave  
Configuration parameters mentioned on page 34.  
Fan Auto:  
In this mode, the fan runs both in cooling and  
heating state; the fan stops when cooling or  
heating is stopped, when the device is in shutdown  
state, the fan stops.  
200 Broadacres Dr, Bloomfield, NJ 07003  
866-966-2272 • ezlo.com  
26  
property. empowered.  
GeneralDetails
Nameezlo EZL-TSTAT-US Wave Thermostat Instruction Manual
Makeezlo
LanguageEnglish
FiletypePDF (Download)
File size0.63 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

ezlo EZL-TSTAT-US Wave Thermostat Instruction Manual