Z-Wave Parameter Setings  
Number Name  
Size  
Information  
Default  
Possible Values  
72-78  
79-85  
86-92  
The 3rd period  
2
Byte1(MSB): Minute  
Byte2(LSB): Hour  
Byte1: 0  
Byte1: 0-59  
for Mon...Sun  
Byte2: 18  
Byte: 0-23  
The 4th period  
for Mon...Sun  
2
2
Byte1(MSB): Minute  
Byte2(LSB): Hour  
Byte1: 0  
Byte1: 0-59  
Byte2: 22  
Byte: 0-23  
The 1st heat  
SetPoint for  
Mon...Sun  
n*0.1 Celsius or n*0.1 Fahrenheit  
n*0.1 Celsius or n*0.1 Fahrenheit  
n*0.1 Celsius or n*0.1 Fahrenheit  
n*0.1 Celsius or n*0.1 Fahrenheit  
n*0.1 Celsius or n*0.1 Fahrenheit  
n*0.1 Celsius or n*0.1 Fahrenheit  
n*0.1 Celsius or n*0.1 Fahrenheit  
n*0.1 Celsius or n*0.1 Fahrenheit  
1: Restore factory seting 0: Invalid  
Celsius: 210  
The range is greater than the  
Fahrenheit: 700 lower limit and smaller than the  
upper limit  
93-99  
The 2nd heat  
SetPoint for  
Mon...Sun  
2
2
2
2
2
2
2
1
Celsius: 165  
The range is greater than the  
Fahrenheit: 620 lower limit and smaller than the  
upper limit  
100-  
106  
The 3rd heat  
SetPoint for  
Mon...Sun  
Celsius: 210  
The range is greater than the  
Fahrenheit: 700 lower limit and smaller than the  
upper limit  
107-  
113  
The 4th heat  
SetPoint for  
Mon...Sun  
Celsius: 165  
The range is greater than the  
Fahrenheit: 620 lower limit and smaller than the  
upper limit  
114-  
120  
The 1st cool  
SetPoint for  
Mon...Sun  
Celsius: 255  
The range is greater than the  
Fahrenheit: 780 lower limit and smaller than the  
upper limit  
121-  
127  
The 2nd cool  
SetPoint for  
Mon...Sun  
Celsius: 295  
The range is greater than the  
Fahrenheit: 850 lower limit and smaller than the  
upper limit  
128-  
134  
The 3rd cool  
SetPoint for  
Mon...Sun  
Celsius: 255  
The range is greater than the  
Fahrenheit: 780 lower limit and smaller than the  
upper limit  
135-  
141  
The 4th cool  
SetPoint for  
Mon...Sun  
Celsius: 280  
The range is greater than the  
Fahrenheit: 820 lower limit and smaller than the  
upper limit  
255  
Factory Restore  
0
0-1  
200 Broadacres Dr, Bloomfield, NJ 07003  
866-966-2272 • ezlo.com  