ezlo EZL-TSTAT-US Wave Thermostat Instruction Manual
Z-Wave Parameter Setings
Number Name
Size
Information
Default
Possible
Values
23
24
25
2nd Temp.
1
Secret menu No. E13: accuracy: 0.1, Specifies the
additional minimum temperature difference after
the first stage turns on before the second stage is
activated. (0.3-9 degrees)
10 (°C)
20 (°F)
3-90 (°C)
3-90 (°F)
Hysteresis
3rd Temp.
Hysteresis
1
1
Secret menu No. E14: accuracy: 0.1, Specifies the
additional minimum temperature difference after
the second stage turns on before the third stage is
activated. (0.3-9 degrees)
10 (°C)
20 (°F)
3-90 (°C)
3-90 (°F)
System Control
Type
Secret menu No. E15:
12
0-12
See the Controlling Type for details
Note: This parameter does not change after
factory setings are restored. To be more
compatible with gateways, after seting this
parameter, please add in the gateway again.
26
Changeover
Valve Logic
1
Secret menu No. E16: 0=When the heat pump
starts cooling, O/B turns on; when the heat pump
starts heating, O/B turns off 1=When the heat
pump starts heating, O/B turns on; when the heat
pump starts cooling, O/B turns off
0
0-1
27
28
Compressor
1
1
Secret menu No. E17: The seting of compressor
1
0-10
0-1
Protection Time
delay time from shutdown to startup, unit: min
EM Emergency
Heat Mode
Secret menu No. E18: 1: ON 0: OFF Note: This mode
is only valid for heat pump system with heating
function
0
200 Broadacres Dr, Bloomfield, NJ 07003
866-966-2272 • ezlo.com
34
property. empowered.
| General | Details |
|---|---|
| Name | ezlo EZL-TSTAT-US Wave Thermostat Instruction Manual |
| Make | ezlo |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.63 MB |