ezlo EZL-TSTAT-US Wave Thermostat Instruction Manual
Z-Wave Parameter Setings
Number Name
Size
Information
Default
Possible
Values
17
18
Temp. Lower
1
Secret menu No. E07: Temperature lower limit
5 (°C)
41 (°F)
0-98
Limit
value, accuracy n*1
Temp. Offset
1
Secret menu No. E08: Temperature offset value
0
(-99~+99) (°C)
(-99~+99) (°F)
(°C or °F) , accuracy 0.1 (n *0.1
19
Humidity Offset
1
1
Secret menu No. E09: Humidity offset value
0
0
-20~+20
0-3
20
Fan & Humidity
Display Select
Secret menu No. E10: Fan and humidity display
mode selection 0: The most simplest display, fan
mode and humidity will not display. 1: Display fan
mode 2: Display humidity 3: Display fan mode and
humidity Note: When schedule function is enabled,
the time, week, and time period are displayed, if
the humidity display at the same time, the
humidity and time are displayed alternately.
21
Panel Lock
1
Secret menu No. E11: 0: Disabled 1: Secret menu
operation is invalid, except for modifying
parameter 11, other operation is valid. 2: Secret
Menu operation, changing mode and setpoint is
invalid, only valid for adding/removing network or
modifying parameter 11. 3: Only valid for adding/
removing network.
0
0-3
22
1st Temp.
1
Secret menu No. E12: accuracy: 0.1, Specifies the
minimum temperature difference between the
room temperature and the desired setpoint before
the first stage of heating or cooling is allowed to
turn on. (0.3-9 degrees). For example, if the heat
setpoint is 68° and the 1st stage hysteresis is set to
2 degrees, the room temperature will need to reach
66° before the heat turns on.
10 (°C)
2 (°F)
3-90 (°C)
3-90 (°F)
Hysteresis