Home > EPH CONTROLS > EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual

EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual

Boiler Plus  
Page 1 of 2  
Operating Instructions  
CDTP2 Room Thermostat Hardwired  
Contents  
1. Factory default settings  
2. Specifications & wiring  
3. Mounting  
CAUTION!  
4. Installation  
5. Wiring diagram  
6. Frost protection  
Before commencing any work on the electrical  
connections, you must first disconnect the thermostat  
from the mains. None of the 230V connections must be  
live until the installation has been completed and the  
housing is closed. Only qualified electricians or authorised  
service staff are permitted to open the thermostat.  
7. Button / symbol description  
8. Resetting the thermostat  
9. Keypad lock and unlock  
10. Setting the date, time and operating mode  
11. Factory default program settings  
12. Adjusting the program settings for 5/2d  
13. Temporary override (Manual)  
14. Permanent override (Hold)  
15. Adjusting the switching differential  
16. Installer menu  
There are parts that may carry mains voltage behind the  
cover. The thermostat must not be left unsupervised  
when open. (Prevent non specialists and especially  
children from gaining access to it.)  
Important: Keep this document  
Prior to setting the thermostat, it is neccessary to complete all required settings described in this section.  
1. Factory default settings  
5°C  
6. Frost protection  
Contacts:  
Volt Free  
Frost protection is built into this thermostat, it is pre fixed at 5°C and is not  
adjustable.  
Temperature indicator:  
Switching differential:  
In built frost protection:  
Blue backlight activated :  
Clock:  
°C  
0.4°C  
5°C  
It will only be activated when the thermostat is in the stand by mode and  
the room temperature falls below 5°C.  
for 10 secs after any button is pressed  
24 hours  
Off  
Keypad lock:  
Operating mode:  
5/2 day  
7. Button / Symbol description  
Keypad lock symbol  
Heating ON symbol  
Current programme  
2. Specifications & wiring  
Power supply:  
230Vac 50Hz  
Power consumption:  
Temp. control range:  
Ambient temperature:  
Contact rating:  
8 VA  
5 ... 35°C  
0 ... 50°C  
8A 230Vac  
Day of the week  
Dimensions:  
84 x 84 x 30mm  
NTC 10K Ohm @ 25°C  
Adjustable from 0.2/0.4/0.6/0.8/1.0˚C  
Only operational in stand by mode  
Temperature sensor:  
Switching differential:  
Frost protection:  
Program  
P3  
Standby symbol  
Reset button  
Set point increase  
Set point decrease  
OK button  
3. Mounting  
The mounting height should be 1.5 meters above the floor level.  
The thermostat should be wall mounted in the room where the heating is to  
be controlled.  
Hold button  
Standby button  
Set button  
The place of installation should be chosen so that the sensor can measure the  
room temperature as accurately as possible.  
Choose the mounting location to prevent direct exposure to sunlight or other  
heating / cooling sources when mounted.  
8. Resetting the thermostat  
The unit can be fitted to:  
1. Recessed conduit boxes  
2. Surface mounting boxes  
3. Directly on walls.  
It is necessary to reset the thermostat prior to initial programming.  
RESET  
Press the  
‘NOwill appear on the screen.  
Press the button.  
button on the side of the thermostat.  
4. Installation  
Slacken the fastening screw on the bottom of the thermostat with a philips  
head screwdriver.  
‘YESwill appear on the screen.  
The thermostat is hinged and can be opened 180 degrees.  
Mount the unit as described in section 3.  
Press the ‘OKbutton to return to normal operation.  
Wire the thermostat according to the wiring diagram.  
Close the thermostat and tighten the fastening screw.  
OFF  
9. Keypad lock and unlock  
To lock the keypad, press and hold the  
will appear on the screen. The keypad is now locked.  
To unlock the keypad, press and hold the and buttons for 5 seconds.  
will disappear from the screen. The keypad is now unlocked.  
and  
buttons for 5 seconds.  
5. Wiring diagram  
3 2 1 L N  
INTERNAL WIRING DIAGRAM CDTP2  
ON COM OFF  
MAINS  
SUPPLY  
If mains voltage output is required, terminals L & 2 must be electrically linked.  
EPH Controls Ireland  
EPH Controls UK  
20221006_CDTP2_Opins_PK  
GeneralDetails
NameEPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual
MakeEPH CONTROLS
LanguageEnglish
FiletypePDF (Download)
File size0.19 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide
EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide
EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual
EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual
EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual
EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual
EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual
EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual
EPH Controls CDT2-24 24V Room Thermostat Installation Guide
EPH Controls CDT2-24 24V Room Thermostat Installation Guide
EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions
EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions
EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual
EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual
EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual
EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual
EPH CONTROLS CRT2 Room Thermostat Instruction Manual
EPH CONTROLS CRT2 Room Thermostat Instruction Manual
EPH CONTROLS CDC2 Cylinder Room Thermostat User Guide
EPH CONTROLS CDC2 Cylinder Room Thermostat User Guide

EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual
Get the free PDF manual for the EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Boiler Plus Operating instructions CDTP2 room thermostat hardwired Contents Factory default settings Specifications & wiring Mounting Installation Wiring diagram Frost protection Important: Keep this document Frost protection is built into this thermostat, it is pre-fixed at 5°C and is not adjustable. The mounting height should be 1.5 meters above the floor level. The thermostat should be wall mounted in the room where the heating is to be controlled. It is necessary to reset the thermostat prior to initial programming. To lock the keypad, press and hold the button. The keypad is now locked.
  • Page 2: Boiler Plus Operating Instructions Adjusting the switching differential Setting the date, time and operating mode To access the installer menu, you must hold OK and for 5 seconds. When the thermostat is in Normal mode, it will try to reach the target temperature after the program changes. When the thermostat is in Optimum Start mode, it will try to reach the target temperature by the start time of the next switching time. The target temperature difference (TTD) is the difference between the setpoint temperature and the room temperature. Programming for Monday to Friday is now selected. If 7D mode is selected, you can program each day of the week with 6 individual times and temperatures. Press the button to return to automatic mode.