Dec Hex
Value
range
Access
Description
Means
Default
150
Minimum floor temperature
To protect the floor, heating will be switched on,
when the floor sensor temperature drops
below the minimum value.
251 0x00FB R/W (#06)
50 - 450
N-> temp=N/10 °C
(Installer parameters -P21)
PIN code for installer settings
(Installer Parameters -P23)
0 = disabled
1 = PIN (First default code 0000)
254 0x00FE R/W (#06)
255 0x00FF R/W (#06)
0 - 1
0 - 1
0
0
Requiring a PIN code to unlock the keys
(Installer Parameters -P24)
0 = NIE
1 = TAK
0 = NO - Inactive - output contacts for fan control are
completely disabled
1 = YES
Fan operation
(Installer parameters -FAN)
256 0x0100 R/W (#06)
257 0x0101 R/W (#06)
258 0x0102 R/W (#06)
0 - 1
0,1
1
1
0
0=OFF
1=ON
Power on/off - switching off the regulator
Operation mode
0=Manual
1=Schedule
3=FROST - anti-freeze mode
0,1,3
0b000000= OFF - fan off
0b00000001= I (low) fan gear
0b000010= II (medium) fan gear
0b00000100= III (high) fan gear
260 0x0104 R/W (#06)
Fan speed setting
0b00001000= Automatic fan speed - OFF
0b00001001= Automatic fan speed - 1st gear
0b00001010= Automatic fan speed - 2nd gear
0b00001100= Automatic fan speed - 3rd gear
0=unlocked
1=Locked
262 0x0106 R/W (#06)
263 0x0107 R/W (#06)
Key lock
0,1
0
Display brightness
(Installer Parameters -P22)
0-100
N-> Brightness =N%
30
268 0x010C R/W (#06)
269 0x010D R/W (#06)
270 0x010E R/W (#06)
273 0x0111 R/W (#06)
274 0x0112 R/W (#06)
275 0x0113 R/W (#06)
279 0x0117 R/W (#06)
280 0x0118 R/W (#06)
284 0x011C R/W (#06)
Clock - minutes
0-59
0-23
Minutes
0
0
Clock - hours
Hours
Clock - Day of the week (1=Monday)
Set temperature in schedule mode
Set temperature in manual mode
Set temperature in FROST mode
Maximum setpoint temperature
Minimum setpoint temperature
Accuracy of displayed temperature
1~7
Day of the week
N-> temp=N/10 °C
N-> temp=N/10 °C
N-> temp=N/10 °C
N-> temp=N/10 °C
N-> temp=N/10 °C
N-> temp=N/10 °C
3
50-450
50-450
50
210
210
50
350
50
1
50-450
50-450
1, 5
R/W
285 0x011D
(#06))
-3.0...
3.0°C
Correction of displayed temperature
in steps of 0.5C
0
0
Selection of system type - heating / cooling
(dependent on the setting of input S1)
0 = Heating
1 = Cooling
288 0x0120 R/W (#06)
0,1
5
| General | Details |
|---|---|
| Name | Engo EFAN-230 Zigbee Smart Thermostat Owner’s Manual |
| Make | ENGO |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.12 MB |

ENGO E55W230WIFI Wi-Fi Thermostat User Guide

ENGO E20i Series Wi-Fi Wireless Internet Thermostat User Guide

ENGO EONEBATW, EONEBATB Internet Controlled Thermostat User Guide

ENGO E901 Programmable Wired Thermostat User Manual

ENGO E901 Wireless Internet Thermostat User Manual

ENGO EASY230W Wired Thermostat User Guide

ENGO EASYBATB Wired Battery Thermostat User Guide