Doit 474053 Low Voltage Thermostat Installation Guide

Two-Transformer Systems  
CAUTION  
!
If two transformers are used, they MUST be in phase.  
Failure to do so will result in personal and/or property  
damage.  
Heat Pump Applications  
Thissubbase WILLNOTprovidemulti-stageheatingorcooling. For  
single stage applications, install a short jumper wire across termi-  
nalsWandY.Iftheoldthermostathasaterminalthatiscontinuously  
energized, disconnect the wire from the old thermostat’s terminal  
and connect it either to the: (1) B terminal, if the reversing valve is  
energized on a call for heat; or to the (2) O terminal, if the reversing  
valve is energized on a call for cool. If the system heats on a call for  
cool or vice versa, this wire has been connected to the wrong  
terminal.  