Doit 474053 Low Voltage Thermostat Installation Guide
1. Remove thermostat cover.
2. If heat cycle is too long, set heat anticipator to a slightly lower
dial setting (about 1⁄
division at a time). If heat cycle is too short,
2
1
set heat anticipator to a slightly higher dial setting (about ⁄
division at a time).
2
3. Replace thermostat cover.
.25
.3
.4
.2
.5
.6
18
.8
.15
1.
Arrow points to the
matched current rating
of the primary control
Move this lever to
adjust heat
anticipator
Figure 9. Anticipator adjustment