Home > Dettson > Dettson 2-Stage WiFi Thermostat R02P033 Owner’s Manual

Dettson 2-Stage WiFi Thermostat R02P033 Owner’s Manual

3 Installer Menu  
In Schedule mode, hold  
and  
to reach the installer menu. Password is  
.
Use  
and  
to change the setting. Press  
to move to the next menu item.  
Item Parameter  
Range  
Default  
Note  
0.0: O ; 1.0: B  
See section 2.3  
Pb  
O/B selection  
0.0 / 1.1  
0.0  
Pc  
0
Auxiliary heat type *  
System mode  
0.0 / 1.1  
0.0  
0.0  
0.0: Electric ; 1.0: Gas/Oil  
See section 1.3  
0.0 - 7.0  
0.5 - 2.0°C  
-10 - 10°C  
0 - 37°C  
0 - 37°C  
1
1H/1C differential  
Temperature adjustment  
Max. set point  
1.0°C  
0.0°C  
37.0°C  
5.0°C  
Gap between the heat/cool stages.  
Display calibration  
2
3
4
max. > min.  
Min. set point  
5
Filter change reminder  
Clock format  
Compressor protection delay  
1 day - 120 days 90 days  
12 / 24 h  
0 - 10 min  
6
24.0  
1 min  
7
See section 2.3  
ON: Always ON  
OF: Dimmed when unused  
8
9
Backlight  
OF / ON  
OF  
Temperature format  
Factory reset  
°C / °F  
OF / ON  
°C  
OF  
ON: Reset  
* When Electric type is selected, the heat pump stays on when the auxiliary heat is activated.  
10  
GeneralDetails
NameDettson 2-Stage WiFi Thermostat R02P033 Owner’s Manual
MakeDettson
LanguageEnglish
FiletypePDF (Download)
File size0.15 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Dettson R02P034 Communicating Thermostat Instruction Manual
Dettson R02P034 Communicating Thermostat Instruction Manual

Dettson 2-Stage WiFi Thermostat R02P033 Owner’s Manual