3 Installer Menu
In Schedule mode, hold
and
to reach the installer menu. Password is
.
Use
and
to change the setting. Press
to move to the next menu item.
Item Parameter
Range
Default
Note
0.0: O ; 1.0: B
See section 2.3
Pb
O/B selection
0.0 / 1.1
0.0
Pc
0
Auxiliary heat type *
System mode
0.0 / 1.1
0.0
0.0
0.0: Electric ; 1.0: Gas/Oil
See section 1.3
0.0 - 7.0
0.5 - 2.0°C
-10 - 10°C
0 - 37°C
0 - 37°C
1
1H/1C differential
Temperature adjustment
Max. set point
1.0°C
0.0°C
37.0°C
5.0°C
Gap between the heat/cool stages.
Display calibration
2
3
4
max. > min.
Min. set point
5
Filter change reminder
Clock format
Compressor protection delay
1 day - 120 days 90 days
12 / 24 h
0 - 10 min
6
24.0
1 min
7
See section 2.3
ON: Always ON
OF: Dimmed when unused
8
9
Backlight
OF / ON
OF
Temperature format
Factory reset
°C / °F
OF / ON
°C
OF
ON: Reset
* When Electric type is selected, the heat pump stays on when the auxiliary heat is activated.