Danfoss FH-RT Wireless Room Thermostat Installation Guide
3.0 Installation instructions
4.0 Operating instructions
4.1 Thermal actuator installation
The system should be installed by a competent person in the following
sequence.
1.
2.
3.
4.
Ensure that the power supply to the base unit is disconnected.
Lift base unit cover after loosening front screws.
Remove internal aerial.
3.1 Base unit
Install the base unit first. Mount the base unit above the distribution manifold
either direct on the wall or inside a wooden or metal distribution cabinet.
Ensure that the base unit is mounted horizontally, that there is easy access
to the control panel and thermal actuator connections, and that the base
unit cover can be easily removed. Fix the base unit to the wall using two
screws.
Remove blue thermal actuator terminals from printed circuit
board.
5.
6.
Connect thermal actuator cables.
Reattach thermal actuator terminals in assigned order to printed circuit
board.
7.
8.
9.
Position cables in strain-relief cable glands (see Fig 3).
Replace internal aerial.
The base unit must be connected to a 230 volt supply via a double pole switch
socket outlet. If it is installed in a metal distribution cabinet, an aerial should
be installed outside the cabinet in order to improve radio communication.
Close base unit and tighten front screws
3.2 Thermostat installation
Thermostats should be mounted on an internal wall at a height of 1.2-1.5
metres above the floor, using screws and fixings.
Thermostats must not be placed on an external wall or near heat sources
such as television and stereo sets, ovens or similar. Thermostats should not
normally be placed where they can be affected by direct sunshine. In rooms
that are very humid or damp, e.g. bathrooms, thermostats must be placed
as far from moisture sources as possible.
3.3 Pre-installation
Thermostats must be registered in the base unit before being placed in
individual rooms.
When registering thermostats, it is important that the room in which they are
to be placed is written or marked on the rear of the thermostat. Thermostats
can then be registered in turn.
The channels to be used for individual rooms must therefore be decided
in advance.
Note: refer to section 4.3 for registration instructions
Fig. 3. Push cable through cable gland.
4.2 Base unit installation
Once the base unit has been mounted on the wall, all thermal actuators
have been connected and any connections for pump and boiler control
have been made, the thermostats can be registered. First, power up the
base unit. The green ‘Power’LED lights up.
Ca. 1,5m
Power
1
2
3
4
5
6
7
8
Mode
OK
Fig. 2a. Thermostat location
Fig. 4. Control panel. LED indicators 1-8 and ‘Power’ LED.
Fig. 2b. Thermostat installation
3
| General | Details |
|---|---|
| Name | Danfoss FH-RT Wireless Room Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.32 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide