8.3 Weekly programming  
8. Operating instructions  
The thermostat has six heating and cooling periods programmed each  
day: three Comfort periods (1, 3 and 5, with the required temperature  
when the room is occupied) and three Economy periods (2, 4 and 6, with  
the required temperature when the room is unoccupied). You can then  
select the time and set-point temperature for each of these periods.  
8.1 User interface display  
The user interface display is organised as follows:  
To set the weekly programme, press and hold the key  
four times until the weekday programme settings are displayed. To post  
the set-point temperature value, use the keys , then press to  
conrm and enter the next period setting. Repeat the procedure for each  
period and press once more to conrm and exit.  
Default settings for weekly programming  
, then press  
Energysaving  
Valve status  
System Mode  
Fan Speed  
Room Temp.  
Set Temp.  
Week  
Monday /  
Friday  
Monday /  
Period  
Friday  
(1 2 3 4 5 on  
display)  
Sunday  
Programmable  
Lock  
Manual  
Time  
(1 2 3 4 5 on  
display)  
(7 on display)  
Period  
Time  
06:00  
08:00  
11:30  
13:30  
17:00  
22:00  
Temp.  
20°C  
15°C  
15°C  
15°C  
22°C  
15°C  
Time  
06:00  
08:00  
11 :30  
13:30  
17:00  
22:00  
Temp.  
20°C  
20°C  
20°C  
20°C  
20°C  
15°C  
Time  
06:00  
08:00  
11:30  
13:30  
17:00  
22:00  
Temp.  
20°C  
20°C  
20°C  
20°C  
20°C  
15°C  
Period 1  
Period 2  
Period 3  
Period 4  
Period 5  
Period 6  
Power  
On/Off  
Mode Fan  
Up  
Down  
8.2 Operations  
The user interface display is organised as follows:  
Switching ON and OFF  
Press the key  
to switch the thermostat on or off  
Manual operation and programming  
While holding down the key  
, the icon ashes. Using the keys  
you can select between manual operation and programming.  
Set-point temperature  
When the thermostat is in manual mode, the set-point temperature can  
be selected using the keys  
. The icon  
is shown on the left side  
of the display.  
Key lock  
By holding down the keys  
for 5 seconds, the thermostat can be  
locked/unlocked. In the advanced programming settings, it is also  
possible to select between partial or full key lock.  
Operating modes  
By pressing the key  
, it is possible to switch between HEATING,  
COOLING and VENTILATION modes. In the latter, the solenoid valve (if  
present) remains closed while the fan is switched on.  
Fan speed  
By pressing the key  
you can select the fan speed among AUTO,  
HIGH, MED and LOW. With AUTO, the fan speed is modulated according  
to the dierence between the current temperature and the set-point  
temperature.  
Clock  
While holding down the key  
, the icon  
ashes. Press  
again to  
set hours, minutes and days of the week (1 = Monday, 2 = Tuesday,  
etc.) using the keys  
: after 3 seconds the value will be conrmed  
automaticall.  
- 12 -  
Cod. 1910000000402 - nv00  
GeneralDetails
NameCORDIVARI Stand Alone Control Thermostat for VENTANA Fan Coils User Manual
MakeCORDIVARI
LanguageEnglish
FiletypePDF (Download)
File size0.84 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
CORDIVARI Ardesia Electric Radiators with Digital Thermostat Instruction Manual
CORDIVARI Ardesia Electric Radiators with Digital Thermostat Instruction Manual