COPELAND 1F95G-1235GC Humidity Universal Thermostat Instruction Manual
OPERATINGYOUR THERMOSTAT
The second stage cooling should begin to operate and the
display should show "System On +2".
Heating/Humidifier
1. Press SYSTEM key to select HEAT. If the auxiliary heating
system has a standing pilot, be sure to light it.
4. Press to adjust the temperature setting above room
temperature. The cooling system should stop operating.
2. Press
to adjust thermostat setting to 1° above the
To check the dehumidifier when System On appears and
the cooling system is running press HUMIDITY* button once.
room temperature. The heat pump system should begin to
operate. The display should show "System On". How-
ever, if the system configuration is set to HP1 or HP2
and setpoint temperature display is flashing, the 5 minute
compressor lockout feature is operating (see Configura-
tion menu, item 12).
Press to adjust the humidity 2% or more below the room
humidity level setpoint range. DeHum On will appear indicat-
ing it is calling for the dehumidification.
If the room humidity is lower than the adjustment range, press
to 40% and hold it for four seconds. This will force the De-
Hum On for one complete cooling cycle to test the dehumidi-
fication equipment.
3. Adjust temperature setting to 3° above room temperature.
If your system configuration is set at MS2, HP1 or HP2,
the auxiliary heat system should begin to operate and the
display will show "System On +2".
After adjusting the humidity setting the display will return to
temperature in approximately 10 seconds. To switch the dis-
play back to temperature immediately after adjusting humidity
setting press HUMIDITY again.
4. Press to adjust the thermostat below room tempera-
ture. The heating system should stop operating.
To check the humidifier when System On appears and the
heating system is running press the HUMIDITY* button once.
*Note: If Auto Schedule is displayed instead of Humidity,
Auto Schedule must be turned off in the Configuration Menu.
Press
to adjust the humidity 2% or more above the room
humidity level setpoint range. (Humidity setpoint can be
adjusted from 5 to 50%.) Hum On will appear indicating it is
calling for the humidifier.
Choose the Fan Setting (Auto or On or Prog)
There are two fan features:
1. Fan Auto/On – Traditional Fan Settings
*Note: If Auto Schedule is displayed instead of Humidity,
Auto Schedule must be turned off in the Configuration Menu.
Press Fan to select Auto or On. The most commonly
used setting is Auto. Fan Auto runs the fan only when
the heating or cooling system is operating. Selecting Fan
On runs the fan continuously for increased air circulation
or to allow additional air cleaning if the system is equipped
with an Electronic Air Cleaner.
Emergency Mode
Applies only to Heat Pump Systems
Emergency Heat (System EM Position) bypasses the Heat
Pump to use the heat source wired to terminal W/E, W2 on
the thermostat. EM is typically used when compressor opera-
tion is not desired, or you prefer back-up heat only.
2. FAN Prog – Comfort Circulating Fan Feature
Pressing FAN until FAN Prog appears activates the Com-
fort Circulating Fan Option. This causes the thermostat to
cycle the fan on for 10 minutes and off for 20 minutes if the
thermostat has not called for heat or cool during the past
60 minutes. This assures moderate air circulation even
when the heating and cooling equipment is not cycling.
1. Press SYSTEM key to select EM. “EM Heat Mode” will
flash on the display.
2. Press
to adjust thermostat setting above room tem-
perature. The Emergency heating system will begin to
operate. The display will show “System On” flashing “EM
Heat Mode” and “Heat” to indicate that the Emergency sys-
tem is operating.
Choose the System Setting
(Cool, Off, Heat, Em, Auto)
3. Adjust temperature setting to 3° above room temperature.
Any additional stages of auxiliary heat should begin to
operate and the display will show "System On +2".
Press the SYSTEM key to select:
Cool: Thermostat controls only the cooling system.
Off: Heating and Cooling systems are off.
4. Press to adjust the thermostat below room tempera-
ture. The heating system should stop operating.
Heat: Thermostat controls only the heating system.
Em: Setting is available only when the thermostat is config-
ured in HP1 or HP2 mode.
CAUTION
!
Auto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day. AUTO allows
the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using AUTO, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.
To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate
the cooling system.
Cooling/Dehumidifier
1. Press SYSTEM to select "Cool".
2. Press
to adjust the thermostat setting below room tem-
Manual Operation for
Non-Programmable Mode
perature. The blower should come on immediately on high
speed, followed by cold air circulation. The display should
show "System On". If the setpoint temperature display is
flashing, the compressor lockout feature is operating (see
Configuration menu, item 12).
Press the SYSTEM key to select "Heat" or "Cool" and use
the keys to adjust the temperature to your desired setting.
After selecting your desired settings you can also press the
SYSTEM key to select AUTO to allow the thermostat to auto-
matically change between "Heat" and "Cool".
3. Adjust temperature setting to 3° below room temperature.
11
| General | Details |
|---|---|
| Name | COPELAND 1F95G-1235GC Humidity Universal Thermostat Instruction Manual |
| Make | Copeland |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.42 MB |

COPELAND ST55 Sensi Smart Thermostat Instruction Manual

COPELAND 1F76U-22WFB Series Sensi Lite Smart Thermostat Installation Guide

COPELAND 026-1739 Programmable Touchscreen Thermostat User Manual

COPELAND P-N 810-1600 Programmable Touchscreen Thermostat User Guide

COPELAND 1F86-0244 Blue 2 Inch Single Stage Thermostat Instruction Manual