Home > BEOK CONTROLS > beok-controls TGM50 Smart WiFi Underfloor Thermostat User Guide
beok-controls TGM50 Smart WiFi Underfloor Thermostat User Guide
Note:
02 Sensor selection:
If no external sensor is connected, do not set it to OUT or ALL,
otherwise Er will appear on the screen.And the thermostat will stop
heating till the problem is solved.
If there is error of sensor Er will also appear on the screen.
05 Antifreeze function:
If Antifreeze function is turned on,when you turn off the
thermostat,the room temperature and
key is still displayed.
11 Window opening dection:
When the window opening detection is turned on,if the room
temperature drops by 6 °C within 4 minutes,then window
opening mode will be triggered. At this time,the thermostat will
stop heating, and the window opening detection icon is
displayed.
After the window opening mode is triggered,in the following
three conditions, the mode will be exited:
1.the room temperature rises by 3 °C
2.48 minutes after triggering
3.manual
| General | Details |
|---|---|
| Name | beok-controls TGM50 Smart WiFi Underfloor Thermostat User Guide |
| Make | BEOK CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.86 MB |

BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide

BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions

BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TDR89 Thermostat User Guide

BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide

BEOK CONTROLS TGR86 WiFi Thermostat User Guide

BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual

BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual