BAXI uSense 2 Wired Smart Thermostat Gateway Installation Guide
3. Before you start
Wear appropriate Personal Protection Equipment
e.g. protective gloves, safety footwear etc.
Positioning the uSense 2:
The room unit must be positioned taking into
account the following factors:
•
•
•
•
•
•
•
On an internal wall
1.5 m
1
Away from draughts
1.2-1.5 m from the floor
Not behind doors, bookcases or other objects
Not in direct sunlight
In a room where the user spends most of their time
Away from heat sources (fireplace, radiators, light,
candles, etc.)
•
The maximum cable length from the gateway
to the room unit is 50 m
Prior to installation make sure to:
1. Isolate the power to the heating and control
system and make safe (remove or lock off fuse)
2. Check that the power has been isolated
using suitable test equipment
Warning: High Voltage wiring
must only be installed and worked
on by a suitably qualified person.
5