TH146-P USER CONSOLE  
7. Humidity Setting  
7.1 Display  
Temperature setpoint range  
Heating mode: 5°C to 30°C (40°F to 86°F)  
Cooling mode: 15°C to 40°C (59°F to 104°F)  
Humidity setpoint range: 5 to 60%  
Indoor temperature display range: 0°C to 70°C (32°F to 158°F)  
Outdoor temp. display range: -50°C to 70°C (-58°F to 158°F)  
Temperature display resolution: 0.5°C (1°F)  
Program protection: non-volatile memory  
Operating temperature: 0°C to 50°C (32°F to 122°F)  
Storage temperature: -20°C to 50°C (-4°F to 122°F)  
Humidity conditions: 0 to 95%, non-condensing  
Dimensions: 79 x 79 x 24 mm (3.1 x 3.1 x 1 in.)  
Appearswhen the  
humidity setpoint  
is displayed  
Humidifier is On  
Humidity level  
Humidity control mode  
(auto, manual or off)  
9. Warranty  
Aube warrants this product, excluding battery, to be free from defects in the  
workmanship or materials, under normal use and service, for a period of three (3)  
years from the date of purchase by the consumer. If at any time during the  
warranty period the product is determined to be defective or malfunctions, Aube  
shall repair or replace it (at Aube's option).  
7.2 Humidity Adjustment  
Manual Adjustment  
The humidity level is set by the user (5 to 60%).  
If the product is defective,  
(i) return it, with a bill of sale or other dated proof of purchase, to the place from  
which you purchased it, or  
n Press the Hum button until MAN appears on the screen.  
o Press one of the  
buttons to adjust the humidity level.  
(ii) contact Aube. Aube will make the determination whether the product should  
be returned, or whether a replacement product can be sent to you.  
This warranty does not cover removal or reinstallation costs. This warranty shall  
not apply if it is shown by Aube that the defect or malfunction was caused by  
damage which occurred while the product was in the possession of a consumer.  
Aube's sole responsibility shall be to repair or replace the product within the terms  
stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF  
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES  
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY  
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS  
PRODUCT. Some provinces and states do not allow the exclusion or limitation of  
incidental or consequential damages, so this limitation may not apply to you.  
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON  
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES,  
INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR  
DURATION OF THIS WARRANTY. Some provinces and states do not allow  
limitations on how long an implied warranty lasts, so the above limitation may not  
apply to you.  
p Press the  
Automatic Adjustment  
button.  
The humidity level is set by the controller based on the outdoor tem-  
perature to prevent ice formation or condensation on the windows  
while providing enough humidity for your comfort. However, the user  
can apply an offset (-9 to 9%). For example, the user can enter a  
negative offset if there is ice formation or condensation on the win-  
dows.  
n Press the Hum button until AUTO appears on the screen. The  
humidity level set by the controller is also displayed.  
o Press one of the  
buttons to enter or change the offset.  
p Press the  
Off  
button.  
To turn off the humidity control:  
This warranty gives you specific legal rights, and you may have other rights which  
vary by province or state.  
n Press the Hum button until OFF appears on the screen.  
o Press the  
button to save and exit the programming.  
10.Support  
If you have any questions about the product installation or  
operation, or concerning the warranty, contact us at the address  
shown below.  
8. Technical Specifications  
CT280-2H1C CONTROL MODULE  
Power supply: 24 VAC  
705 Montrichard  
Saint-Jean-sur-Richelieu, Quebec  
J2X 5K8  
10, rue Ampère  
95500 Gonesse  
France  
Current consumption: 150 mA  
Canada  
Tel: 33 (0) 1 34 07 99 00  
Fax: 33 (0) 1 34 07 99 19  
Email: advaube@comintes.com  
Maximum load per output: 1 A @ 24 VAC  
Short cycle protection: 2 minutes  
Tel: (450) 358-4600  
Toll-free: 1-800-831-AUBE  
Fax: (450) 358-4650  
Control cycles: 2 to 6 per hour  
Email: aube.service@honeywell.com  
Operating temperature: 0°C to 50°C (32°F to 122°F)  
Storage temperature: -20°C to 50°C (-4°F to 122°F)  
Humidity conditions: 0 to 95%, non-condensing  
Dimensions: 95 x 137 x 30 (3.8 x 5.4 x 1.2 in.)  
For more information on our products, visit us at:  
®
As an ENERGY STAR partner, Aube Technologies  
has determined that this product meets the  
ENERGY STAR guidelines for energy efficiency.  
TH146-P-2H1C  
400-280-014-A  
5/23/07  
11/11  
GeneralDetails
Nameaube TH146-P-2H1C Programmable Thermostat Installation Guide
Makeaube
LanguageEnglish
FiletypePDF (Download)
File size0.46 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
aube Electronic Thermostat TH131 Owner’s Manual
aube Electronic Thermostat TH131 Owner’s Manual
aube TH114-AF-GA Non-Programmable Thermostat Owner’s Manual
aube TH114-AF-GA Non-Programmable Thermostat Owner’s Manual

aube TH146-P-2H1C Programmable Thermostat Installation Guide