TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS (S86N MUPR ONLY)
TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS (S86N MUPR ONLY)
System
setting
Factory default setting
(bold) and setting range
System
setting
Factory default setting
(bold) and setting range
Description
Description
Manual adjustment of Calculated Minutes per
Hourꢀ
(Calculated Minutes per Hour)
Range 6 to 60 Minutes
NOTE: Ventilation can only be installed if humidification is not enabled and dehumidifier
control is not set to Whole Home.
Override
Outdoor
Fresh Air Vent
Installed?
Selects if ventilation is installedꢀ (If set to No, no
No
other ventilation settings will be availableꢀ)
Yes
Remote
(Onboard sensor disabled)
Wired
Selects how the external temperature sensor
terminals (T1 & T2) are being usedꢀ Choose
Outdoor for a wired outdoor sensor or Remote/
Remote Average for a wired indoor sensorꢀ
Selects if ventilation is configured through the
Code setup or Comfortꢀ Comfort setup has
more lockout optionsꢀ Code setting ensures
time missed due to lockouts is made upꢀ
Temperature
Sensor
Remote Average
(Average with onboard sensor)
Fresh Air
Setup Type
Comfort
Code
Installed?
No
(No external sensor connected)
Number of
Bedrooms
Selects the number of bedrooms to be used for
the Calculated Minutes per Hourꢀ
3 Bedrooms
1 to 10 Bedrooms
Selects if ventilation is disabled when the
indoor RH exceeds the indoor RH limitꢀ (Only
available if Fresh Air Setup is set to Comfortꢀ)
High Vent RH
Limit
Disabled
Enabled
Square
Footage
Selects the size of the home to be used for the
Calculated Minutes per Hourꢀ
2500 SQ FT
500 to 7500 SQ FT
High Vent RH
Limit
Sets the ventilation indoor RH lockout limitꢀ (Only
available if High Vent RH Limit is set to Enabledꢀ)
55%
45% to 70%
Measured
CFM
Selects the ventilation CFM to be used for the
Calculated Minutes per Hourꢀ
110 CFM
30 to 250 CFM
Selects if ventilation is disabled when the
indoor RH exceeds the indoor RH limitꢀ (Only
available if Fresh Air Setup is set to Comfortꢀ)
Low Vent RH
Limit
Disabled
Enabled
Calculated
Minutes Per
Hour
None
Displays the Fresh Air Time calculatedꢀ
Range 6 to 60 Minutes
32
33
| General | Details |
|---|---|
| Name | Aprilaire S86N MU Multi Stage Universal Thermostat Instruction Manual |
| Make | Aprilaire |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.37 MB |

Aprilaire 8570 Premium Programmable Thermostat Instruction Manual

Aprilaire 8538 Digital Heat Cool Thermostat Owner’s Manual

AprilAire S86W MUPR WiFi Thermostat User Guide

Aprilaire S86WMUPR Programmable Wi-Fi Multi Stage Universal Thermostat Installation Guide

Aprilaire S86N MUPR Multi Stage Universal Thermostat Owner’s Manual

Aprilaire S84N 1H1C Programmable Single Stage Universal Thermostat Owner’s Manual