Home > Sygonix > sygonix 2735095 Wireless Heating Thermostat Instruction Manual

sygonix 2735095 Wireless Heating Thermostat Instruction Manual

Please handle the product carefully. Jolts, impacts or a fall even from a low height can  
damage the product.  
Consult a technician when in doubt about the operation, safety or connection of the ap-  
pliance.  
Operating instructions  
Wireless heating thermostat  
If you have questions which remain unanswered by these operating instructions, contact  
our technical support service or other technical personnel.  
Item no. 2735095  
5.2 Installation/connection  
Caution, safety hazard!  
1 Intended use  
The product should only be installed and connected by people with relevant  
electrical knowledge and experience! *)  
This product is a wireless heating thermostat intended for temperature control and can be  
integrated into an electric heating system, such as floor heating or panel radiators.  
If the product is not installed properly, you risk:  
You can schedule the room temperature precisely to the hour to suit your individual needs.  
You can programme the room temperature for 7 days in advance. With six programmable time  
settings a day, you can reduce your heating costs and adjust the temperature in your home to  
your needs. You can save on heating costs when you are on holiday or away on business. The  
holiday mode keeps the temperature in your home constant at a preset level.  
your own life;  
the life of the person using the electrical device.  
If the product is not installed properly, you risk severe damage to property, e.g. due to fire. You  
face the risk of personal liability for personal injury and material damage.  
The wireless heating thermostat is powered by two Mignon batteries (AA). The switching re-  
ceiver is connected directly to the mains voltage. You can also connect a consumer operated  
via the mains voltage supply to the switching receiver and switch it on or off through tempera-  
ture control.  
Always consult an electrician!  
*) Technical knowledge required to perform the installation!  
The following specialist knowledge is required for installation:  
The “Five Safety Rules”: Disconnect from the mains; protect against accidental switch-on;  
ensure there is no voltage; earth and short-circuit; cover or protect adjacent live parts.  
The heating thermostat has a built-in temperature sensor (probe) and allows connecting an  
external sensor to the switching module. The product has a button lock feature that prevents  
incorrect operation and a permanently installed decoupling capacitor for data backup in the  
event of a power failure. This device has an IP20 ingress protection rating and is suitable for  
dry rooms and indoor use. Do not use it outdoors. Contact with moisture, e.g. in bathrooms,  
must be avoided under all circumstances.  
Use of suitable tools, measuring devices and personal protective equipment, where neces-  
sary.  
Analysis of measurement results.  
Use of electrical installation materials to meet the requirements for safe disconnection from  
the power supply.  
For safety and approval purposes, do not rebuild and/or modify this product. If you use the  
product for purposes other than those described above, the product may be damaged. In addi-  
tion, improper use can result in short circuits, fires, electric shocks or other hazards. Read the  
instructions carefully and store them in a safe place. Make this product available to third parties  
only together with its operating instructions.  
IP protection ratings.  
Installation of electrical installation materials.  
Type of power supply (TN system, IT system, TT system) and the corresponding con-  
nection criteria (classic earthing, protective earthing, necessary additional measures, etc.)  
This product complies with the statutory national and European requirements. All company and  
product names contained herein are trademarks of their respective owners. All rights reserved.  
If you do not have sufficient knowledge in all of the aforementioned topics, contact a specialist  
and do not attempt to install or connect the product yourself.  
2 Delivery content  
Further warnings:  
Radio room thermostat  
4x Screw  
The construction of the product corresponds to the protection-class II (double or re-  
Switching module  
Operating instructions  
inforced isolation). Ensure that the insulation of the housing is neither damaged nor  
destroyed.  
3 Up-to-date operating instructions  
Download the latest operating instructions at www.conrad.com/downloads or scan the QR code  
shown. Follow the instructions on the website.  
Before installing the switching module, disconnect all poles from the mains voltage  
using a residual current device (RCD). There must be an appropriately rated fuse or  
circuit breaker between the RCD and the product.  
The device must be de-energised during installation and connection of the switching  
4 Description of symbols  
module. Furthermore, turn off the automatic circuit breaker and the RCD to disconnect  
all poles from the mains voltage. Secure it against unauthorised reconnection, e.g.  
with a warning sign. Then check to ensure there is no voltage with a suitable measu-  
ring device (e.g. a two-pole voltage tester).  
This symbol warns of dangerous voltage that can lead to injury from electric shock.  
Read the information carefully.  
The symbol with the exclamation mark in the triangle indicates important information  
in this document. Always read this information carefully.  
Never connect the product to the power supply immediately after it has been transfer-  
red from a cold room into a warm one (e.g., during transport). The condensation that  
forms may destroy the device. Moreover, there is danger of electric shock!  
The product should only be used in dry, indoor locations. It must not get damp or  
wet.  
Always let the product reach room temperature first. Wait until the condensation has  
evaporated. In some cases, this may take several hours. Only once the condensation  
has evaporated should it be installed, connected to the power supply and put into use.  
The product is designed according to protection Class II (reinforced or double insu-  
lation, protective insulation).  
Do not use the product in rooms with adverse environmental conditions, where com-  
bustible gases, vapours or dust are or may be present! This may cause an explosion!  
Pay attention to the operating instructions!  
5.3 Protection class  
5 Safety instructions  
This device has an IP20 ingress protection rating and is suitable for dry rooms.  
Read the operating instructions carefully and adhere in particular to the safety  
instructions. If you do not heed the safety instructions and information on  
proper handling in these operating instructions, we will assume no liability  
for any resulting personal injury or property damage. Such cases will also  
invalidate the warranty/guarantee.  
There is protection against touching live components and ingress from foreign particles  
>12.5 mm.  
There is no protection against water, combustible gases, and vapours.  
5.1 General information  
This product is not a toy. Keep it out of the reach of children and pets.  
Do not leave packaging material lying around carelessly, as it could become a dangerous  
plaything for children.  
Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity,  
moisture, flammable gases, vapours and solvents.  
Do not expose the product to any mechanical stress.  
If it is no longer possible to operate the product safely, take it out of operation and protect  
it from any accidental use. Safe operation can no longer be guaranteed if the product:  
is visibly damaged,  
is no longer working properly,  
has been stored for extended periods in poor ambient conditions or  
has been subjected to any serious transport-related stress.  
1
GeneralDetails
Namesygonix 2735095 Wireless Heating Thermostat Instruction Manual
MakeSygonix
LanguageEnglish
FiletypePDF (Download)
File size0.79 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
sygonix SY-5470190 Wireless Indoor Thermostat Instruction Manual
sygonix SY-5470190 Wireless Indoor Thermostat Instruction Manual
Sygonix 2992337 DIN Rail Mounted Heating And Cooling Thermostat User Manual
Sygonix 2992337 DIN Rail Mounted Heating And Cooling Thermostat User Manual
sygonix 3026090 WiFi Thermostat Installation Guide
sygonix 3026090 WiFi Thermostat Installation Guide
Sygonix SY-6052180 Wi-Fi Thermostat Instruction Manual
Sygonix SY-6052180 Wi-Fi Thermostat Instruction Manual
sygonix 2522212 Installable Thermostat Instruction Manual
sygonix 2522212 Installable Thermostat Instruction Manual
Sygonix 2735095 Wireless Indoor Thermostat Instruction Manual
Sygonix 2735095 Wireless Indoor Thermostat Instruction Manual
sygonix 2997033 Wi-Fi Radiator Thermostat Instruction Manual
sygonix 2997033 Wi-Fi Radiator Thermostat Instruction Manual

sygonix 2735095 Wireless Heating Thermostat Instruction Manual
Get the free PDF manual for the sygonix 2735095 Wireless Heating Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

sygonix 2735095 Wireless Heating Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product. Consult a technician when in doubt about the operation, safety or connection of the appliance. This product is a wireless heating thermostat intended for temperature control and can be integrated into an electric heating system. You can schedule the room temperature precisely to the hour to suit your individual needs. The wireless heating thermostat is powered by two Mignon batteries (AA). The product has a button lock feature that prevents incorrect operation. This device has an IP20 ingress protection rating and is suitable for dry rooms and indoor use. The product should only be installed and connected by people with relevant electrical knowledge and experience. Read the instructions carefully and store them in a safe place. If you do not have sufficient knowledge in all of the aforementioned topics, contact a specialist and do not attempt to install or connect the product yourself.
  • Page 2: Icons indicate various statuses of the wireless thermostat and switching module. The wireless thermostat has modes for auto, manual, and holiday settings. The switching module includes functions for setting time, day, and advanced options. Power indicators show the status of the device, including load and fault lights. Installation involves connecting the mains power supply and consumer devices correctly. The display shows programmable periods and current temperature settings. The thermostat should be mounted approximately 1.5 meters above floor level. Connection cables must be protected from sharp edges and should not be fastened with nails or screws. Button lock can be enabled or disabled with a specific button press. The thermostat is ready for use after replacing the front panels and turning on the mains voltage.
  • Page 3: Programming the weekly schedule involves configuring temperature settings for six time periods throughout the day. You can turn the wireless heating thermostat on and off using the designated button. When the thermostat is off, the display goes out and no temperature control occurs. Default times and temperatures for each period are provided. To set the time and weekday, ensure the thermostat is in normal status. You can choose between different weekday intervals for programming. Switching between automatic and manual mode is done through specific button presses. Parental control lock can be activated or deactivated through the settings menu. Holiday mode allows you to set a time and temperature for the days you will be away. Adjusting system settings may lead to unexpected behavior, so instructions should be followed carefully.
  • Page 4: Display code factory default System settings calibration temperature deviation Adjustment range -9 to +9 °C Switching differential (hysteresis) An error code will show if there is a problem with the internal or external sensor. Set the lowest selectable temperature. The heater will turn on automatically if the sensor measures the temperature below the preset value. This product does not require maintenance. Use a dry, soft, lint-free cloth to wipe the panel. After the thermostat has been successfully reset to factory defaults, it switches off.
  • Page 5: Disposal This symbol must appear on any electrical and electronic equipment placed on the EU market. This symbol indicates that this device should not be disposed of as unsorted municipal waste at the end of its service life. Owners of WEEE shall dispose of it separately from unsorted municipal waste. Spent batteries and accumulators must be removed by end users from the WEEE in a non-destructive manner before it is handed over to a collection point. Distributors of electrical and electronic equipment are legally obliged to provide free take-back of waste. End users are responsible for deleting personal data from the WEEE to be disposed of. Different obligations about the return or recycling of WEEE may apply in countries outside of Germany. Batteries/rechargeable batteries Remove batteries/rechargeable batteries, if any, and dispose of them separately from the product. According to the Battery Directive, end users are legally obliged to return all spent batteries/rechargeable batteries; they must not be disposed of in the normal household waste. Batteries/rechargeable batteries containing hazardous substances are labelled with this symbol to indicate that disposal in household waste is forbidden. Used batteries can be returned to collection points in your municipality, our stores or wherever batteries are sold. Batteries that are disposed of should be protected against short circuit and their exposed terminals should be covered completely with insulating tape before disposal. Technical data Rated voltage for the thermostat is 3 V, 2x Mignon batteries (AA). The protection rating is IP20 with a temperature adjustment range of +1 to 70 °C. The thermostat dimensions are 86 x 86 x 30 mm and it weighs 120 g (without batteries). The switching module has a rated voltage of 90 to 240 V/AC, 50/60 Hz, with a maximum connected load of 3000 W (resistive load). The protection rating is IP20 and the dimensions are 86 x 86 x 29 mm, weighing 125 g.