Commissioning  
D
9. Commissioning  
1 Appliance  
2 Wall mounted enclosure  
3 6-pole socket plug  
9.1 Appliance handover  
f Explain the appliance function to users and familiarise them  
f Connect the bus cable to the female connector.  
with how it works.  
6-pole socket plug  
1
2
3
4
5
6
Not assigned  
Not assigned  
GND  
Note  
Hand over these operating and installation instructions to  
users for safe-keeping. All information in these instruc-  
tions must be closely observed. The instructions provide  
information on safety, operation, installation and main-  
tenance of the appliance.  
+5 V DC  
SDA  
SCL  
f Connect the female connector to the back of the appliance.  
10. Specification  
Completing the installation  
f Carefully push the unit into the wall mounted enclosure until  
10.1 Dimensions  
it engages.  
J
8.2 Installation as a spare part in the ventilation  
unit  
10.2 Data table  
f Disconnect the power supply by pulling the power plug from  
FEB 2.1  
its socket.  
206612  
5
Operating voltage  
Height  
Width  
V
mm  
mm  
mm  
E
96  
145  
31  
f To release the filter cover, press the cover fastening on both  
sides of the appliance.  
Depth  
f Pull the filter cover forwards to remove it from the appliance.  
F
f From above, undo the screws securing the top front panel to  
the ventilation unit.  
G
A cable is connected at the back of the programming unit.  
f To avoid damaging the cable and programming unit, lift the  
top front panel carefully off the ventilation unit.  
Guarantee  
H
The guarantee conditions of our German companies do not  
apply to appliances acquired outside of Germany. In countries  
where our subsidiaries sell our products a guarantee can only  
be issued by those subsidiaries. Such guarantee is only grant-  
ed if the subsidiary has issued its own terms of guarantee. No  
other guarantee will be granted.  
f Disconnect the cable from the back of the programming unit.  
I
f At the back of the programming unit, press the side locking  
tabs inwards and remove the frame from the programming  
unit.  
We shall not provide any guarantee for appliances acquired in  
countries where we have no subsidiary to sell our products.  
This will not affect warranties issued by any importers.  
f Place the new programming unit into the top front panel  
from the front.  
f Fit the frame on the back of the programming unit.  
Environment and recycling  
f Dispose of the appliances and materials after use in accor-  
dance with national regulations.  
f Press carefully on the programming unit until it clicks into  
place in the frame.  
f Insert the cable into the slot at the back of the programming  
unit.  
f If a crossed-out waste bin is pictured on the ap-  
pliance, take the appliance to your local waste  
and recycling centre or nearest retail take-back  
point for reuse and recycling.  
f Fit the top front panel to the ventilation unit.  
This document is made of recyclable paper.  
f Dispose of the document at the end of the ap-  
pliance‘s life cycle in accordance with national  
regulations.  
FEB 2.1|11  
GeneralDetails
NameSTIEBEL ELTRON FEB 2.1 Programming Thermostat Installation Guide
MakeSTIEBEL ELTRON
LanguageEnglish
FiletypePDF (Download)
File size2.08 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Stiebel Eltron RTA-3000 S2 Thermostat Installation Guide
Stiebel Eltron RTA-3000 S2 Thermostat Installation Guide

STIEBEL ELTRON FEB 2.1 Programming Thermostat Installation Guide