Home > StelPro > STELPRO ST252NPFF Non-Programmable Electronic Thermostat for Fan Heaters Owner’s Manual
STELPRO ST252NPFF Non-Programmable Electronic Thermostat for Fan Heaters Owner’s Manual
OWNER’S MANUAL
INSTALLATION
INSTALLATION – CONT’D
INITIAL SETTINGS
To begin with, follow the on-screen instructions to adjust your
thermostat’s settings. Press
and to confirm.
or
to change your selection
ATTACH THE MOUNTING PLATE
ATTACH THE THERMOSTAT
1
3
1. Temperature format: °C / °F (Celsius / Fahrenheit)
2. ECO mode setpoint temperature (5°C to 30°C / 41°F to
86°F). By default, the ECO mode setpoint is 17°C / 63°F.
NON-PROGRAMMABLE ELECTRONIC THERMOSTAT
FOR FAN HEATERS
1. Using the alignment guide, hook the bottom [A] of the
thermostat into the bottom of the plate. Be sure not to jam
the wires between the thermostat and mounting plate.
WARNING
Turn off the power supply.
Your heating needs may vary according to the season
and even the time of day. To meet your needs, this
thermostat is equipped with two distinct modes: ECO
and COMFORT. You can switch from one mode to
ST252NPFF
ST402NPFF
2. Rotate the thermostat upwards [B] and attach it on the top
hook of the mounting plate.
1-844-STELPRO
WWW.STELPRO.COM
3. Tighten the screw at the top of the thermostat [C] to hold
it in place securely.
1. Loosen the screw [A] at the top of the thermostat [B]
without removing it.
another by simply pressing
. ECO mode saves you
money by providing a more energy-efficient setpoint
temperature when you’re sleeping or away from home.
4. Restore the power at the circuit breaker.
2. Separate the mounting plate [C] from the thermostat.
Pull the top of the plate and rotate it as shown.
3. Take the power wires [D] out of the junction box [E] and
run them through the large opening in the center of the
mounting plate [F].
IMPORTANT INSTRUCTIONS
3. Lobby mode: Std / Lby (Standard room / Lobby).
THE THERMOSTAT MUST BE INSTALLED BY A CERTIFIED
ELECTRICIAN.
In Lobby mode, the thermostat automatically provides
100% heating for five minutes as soon as a sudden drop
in temperature is detected. This mode can be useful for
heaters located near an entrance. When this mode is
4. Using the two (2) mounting screws provided [G], attach
the thermostat mounting plate to the junction box [E]. The
plate can be centered on the junction box or shifted to the
left or right.
B
C
Connect the thermostat to a 120 to 240 VAC power source ONLY and
comply with load limits.
activated, the
icon flashes.
WARNING – HIGH VOLTAGE
D
A
YOUR THERMOSTAT IS NOW READY TO USE!
A
Turn off the power supply before installation and main-
tenance. Leave at least 12 in. (30 cm) clearance around
the thermostat to ensure that it is properly vented.
C
B
F
FEATURES
SAVE THESE INSTRUCTIONS
G
NOTE: If you need to remove the thermostat, follow step 1 in
section 1, then use a straight screwdriver to unhook it from the
top of the mounting plate.
KEY FEATURES
TECHNICAL SPECIFICATIONS
1. Press
or once to lower or raise the setpoint
temperature by 0.5°C / 1°F. The setpoint temperature
E
will remain at this value until it is changed. Note: If you
change the setpoint temperature while in ECO mode, the
thermostat will switch to COMFORT mode.
VOLTAGE AND LOAD
PRODUCT CODE
SUPPLY VOLTAGE
LOAD AT 120 V
LOAD AT 240 V
VOLTS
WATTS
WATTS
INTERFACE
2. Press
mode and vice versa.
once to switch from ECO mode to COMFORT
ST252NPFF
ST402NPFF
150-1250
150-2000
300-2500
300-4000
CONNECT THE POWER
SUPPLY WIRES
120-240
2
3. Press and simultaneously to activate BOOST mode
. Then, press or to select BOOST mode duration
(10, 20, 30, 40, 40, 50 or 60 minutes). The thermostat will
then heat at 100% for the time specified.
This is a non-programmable thermostat. The temperature
setpoint remains constant unless you change it.
Load control type
Frequency
Resistive
60 Hz
Storage temperature
-40°C to 50°C (-40°F to 122°F)
-20°C to 50°C (-4°F to 122°F).
LC display less effective below 0°C (32°F)
1. Complete the thermostat’s electrical connection according
to the diagram below. Tighten the wires securely in the
supplied wire connectors.
Operating temperature
ADVANCED MENU ACCESS AND USE
Heating output
Humidity
5% to 98% without condensation
1. Press and hold
thermostat’s advanced menus.
for three (3) seconds to access the
2. Push the wires and connectors into the electrical box.
Action
Type 1.Y
Pollution degree
Software
2
Fan mode
(LOBBY mode is
activated when
Keypad
locked
2. Press
or to change your selection.
Class A
Rated impulse voltage
Category II overvoltage (1500 V)
BLACK
ER
LOAD
3. Press
next menu.
to confirm your selection and proceed to the
flashing)
Independently mounted control for surface mounting
Thermistor used as a sensor, carries no load current
Ambient
temperature/
contextual
4. Press and hold
advanced menus.
for three (3) seconds to exit the
Overload protection device external to the control: circuit breaker
(refer to local electrical code)
information
Menu
indicator
ADVANCED MENUS LIST
Current
menu*
ECO mode
indicator
• Menu 10 – Temperature format: °C / °F (Celsius /
Fahrenheit)
°STELPRO LIMITED WARRANTY
• Menu 20 – ECO mode setpoint temperature (5°C to 30°C /
41°F to 86°F). By default, the ECO mode setpoint is 17°C
/ 63°F.
Keypad
RED
YELLOW
• Menu 30 – Lobby mode: Std / Lby (Standard room / Lobby)
• Menu 40 – Keypad lock: ON / OFF (Lock / Unlock keypad)
• dEF – Reset thermostat to default values: N / Y (No / Yes)
The diagram shows a 240 V power supply.
BEFORE YOU GET STARTED
• The box contains one (1) thermostat with mounting plate,
two (2) mounting screws, three (3) twist-on wire connectors
and one (1) owner’s manual.
WARNING
Incorrectly connected electrical
*Displays only when using the advanced menus.
wires could result in a fire hazard.
• To install this thermostat, you will need a #2 Phillips screw-
driver.
Touch the keypad once to activate the backlight, then you
can make changes.
NOTE: If the electrical wires are aluminum, use CO/ALR
connectors instead (not supplied).
• Install your thermostat about 5 ft (1.5 m) from the floor on
an inside wall facing the heating system.
Saint-Bruno-de-Montarville, Quebec,
Canada, J3V 6L7
STELPRO DESIGN INC.
EN1
EN2
EN3
EN4
| General | Details |
|---|---|
| Name | STELPRO ST252NPFF Non-Programmable Electronic Thermostat for Fan Heaters Owner’s Manual |
| Make | StelPro |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.25 MB |

STELPRO STF362NP Floor Heating Thermostat Owner’s Manual

STELPRO ST302P Programmable Electronic Thermostat Owner’s Manual
STELPRO SAT402ZB Smart Thermostat User Guide

STELPRO ST252NPFF Non-Programmable Electronic Thermostat Owner’s Manual

STELPRO ST402PFF Programmable Electronic Thermostat Owner’s Manual

STELPRO ASMC402 Maestro Zigbee Smart Programmable Thermostat User Guide

STELPRO SIBTE12C Electronic Thermostat Owner’s Manual

STELPRO STZW402+ Electronic Thermostat for The Smart Home Owner’s Manual

STELPRO SIBTE13F Electronic Thermostat User Guide

STELPRO STCP MULTIPLE PROGRAMMING ELECTRONIC THERMOSTAT User Guide

STELPRO ST252NPFF Non-Programmable Electronic Thermostat for Fan Heaters Owner’s Manual Overview
Summary of Contents
- Page 1: owner’s manual installation initial settings To begin with, follow the on-screen instructions to adjust your thermostat’s settings. Temperature format: °C / °F (Celsius / Fahrenheit). ECO mode setpoint temperature (5°C to 30°C / 41°F to 86°F). By default, the ECO mode setpoint is 17°C / 63°F. The thermostat must be installed by a certified electrician. In Lobby mode, the thermostat automatically provides 100% heating for five minutes as soon as a sudden drop in temperature is detected. This is a non-programmable thermostat. The temperature setpoint remains constant unless you change it. Complete the thermostat’s electrical connection according to the diagram below. Limited three-year warranty. See details on the manufacturer's website. Incorrectly connected electrical wires could result in a fire hazard.