Use  
Applications  
Room temperature control (heating or cooling) in individual rooms and zones by means of:  
2-pipe fan coil units  
2-pipe fan coil units with electric heater  
4-pipe fan coil units  
The room thermostat controls:  
One ECM fan  
One or two on/off valve actuators  
One on/off valve actuator and one 1-stage electric heater  
One 3-position valve actuator  
One 1-stage compressor with electric heater  
Used in systems with:  
Heating or cooling  
Automatic heating/cooling changeover  
Manual heating/cooling changeover  
Heating and cooling (e.g. 4-pipe system)  
The room thermostat is delivered with a fixed set of applications.  
The relevant application is selected and activated during commissioning using one of the  
following tools:  
Local DIP switch and HMI  
Modbus commissioning tools  
Functions  
Maintain room temperature via built-in temperature sensor or external room  
temperature/return air temperature sensor  
Changeover between heating and cooling mode (automatic changeover via local  
sensor/bus or manual changeover via buttons)  
Select application via DIP switches or commissioning tools  
Select operating mode via operating mode button on the thermostat  
ECM fan control (automatic or manual)  
Display current room temperature or setpoint in °C and/or °F  
Minimum and maximum limitation of room temperature setpoint  
Key lock (automatic, manual or via bus)  
B1 input freely selectable for (RDF660MB/MM only):  
External room temperature sensor or return air temperature sensor  
Automatic heating/cooling changeover sensor  
S1 input freely selectable for (RDF660MB/MM only):  
Window contact  
Presence detector  
Hotel keycard  
2 multifunctional inputs (X1 and X2), freely selectable for (RDF660MB only):  
External room temperature sensor or return air temperature sensor (AI)  
Automatic heating/cooling changeover sensor (AI)  
Window contact (DI)  
Dew point sensor (DI)  
2
Siemens  
A6V12005486_en--_d  
2022-11-14  
Smart Infrastructure  
GeneralDetails
NameSIEMENS RS485 Flush Mounted Room Thermostat User Manual
MakeSIEMENS
LanguageEnglish
FiletypePDF (Download)
File size1.07 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual
SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual
SIEMENS RDG400 Room Thermostat Instruction Manual
SIEMENS RDG400 Room Thermostat Instruction Manual
SIEMENS M3182 Room Thermostat Instruction Manual
SIEMENS M3182 Room Thermostat Instruction Manual
SIEMENS RDS120-B Smart Thermostat Instructions
SIEMENS RDS120-B Smart Thermostat Instructions
SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual
SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual
SIEMENS RDY2000BN BACnet Commercial Thermostat User Manual
SIEMENS RDY2000BN BACnet Commercial Thermostat User Manual
SIEMENS RDH100RF/SET Room Thermostat Instruction Manual
SIEMENS RDH100RF/SET Room Thermostat Instruction Manual
SIEMENS RDH100RF/SET Wireless Room Thermostat with LCD User Guide
SIEMENS RDH100RF/SET Wireless Room Thermostat with LCD User Guide
SIEMENS RDG260KN Room Thermostat Instruction Manual
SIEMENS RDG260KN Room Thermostat Instruction Manual
SIEMENS RDF660MB Flush Mount Room Thermostat Instruction Manual
SIEMENS RDF660MB Flush Mount Room Thermostat Instruction Manual

SIEMENS RS485 Flush Mounted Room Thermostat User Manual