SALUS CONTROLS RT520 Thermostat User Manual
2.5 Connection description
I A - Boiler connection
RT520
RT520
NC
COM
NO
3V
2 x AA
3V
2 x AA
A
B
(ON / OFF)
OpenTherm
I B - Pump / Valve connection
AC 230V
L
RT520
NC
COM
NO
3V
2 x AA
lub
MAX
3 (1) A
N
I C - KL08NSB underfloor heating wiring center connection
Eg.
RT520
Eg.
RT520
Eg.
RT520
COM NO
COM NO
COM NO
KL08NSB
L
N
SL
L
N
SL
L
N
SL
or
lub
1 - 8 Zones
1 - 8 Zones
1 - 8 Zones
Power
Pump
Boiler
BOILER CONNECTION*
L
N
L
N
L
N
L
N
1
2
3
4
max 6
per zone
max 6
per zone
max 6
per zone
T30NC
T30NC
T30NC
AC 230V
L
N
Legend:
Symbols explanation:
Boiler - Boiler connection*
- Boiler’s contacts for ON/OFF
thermostat (according to the
boiler’s instructions)
L, N - power supply 230V
NO, COM, NC - voltage-free output
A, B - OpenTherm Communication Wire
SL - 230V AC voltage output
- NSB function
Pump
Valve
M
- fuse
8
| General | Details |
|---|---|
| Name | SALUS CONTROLS RT520 Thermostat User Manual |
| Make | SALUS CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.9 MB |

SALUS CONTROLS IT800WIFI Smart Thermostat Installation Guide

SALUS CONTROLS IT800 WIFI Smart Thermostat Instruction Manual

SALUS CONTROLS SQ610 Quantum Smart Thermostat User Guide

SALUS CONTROLS BTR230 Non Programmable Thermostat User Guide

SALUS CONTROLS HTR-RF Smart Home Dial Thermostat User Guide

SALUS CONTROLS IT700 Smart Thermostat Instruction Manual

SALUS CONTROLS 091FLv2 Digital Programmable Thermostat Instruction Manual

SALUS CONTROLS RT200 Electronic Room Thermostat Instruction Manual

SALUS CONTROLS T105 Digital Programmable Thermostat User Guide