PRO1 T751i Thermostat Installation Guide
Product Installation Guide
Installation Tips
Wall Installation
The thermostat should be installed approximately 4 to 5 feet above the floor.
Select an area with average temperature and good air circulation. Pick an
installation location that is easy for the user to access. The temperature of the
location should be representative of the building.
T751i
Pro1 Technologies
P.O. Box 3377
Springfield, MO 65808-3377
Do not install
thermostat in locations:
Toll Free : 888-776-1427
Hours of Operation: M-F 9AM - 6PM EST
• Close to hot or cold air ducts
• That are in direct sunlight
• With an outside wall behind the
thermostat
• In areas that do not require
conditioning
• Where there are dead spots or
drafts (in corners or behind doors)
• Where there might be concealed
chimneys or pipes
PM-T751i-IM-2403
*PM-T751i-IM-2403*
Power Type
Thermostat Application Guide
Hardwire (24V Common Wire)
Description
Gas or Oil Heat
Yes
Yes
Yes
Yes
A trained, experienced
technician must install this product.
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Carefully read these
instructions. You could damage this
product or cause a
hazardous condition if you fail to
follow these instructions.
Yes
Yes
Yes
Heat Only Systems
Cool Only Systems
No
Millivolt
Removing The Private Label Badge
Una version en espanol de este
manual se puede descargar en la
pagina web de la compania.
Gently slide a screwdriver into the
bottom edge of the badge. Gently
turn the screwdriver counter
clockwise. The badge is held on by
a magnet in the well of the battery
door. The badge should pry off easily.
Table of Contents
Page
Installation Tips
Thermostat Quick Reference
Subbase Installation
Wiring
Technician Setup
WIFI Setup
Specifications
2
3
4
5-7
8-12
13
14
WIFI
Frequency Range............2.4 Ghz ISM radio band
WIFI Module...............................Supporting 802.11
B/G/N Standards
Use the bevel on lower ridge
DO NOT USE FORCE.
All of our thermostats use the same
universal magnetic badge. Visit the
company website to learn more about
our free private label program.
Magnet in door
U.S. Registered Trademark. Patents pending
Copyright 2024 All Rights Reserved.
1
2
Rev. 2403
Thermostat Quick Reference
Subbase Installation
Horizontal Mount
For horizontal mount put one
screw on the left and one screw
on the right.
LCD Display
Glow in the dark light button
Fan Button
Vertical Mount
For vertical mount put one
screw on the top and one screw
on the bottom.
System Button
Temperature Setpoint Buttons
Private Label Badge
Electrical Hazard
Failure to disconnect the power before
beginning to install this product can cause
electrical shock or equipment damage.
Set At
COOL ON
HEAT ON
FAN ON
Mercury Notice
NOTE: To ensure a solid fit between
the thermostat and subbase:
1. Mount subbase on a flat wall.
2. Use provided screws.
All of our products are mercury free.
However, if the product you are replacing
contains mercury, dispose of it properly.
Your local waste management authority
can give you instructions on recycling and
proper disposal.
3. Ensure drywall anchors are flush with wall.
4. Push wires into wall.
Em.Heat
STAGES AutoCool
Mount Thermostat
Indicates the current room temperature
1
2
3
Setpoint: Displays the selected setpoint temperature.
System Operation Indicators: The COOL ON, HEAT ON or FAN ON will display
when the COOL, HEAT, or FAN is on. The compressor delay feature is active if these
are flashing.
Align the 4 tabs on the subbase
with corresponding slots on the
WIFI Indicator: Shown when connected to WiFi.
back of the thermostat, then push
gently until the thermostat snaps
in place.
Globe: Globe is displayed if an energy efficient setpoint temperature has been
selected.
Fan: Indicates the current fan setting.
Stages: 1 will appear in the display when the first stage of heat or cool is on.
+2 will appear for the second stage of heat.
7
System: Indicates current system mode setting.
4
| General | Details |
|---|---|
| Name | PRO1 T751i Thermostat Installation Guide |
| Make | PRO1 |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.3 MB |

PRO1 T731W Wireless PTAC Non-Programmable Thermostat Installation Guide

PRO1 T805 Non Programmable Thermostat Instruction Manual

PRO1 T701 Digital Non Programmable Thermostat Instruction Manual

PRO1 IAQ T721i Digital WIFI Programmable Thermostat User Manual

PRO1 R250W Wireless System Thermostat Owner’s Manual

PRO1 T725 Thermostat User Guide

PRO1 T755 Heat 2 Cool Dual Fuel Thermostat User Manual

PRO1 T771 Programmable Electronic Thermostat Instructions

PRO1 T751i Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Product installation guide The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation. Do not install thermostat in locations close to hot or cold air ducts, in direct sunlight, with an outside wall behind the thermostat, in areas that do not require conditioning, where there are dead spots or drafts, or where there might be concealed chimneys or pipes. A trained, experienced technician must install this product. Carefully read these instructions to avoid damaging the product or causing a hazardous condition. Gently slide a screwdriver into the bottom edge of the badge to remove it. All of our thermostats use the same universal magnetic badge. Failure to disconnect the power before beginning to install this product can cause electrical shock or equipment damage. All of our products are mercury free, but if the product you are replacing contains mercury, dispose of it properly. Ensure drywall anchors are flush with the wall before mounting the subbase.
- Page 2: Wiring Power supply Factory-installed jumper, remove only when installing on 2-transformer system. A 24 VAC 500mA common connection is required with this thermostat. Devices such as a float switch that mechanically break circuits should be installed so that they break the control wire (Y) not the power (R). Do not overtighten terminal block screws, as this can damage the terminal block. Electrical hazard: Failure to disconnect the power before beginning to install this product can cause electrical shock or equipment damage. This thermostat has a technician setup menu for easy installer configuration. All components of the control system and the thermostat installation must conform to Class II circuits per the NEC Code. This thermostat requires a 24V common wire to the C terminal. The compressor short cycle delay protects the compressor from short cycling.
- Page 3: Technician Setup Menu Tech Settings Adjustment Options This setting allows you to select the number of heat and cool stages. The swing setting is adjustable from 0.2˚ to 2˚. Note: Heat and cool choices are limited based on conventional, heat pump, or PTAC system configuration. This setting allows the thermostat to operate a PTAC. This setting allows you to choose the number of fan speeds the thermostat will control. This setting will select the terminal for medium fan speed operations. This feature allows the thermostat to keep multiple stages of heat or cool energized until the setpoint is satisfied. You can set the minimum compressor run time to “OFF”, “3”, “4”, or “5” minutes. You can configure this thermostat to have a programmable schedule ON or OFF.
- Page 4: WIFI setup instructions are provided for viewing information and resetting your WIFI connection, which are not typically necessary for installation or initial setup. The display range of temperature is 41˚F to 95˚F (5˚C to 35˚C). The control range of temperature is 44˚F to 90˚F (7˚C to 32˚C). The load rating is 1 amp per terminal, with a maximum of 1.5 amps for all terminals combined. The power source required is 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire. The operating ambient temperature range is 32˚F to +105˚F (0˚C to +41˚C). The operating humidity maximum is 90% non-condensing. The dimensions of the thermostat are 4.7” W x 4.3” H x 0.9” D. The WIFI reset process allows you to reconnect to a new local WIFI network when needed. To reset the WIFI connection, enter the WIFI menu, hold the + button for three seconds, and you will be returned to the home screen.