LATICRETE Strata Heat WiFi Thermostat Instruction Manual
Troubleshooting
Clock Icon
Time and Date not set
GFCI test button
Connect the STRATA_HEAT™ W-iFi Thermostat to a Wi-Fi
network or alternatively set the time and date from the
settings menu.
GFCI Icon
The GFCI feature is used to detect any leakage of current
from your heating system. During a ground fault the two
lines of the load will be cut off. Once your thermostat is
installed and connected to a power supply you can test the
GFCI function by increasing the set temperature until heating
is on – the heat up icon
GFCI
( ) will be illuminated – and pressing the “TEST” button.
If your test is successful you will see the GFCI error icon and
you will need to hold “X” for 3 seconds in order to restore
heating operation.
Heater error
Relay error
The GFCI has tripped due to a fault in the heater.
(Electrician Required) Electrician required to verify that the
heater has been wired correctly. If correctly wired please
conduct a resistance test and insulation resistance test on the
heater to see if damage has occurred.
Relay icon
The STRATA_HEAT W-iFi Thermostat has detected that one of
the relays has FAILED.
Please contact LATICRETE
16