6. Electrical connection  
Electrical connection includes sensor connection, mains supply and controlled  
pump according to Figure 2. The sensors are Pt1000 type – non-polar.  
If necessary, the connecting cables of the  
sensors can be extended, taking into account the  
total resistance of the two wires - sensitivity of the  
indication 1°С/4Ω. A recommended length that  
does not affect the measurement is up to 100m.  
Terminals 8, 9 are input for the sensor from the  
solar panels.  
Terminals 10, 11 are input for the sensor from the  
boiler.  
A Pt1000 sensor is connected to them.  
Terminals 1, 2 and 3 are supplied with neutral,  
phase and protective earth respectively from the  
mains.  
Fig.2  
The pump is connected to terminals 4, 5 and 6, on which protective earth, neutral  
and phase come out, respectively. A phase (L2) is output on terminal 7, while it is  
not output on terminal 6 (L1).  
Attention: In order to remove the static electricity that accumulates in the solar  
panels, it is mandatory that they as well as their metal structure to be  
grounded. Otherwise, there is a risk of damaging the sensors as well as the  
controller.  