Home > INTIEL Controllers > INTIEL Controllers DT 3.1 Programmable Differential Thermostat User Guide
INTIEL Controllers DT 3.1 Programmable Differential Thermostat User Guide
Table 1
Indication
dt
P A R A M E T E R
Default
settings
User
settings
Description
Range
Set temperature difference
between the solar panels and
the boiler - ∆T
2 ÷ 20 °С
10 °С
Set temperature in the boiler
to which it can normally be
heated by the solar panels.
10 ÷ 80 °С
60 °С
tbS
Tb
set
Minimum temperature in the
boiler below which the
defrosting of the panels
stops. Тbmin
not set
20 °С
Maximum allowable
temperature in the boiler.
Tbmax
80 ÷ 100 °С
20 ÷ 50 °С
80 ÷ 110 °С
95 °С
40 °С
tbH
tPL
tPH
Minimum temperature of
solar panels. Трmin
Maximum allowable
temperature of solar panels.
Трmax
105 °С
Temperature at which solar
panels are allowed to
defrost. Тpdef
-20 ÷ 10 °С
OFF
tPd
Cooling delay time to set
temperature.
0 ÷ 5 h.
4 h.
0 °С
0 °С
ttc
Correction of the indication
temperature Tb
-10 ÷ 10 °С
-10 ÷ 10 °С
Tb correct
Tp correct
Correction of the indication
temperature Tp
11