Hotwire HWTH Horizontal Thermostat Instructions
HotwireThermostat
Technical Information
Configuration Menu
To enter into the setting menu please follow the steps below:
POWER
Step 1. Turn the thermostat off by pressing
MENU
Step 2. Press
you will then see menu 01.
Step 3. Use the up and down arrows to adjust the sensor selection which is Menu 01(Air sensing;Air and Floor, or Floor only)
NEXT
Step 4. Press
Setp 5. Press
to move to the next Menu and once you have all the menu options set,
to accept and store.
DONE
Menu #
Adjustment
(Press up & down buttons to adjust)
Feature
Explanation
This thermostat is a combination model which allows you
to choose 3 different modes.
A / AF / F
01
Mode/Sensor Selection
Switching differential
A mode = Air Sensing Only(Has built in sensor)
AF mode = Air & Floor sensing (Floor probe must be installed)
F mode = Floor Sensing(Floor probe must be installed)
The number of degrees difference before switching.
The default is 1°C which means the thermostat will switch
the heating on 0.5°C below the set temperature and will turn
it off 0.5°C above the set temperature.With a 2°C differential
the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
02
1 Deg C, 2 Deg C....10 Deg C ( 1 Deg C by default)
-1 Deg C = decrease 1 °C , 1 Deg C = increase 1
Deg C
03
04
Air Temp Calibration
This is to recalibrate the air temp if required
-1 Deg C = decrease 1 °C , 1 Deg C = increase 1
Deg C
Floor Temp Calibration
This is to recalibrate the floor temperature if required
A = Show Air Temperature
F = Show Floor Temperature
A-F = Show Floor and Air Temperature in 5 sec
intervals
Temperature Readout
(AF mode only)
This gives you the option to show the Air Temp,
Floor Temp or to show both Air & Floor at intervals
05
Maximum Floor Temp
( AF Mode only)
06
07
This is to protect the floor surface
20 Deg C - 40 Deg C (40 Deg C by default)
Deg C / Deg F
This allows the temperature to be set to show
Deg Celsius or Deg Fahrenheit
Temperature Format
You can select the clock to show in either 12
or 24 hour time
08
09
Clock Format
24 (default), 12- hour or 24-hour clock format
On = activated, Off = deactivated
Frost Protection
This is to avoid your room temp going below 5 DegC
This allows you to programme either 5 days at once,
then the 2 days of the weekend separately,
or a full 7 days at the same time or 7 days separately.
01 = 5 + 2 Day Programming
02 = 7 Day Programming
10
5+2 / 7 Day mode
Auto/Manual mode
selection
00 = Auto mode
01 = Manual mode
11
12
13
This allows you to choose Auto / Manual mode
This is for review only
Software version
V1.0
Minimum temperature
limit
This gives you the option to change the minimum set
temperature
5 °C~ 20 °C (5 °C by default)
Maximum temperature
limit
This gives you the option to change the maximum set
temperature
This gives you the option to change the maximum set
temperature
14
10 = NTC10K(by default), 100= NTC100K,
3=NTC3K
15
16
17
Sensor type selection
Not at use
This allows you to match your thermostat to different sensor
Reserved for future use
Press and hold down button until you see RES on
screen
Reset
This allows you to reset your thermostat to factory default
| General | Details |
|---|---|
| Name | Hotwire HWTH Horizontal Thermostat Instructions |
| Make | Hotwire |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.26 MB |

HWGL2 Hotwire Thermostat Instructions

HWTH Horizontal Hotwire Thermostat Instructions

Hotwire HWGL2 Dual Programming Thermostat Instructions

HotWire R220 WiFi Thermostat Instruction Manual