Installation and Wiring
Change between Manual and Auto Mode
To change between Auto and Manual mode press and hold
The thermostat maintains a constant set temperature manually set by the user.
Simply adjust the temperature using the arrows. In Auto mode, the thermostat
executes the preprogrammed schedules.
Carefully separate the front half of the thermostat from the back plate by
unscrewing the small screw at the bottom of the thermostat. Carefully unplug the
ribbon connector which is plugged into the front half of the thermostat. Place the
thermostat front half somewhere safe. Terminate the thermostat as shown in the
diagrams below.
Lock the Keypad
To lock the keypad, press and hold the power button for 5 seconds, you will
see a key symbol
will disappear.
. To unlock, repeat the steps above and the key symbol
Screw the thermostat back plate onto the flush box
Reset to Factory Setting
Re-connect the thermostat ribbon cable and clip the two halves together.
The conduct a master reset to factory settings, press the power button to turn
the thermostat off. Press and hold
for 5 seconds. Move to menu 16 then
hold the Decrease button for 5 seconds.
7
N
N
L
L
Floor Sensor
60mm
45mm
Connect green
wire from the
element to the
house earth.
LOAD (16A)
Rear View
FEED
(230
VAC)
80mm
This product should be installed by
a qualified electrician.
| General | Details |
|---|---|
| Name | Hotwire HWGL2 Dual Programming Thermostat Instructions |
| Make | Hotwire |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |

HWGL2 Hotwire Thermostat Instructions

HWTH Horizontal Hotwire Thermostat Instructions

Hotwire HWTH Horizontal Thermostat Instructions

HotWire R220 WiFi Thermostat Instruction Manual