Setting the PROGRAMME
Six time and temperature settings are available in each 24 hour period.
Pressing BACK at any time in this process will return you to normal
operating mode.
Press '-' or '+'
to select day to
programme
Press ENTER three
times
The day of the week
will flash
Press '-' or '+' to
select time /
temperature period
you wish to set (P1
to P6)
Press ENTER
Press ENTER
Time / Temperature
setting P1 will flash
Temperature will
flash, use the '-' or
'+' to select the
required
Press ENTER
temperature
Press '-' or '+' to
adjust the hours
then press ENTER.
The minutes will
then flash.
Press '-' or '+' to
adjust the minutes
then press ENTER.
The hours START
time will flash
If you require to set further periods for On completion of period 6
the same day, the next period will now (P6) go to the copy
automatically flash. Follow this process process on Page 11 of
again to programme as required
this booklet
If only two different temperature settings are required in 24 hours then set
the first time and temperature using programme one (P1) and the second
time and temperature setting using programme setting two (P2). The
remaining programmes (P3 to P6) should all be set to the same time and
temperature as P2.
This same method can be used if three, four or five temperature levels are
required, always using the first settings to provide the temperature change
commands with the remaining settings that are not required set to the same
time and temperature as the last required setting.