RLV450  
PROGRAMMABLE THERMOSTAT  
USER GUIDE  
READ BEFORE INSTALLING  
DESCRIPTION  
INSTALLATION  
Temperature pre-  
set buttons  
WARNING  
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN  
POWER PANEL TO AVOID ELECTRICAL SHOCK. THE  
INSTALLATION MUST BE PERFORMED BY AN ELECTRICIAN.  
All cables and connections must conform to the local electrical  
code.  
Indicates that the tem-  
perature setpoint is dis-  
played  
Indicates that the set-  
tings are locked  
Time and day  
Special CO/ALR solderless connectors must be used when  
connecting with aluminum conductors.  
Install the thermostat onto an electrical box.  
Install the thermostat about 5 feet high, on an inside wall facing the  
heater.  
Avoid locations where there are air drafts (such as the top of a  
staircase or an air outlet), dead air spots (such as behind a door),  
or direct sunlight.  
Do not install the thermostat on a wall that conceals chimney or  
stove pipes.  
Set the hour  
Set the minute  
Temperature  
Indicates the current  
mode of operation  
Set the day  
Program the schedule  
Temperature pre-  
set icon  
Skip a period  
Indicates that the  
thermostat is configured  
for a fan-forced heater  
Select the mode of  
operation  
Indicates the  
heating power  
The thermostat wires are not polarized; either wire can be  
connected to the load or to the power supply.  
Indicates the current  
period (appears in auto-  
matic mode only)  
Temperature  
adjustment but-  
tons  
NOTE:  
Always keep the thermostat's vents clean and unobstructed.  
Indicates that the thermostat  
is without power *  
1.  
* LP appears only for the first two minutes when the thermostat is without  
power. This can occur during a power outage or when the thermal protection  
device inside the baseboard heater is opened.  
Fig. 1.  
This programmable thermostat can be used to control an electric heating  
system such as an electric baseboard heater, a radiant ceiling, a radiant floor,  
a convector or a fan-forced heater.  
The thermostat cannot be used with:  
a resistive load over 16.7 A  
a resistive load under 2 A  
a system driven by a contactor or relay (inductive load)  
a central heating system  
M38000  
SUPPLIED PARTS:  
One (1) thermostat  
Two (2) 6-32 screws  
Two (2) solderless connectors  
Fig. 2.  
69-2201ES-08  
GeneralDetails
NameHoneywell RLV450 Programmable Thermostat User Guide
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size0.56 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell RLV450 Programmable Thermostat User Guide
Get the free PDF manual for the Honeywell RLV450 Programmable Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Honeywell RLV450 Programmable Thermostat User Guide Overview

Summary of Contents

  • Page 1: RLV450 programmable thermostat user guide Read before installing Installation must be performed by an electrician. Turn off power to the heating system at the main power panel to avoid electrical shock. All cables and connections must conform to the local electrical code. Install the thermostat about 5 feet high, on an inside wall facing the heater. Avoid locations with air drafts, dead air spots, or direct sunlight. The thermostat can control an electric heating system such as an electric baseboard heater or a fan-forced heater. The thermostat cannot be used with a resistive load over 16.7 A or under 2 A. Special CO/ALR solderless connectors must be used when connecting with aluminum conductors. Always keep the thermostat's vents clean and unobstructed.
  • Page 2: Connect the thermostat wires to the line wires and to the load wires using solderless connectors for copper wires. Early Start can be used in Automatic mode only. When this function is enabled, the thermostat calculates the optimal time to start heating to obtain the desired temperature by the set time. Select 15-second cycles in most cases as it provides better temperature control. However, you must select 15-minute cycles if you have a fan-forced heater. The settings are locked. The temperature adjustment buttons only allow you to view the temperature setpoint. The thermostat can automatically re-adjust its clock at Daylight Savings Time changeover. The function is disabled (default setting) when the clock loses its setting. The configuration switches are on the back of the thermostat. The factory settings are indicated by the gray cells in the following table. The thermostat normally displays the actual temperature. To view the setpoint, press the V or W button briefly. To change the setpoint, press the V or W button until the desired temperature is displayed.
  • Page 3: The thermostat has 3 preset temperatures: Comfort, Economy, and Vacation. Comfort temperature is used during periods 1 and 3, while Economy temperature is used during periods 2 and 4. You can have a different program for each day of the week. To use the Comfort or Economy temperature, press the corresponding button. To store the Comfort or Economy temperature, press and hold the appropriate button for approximately 3 seconds. To modify the schedule, access the programming mode and select the day to program. Automatic mode sets the temperature according to the programmed schedule. Temporary Bypass allows modification of the setpoint until the end of the current period. During a power outage, settings are stored in memory, but the thermostat’s clock must be re-adjusted if the outage exceeds 4 hours. Manual mode requires the temperature to be set manually, without using the programmed schedule.
  • Page 4: Solutions The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health. Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one year from the date of first purchase by the original purchaser. If the product is defective, return it with a bill of sale or other dated proof of purchase. This warranty does not cover removal or reinstallation costs. Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions about the operation of your thermostat, please contact customer assistance. Approval: CSA / UL
  • Page 5: RLV450 Termostato programable Guía del usuario Leer antes de instalar Descripción Instalación Advertencia Cortar la alimentación del sistema de calefacción en el panel de alimentación principal para evitar riesgos de electrocución. La instalación debe hacerla un electricista. El termostato debe instalarse a alrededor de 1,5 m (5 pies) del piso, en una pared interior frente al aparato de calefacción. No debe instalarse el termostato en una pared que oculte conductos de chimeneas o estufas. Este termostato programable puede usarse para controlar un sistema de calefacción eléctrico, tal como una estufa eléctrica de zócalo, un cielorraso radiante, un piso calefaccionado, un convector eléctrico o un calefactor a aire forzado.
  • Page 6: Conectar los cables del termostato a la alimentación y a la carga por medio de conectores sin soldadura para cables de cobre. El encendido anticipado puede usarse en modo automático solamente. Cuando esta función está activada, el termostato calcula el momento óptimo de encendido de la calefacción para obtener la temperatura deseada a la hora establecida. En la mayoría de los casos se deben seleccionar ciclos de 15 segundos, porque permiten un mejor control de la temperatura. Los ajustes están bloqueados. Los botones de ajuste de la temperatura sólo permiten ver el punto de ajuste de la temperatura. El termostato puede reajustar la hora automáticamente cuando hay que hacer el cambio a la hora de verano. Esta función está desactivada por defecto cuando se pierde el ajuste de la hora. Los conmutadores de configuración están en la parte posterior del termostato. El termostato indica normalmente la temperatura del momento. Para cambiar el punto de ajuste, presionar los botones V o W hasta que aparezca la temperatura deseada.
  • Page 7: Uso de la temperatura predefinida. La temperatura de Confort se usa en los períodos 1 y 3 y la temperatura de Economía en los períodos 2 y 4. El termostato tiene 3 temperaturas predefinidas: Temperatura de Confort, Temperatura de Economía, Temperatura de Vacaciones. Se puede tener un programa diferente para cada día de la semana. Para usar la temperatura Confort o Economía, presionar el botón correspondiente. Para modificar el horario, presionar Pgm para acceder al modo de programación. En caso de corte de corriente, los ajustes están salvaguardados en la memoria. El horario consiste en 4 períodos por día, que representan un día de semana típico. El termostato puede estar en modo automático, cancelación temporaria o manual. La temperatura medida puede aparecer como LO o HI si está fuera del margen de visualización del termostato.
  • Page 8: Instromet Mexicana S. de R.L. de C.V. garantiza que este producto está libre de defectos en su mano de obra y materiales contra cualquier defecto de fabricación y funcionamiento, bajo uso normal, por el término de 1 año a partir de la fecha de la compra por el consumidor. Si se determina que el producto está defectuoso, Instromet deberá reparar o reemplazar el producto bajo ciertas condiciones. La pantalla aparece pálida cuando la calefacción está activada. El rendimiento del termostato es reducido debido a un error del sensor. Esta garantía no cubre gastos de mano de obra por re-instalación. La única responsabilidad de Instromet será reparar o reemplazar el producto dentro de los términos establecidos. Esta garantía es la única garantía expresa que Instromet ofrece respecto de este producto. La duración de cualquier garantía implícita se limita a la duración de un año de esta garantía. El producto no es válido si ha sido utilizado en condiciones distintas a las normales. Este aparato digital de clase B cumple con la normativa canadiense ICES-003.