Honeywell RLV450 Programmable Thermostat User Guide
RLV450
PROGRAMMABLE THERMOSTAT
USER GUIDE
READ BEFORE INSTALLING
DESCRIPTION
INSTALLATION
Temperature pre-
set buttons
WARNING
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK. THE
INSTALLATION MUST BE PERFORMED BY AN ELECTRICIAN.
All cables and connections must conform to the local electrical
code.
Indicates that the tem-
perature setpoint is dis-
played
Indicates that the set-
tings are locked
Time and day
Special CO/ALR solderless connectors must be used when
connecting with aluminum conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing the
heater.
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a door),
or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
Set the hour
Set the minute
Temperature
Indicates the current
mode of operation
Set the day
Program the schedule
Temperature pre-
set icon
Skip a period
Indicates that the
thermostat is configured
for a fan-forced heater
Select the mode of
operation
Indicates the
heating power
The thermostat wires are not polarized; either wire can be
connected to the load or to the power supply.
Indicates the current
period (appears in auto-
matic mode only)
Temperature
adjustment but-
tons
NOTE:
Always keep the thermostat's vents clean and unobstructed.
Indicates that the thermostat
is without power *
1.
* LP appears only for the first two minutes when the thermostat is without
power. This can occur during a power outage or when the thermal protection
device inside the baseboard heater is opened.
Fig. 1.
This programmable thermostat can be used to control an electric heating
system such as an electric baseboard heater, a radiant ceiling, a radiant floor,
a convector or a fan-forced heater.
The thermostat cannot be used with:
•
•
•
•
a resistive load over 16.7 A
a resistive load under 2 A
a system driven by a contactor or relay (inductive load)
a central heating system
M38000
SUPPLIED PARTS:
•
•
•
One (1) thermostat
Two (2) 6-32 screws
Two (2) solderless connectors
Fig. 2.
69-2201ES-08
| General | Details |
|---|---|
| Name | Honeywell RLV450 Programmable Thermostat User Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.56 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell RLV450 Manual: Questions and Answers
What's the difference between 15-second and 15-minute cycle settings on the Honeywell RLV450?
15-second cycles provide better temperature control. Select 15-minute cycles only if you have a fan-forced heater. User Guide, p. 2
What does the LP indicator on the Honeywell RLV450 display mean?
LP signals the thermostat has no power. It appears for two minutes during a power outage or when the heater's thermal protection opens. User Guide, p. 1
What does it mean when the FAN word appears on the Honeywell RLV450 display?
FAN indicates that 15-minute cycle mode is selected, which is required for fan-forced heaters. User Guide, p. 2