Home > Honeywell > Honeywell RLV450 Programmable Thermostat User Guide

Honeywell RLV450 Programmable Thermostat User Guide

RLV450  
Using a preset temperature  
Table 3.  
Description  
Period  
Setting  
The thermostat has 3 preset temperatures:  
Comfort temperature  
Economy temperature  
Vacation temperature  
Wake  
Leave  
Return  
Sleep  
Table 2.  
Intended use  
Comfort (when at home)  
Icon  
Factory setting  
70°F (21°C)  
The Comfort ( ) temperature is used in periods 1 and 3 and the Economy  
( ) temperature is used in periods 2 and 4. For example, when the period  
changes from 1 to 2, the setpoint automatically changes from Comfort  
setting ( ) to Economy setting ( ).  
Economy (when asleep or away from  
home)  
62°F (16.5°C)  
Vacation (during prolonged absence) 50°F (10°C)  
You can have a different program for each day of the week; i.e., each period  
can start at different time for each day of the week. The thermostat has been  
programmed with the following schedule.  
To use the Comfort or Economy temperature, press the or button  
respectively. The corresponding icon will be displayed.  
To use the Vacation temperature, press both and buttons  
simultaneously. The icon will be displayed.  
Table 4.  
Period Setting MO  
TU  
WE  
TH  
FR  
SA  
SU  
6:00  
AM  
6:00  
AM  
6:00  
AM  
6:00  
AM  
6:00  
AM  
6:00  
AM  
6:00  
AM  
Storing a preset temperature  
To store the Comfort or Economy temperature:  
Set the desired temperature using the V or W button. Press and hold the  
appropriate button ( or ) for approximately 3 seconds until the  
corresponding icon is displayed.  
8:00  
AM  
8:00  
AM  
8:00  
AM  
8:00  
AM  
8:00  
AM  
--:--  
--:--  
--:--  
--:--  
6:00  
PM  
6:00  
PM  
6:00  
PM  
6:00  
PM  
6:00  
PM  
10:00 10:00 10:00 10:00 10:00 10:00 10:00  
PM PM PM PM PM PM PM  
To store the Vacation temperature:  
Set the desired temperature using the V or W button. Press and hold both  
and buttons simultaneously for approximately 3 seconds until the  
icon is displayed.  
To modify the schedule:  
1. Press Pgm to access the programming mode. Period 1 is selected.  
2. Press Day to select the day to program (hold for 3 seconds to select  
the entire week).  
3. Press Hour and Min to set the start time of the selected period, or  
press Clear if you want to skip the period (--:-- is displayed).  
4. Press Pgm to select another period, or press Day to select another  
day. Then repeat step 3.  
MODES OF OPERATION  
Automatic - The temperature is set according to the programmed  
schedule. To place the thermostat in this mode, press the Mode button  
until is displayed. The icons of the current period and preset temperature  
are also displayed.  
5. Press Mode to exit the programming mode.  
NOTE:  
If no button is pressed for 60 seconds, the thermostat will auto-  
matically exit the programming mode.  
Temporary Bypass - If you modify the setpoint (by pressing the V, W,  
or button) when the thermostat is in automatic mode, the new setpoint  
will be used until the end of the current period. When the next period starts,  
the temperature set for that period becomes the new setpoint. To cancel the  
bypass, press the Mode button.  
POWER OUTAGE  
During a power outage, LP (Low Power) appears for the first minute. Then  
the screen becomes blank. The settings are stored in memory. After initial  
installation, product must be connected to power for a minimum of two hours  
to enable the power outage feature. However, if the power failure exceeds 4  
hours, only the thermostat’s clock must be re-adjusted. When power returns,  
the thermostat will return to the mode of operation active prior to the power  
failure.  
Manual - The programmed schedule is not used. The temperature must  
be set manually. To place the thermostat in this mode:  
1. Press the Mode button until is displayed.  
2. Set the temperature using the V, W,  
or button.  
SCHEDULE  
TROUBLESHOOTING  
The schedule consists of 4 periods per day which represents a typical  
weekday. You can program the thermostat to skip the periods that do not  
apply to your situation. For example, you can skip periods 2 and 3 for the  
weekend.  
Table 5.  
Problem  
Solutions  
Thermostat is hot.  
Under normal operation, the thermostat housing  
can reach a temperature between 95°F (35°C)  
and 104°F (40°C).  
LO is displayed.  
The measured temperature is below the display  
range. Heating is activated.  
3
69-2201ES—08  
GeneralDetails
NameHoneywell RLV450 Programmable Thermostat User Guide
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size0.56 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell Lyric T5 Wi-Fi Thermostat Installation Guide
Honeywell Lyric T5 Wi-Fi Thermostat Installation Guide

Honeywell RLV450 Programmable Thermostat User Guide