Custom Alerts 1 through 4  
Allows the dealer to enter a custom alert to be displayed when a dry contact device is activated. For example, a float switch can  
detect when your sump pump is not working.  
When Custom Alert 1 through Custom Alert 4 is selected in ISU 6005, the T10+ asks you to name the alert and then gives options  
for additional settings related to the alert. These settings are:  
Which set of S terminals on the EIM the dry contact alert  
is wired to (ISU 6190).  
Activate Fan (ISUs 6230, 6340, 6440, 6540)  
If selected, this setting turns on the fan when the selected  
custom dry contact alert (custom dry contact 1 through 4)  
is active.  
There are four (4) sets of configurable S terminals on the  
EIM. If a set of S terminals is already configured for use  
by a different dry contact alert (or sensor), it will not be  
configurable.  
Activate Custom U terminal (ISUs 6230, 6340, 6440,  
6540)  
Whether the switch wired to these terminals is normally  
open or closed (ISU 6200).  
If you choose to activate a custom U terminal during a  
custom alert, the T10+ will ask you to name the U terminals  
used. That way the T10+ equipment status menu can  
show what is being turned on or locked out. For example,  
you could wire a shut off valve to the U contacts and the  
status would then show “Shut off valve energized” under  
equipment status  
The switch wired to the S terminals could either be open in  
normal (not alert) conditions or closed.  
Enter the dry contact alert name (ISU 6210).  
Whether there is an alert message displayed when the  
alert is active (ISU 6215).  
Humidifier Lockout (ISU 8095)  
In most cases, the installer would want an alert message to  
appear on the T10+ if there was a dry contact alert active.  
However, the installer may be using the “alert” to do some  
other action (like running a ventilator when a sensor is  
reading high CO2). This may be normal operation and they  
may not wish to show an alert.  
If the T10+ and EIM are set for a custom dry contact alert  
and to control a humidifier, you can choose to lock out the  
humidifier during a custom dry contact alert (the water leak  
alert option also offers this setting)  
Dehumidifier Lockout (ISU 9145)  
Lock Out Heat or Lock Out Cool (ISUs 6230, 6340, 6440,  
6540)  
If the T10+ and EIM are set for a custom dry contact alert  
and to control a dehumidifier, you can choose to lock out  
the dehumidifier during a custom dry contact alert.  
If the installer previously chose to lock out heat or cool on a  
custom dry contact alert condition, The T10+ will then ask if:  
Turn On Ventilator (ISU 10065)  
»
You want a delay before the lockout (ISU 6600 or 6620).  
For example, if someone was using a door sensor to lock  
out cooling, you wouldn’t want to short cycle the cooling  
every time someone enters or exits. But if the door is left  
open for a certain length of time, you may wish to shut  
down the heat or cooling.  
If the T10+ and EIM are set for a custom dry contact alert  
and to control a ventilator, you can choose to turn on the  
ventilator during a custom dry contact alert.  
Lockout Ventilator (ISU 10140)  
If the T10+ and EIM are set for a custom dry contact alert  
and to control a ventilator, you can choose to lock out the  
ventilator during a custom dry contact alert  
»
If you still want a maximum temperature for cool  
(ISU 6610) or minimum indoor temperature for heat  
(ISU 6630). Example: If someone had a heat lockout  
configured when the window was open, they left the  
window open, and the indoor temperature dropped to  
40°F, you probably still want the heat to run because the  
danger of pipes freezing overrides the inefficient use of  
heating with a window open  
2
Installer Setup (ISU)  
NOTES:  
For this file, only the dry contact ISU settings are shown. Full ISU settings are found in the product  
00000s/33-00462.pdf.  
The firmware is occasionally updated over the air (OTA) from the factory. To ensure the latest firmware  
updates are installed, confirm the thermostat is connected to a stable WiFi connection. Some ISU  
settings may not be shown on models that don’t have the latest firmware.  
Contingent EIM  
Previous Setting? Needed?  
T10, T10+,  
or Both  
ISU #  
Heading  
Question  
Options  
Notes  
6000  
Dry Contact Alerts  
Select dry contact alerts  
Full Drain Pan Alert, Dirty  
Filter Alert, Water Leak Alert,  
System Shutdown Alert,  
Service Needed Alert, Fan  
Failure Alert.  
Yes  
T10+  
See dry contact alert  
for operation details  
6005  
6050  
Dry Contact Alerts  
Dry Contacts  
Select dry contact alerts  
Custom Alert 1, Custom Alert  
2, Custom Alert 3, Custom  
Alert 4  
Yes  
T10+  
T10+  
See dry contact alert  
for operation details  
What terminals are wired  
to the full drain pan alert  
dry contact?  
None, EIM S1, EIM S2, EIM  
S3, EIM S4  
6000 has full drain Yes  
pan selected  
See dry contact alert  
for operation details  
6060  
6065  
6070  
Dry Contacts  
Dry Contacts  
Dry Contacts  
Full drain pan alert dry  
contact setup  
Normally Open, Normally  
Closed  
Yes  
Yes  
T10+  
T10+  
T10+  
Full drain pan alert dry  
contact actions  
System shutdown (select or  
de-select)  
What terminals are wired  
to the Dirty filter alert dry  
contact?  
None, EIM S1, EIM S2, EIM  
S3, EIM S4  
6000 has dirty air  
filter selected  
Yes  
See dry contact alert  
for operation details  
6080  
6090  
Dry Contacts  
Dry Contacts  
Dirty filter alert dry  
contact setup  
Normally Open, Normally  
Closed  
Yes  
Yes  
T10+  
T10+  
What terminals are wired  
to the water leak alert dry  
contacts?  
None, EIM S1, EIM S2, EIM  
S3, EIM S4  
6000 has water  
leak selected  
See dry contact alert  
for operation details  
6100  
6110  
Dry Contacts  
Dry Contacts  
Water leak alert dry  
contact setup  
Normally Open, Normally  
Closed  
Yes  
Yes  
T10+  
T10+  
What terminals are wired  
to the system shutdown  
alert dry contact?  
None, EIM S1, EIM S2, EIM  
S3, EIM S4  
6000 has system  
shutdown alert  
selected  
See dry contact alert  
for operation details  
6120  
6130  
Dry Contacts  
Dry Contacts  
System shutdown alert  
dry contact setup  
Normally Open, Normally  
Closed  
Yes  
Yes  
T10+  
T10+  
What terminals are wired  
None, EIM S1, EIM S2, EIM  
6000 has service  
needed alert  
selected  
See dry contact alert  
for operation details  
to the service needed alert S3, EIM S4  
dry contact?  
6140  
6150  
Dry Contacts  
Dry Contacts  
Service needed alert dry  
contact setup  
Normally Open, Normally  
Closed  
Yes  
Yes  
T10+  
T10+  
What terminals are wired  
to the fan failure alert dry  
contact?  
None, EIM S1, EIM S2, EIM  
S3, EIM S4  
6000 has fan  
failure alert  
selected  
See dry contact alert  
for operation details  
6160  
6190  
Dry Contacts  
Dry Contacts  
Fan failure alert dry  
contact setup  
Normally Open, Normally  
Closed  
Yes  
Yes  
T10+  
T10+  
What terminals are wired  
to the custom alert 1 dry  
contact?  
None, EIM S1, EIM S2, EIM  
S3, EIM S4  
6005 has custom  
alert 1 selected  
See dry contact alert  
for operation details  
6200  
Dry Contacts  
Custom alert 1 dry  
contact setup  
Normally Open, Normally  
Closed  
Yes  
T10+  
6210  
6215  
Dry Contacts  
Dry Contacts  
Custom alert 1 name  
Type in the alert name  
Yes, No  
Yes  
Yes  
T10+  
T10+  
Show custom alert 1  
message  
Will an alert message  
be shown on display  
when alert 1 is active?  
6220  
6230  
Dry Contacts  
Dry Contacts  
Custom alert 1 message  
Custom alert 1 actions  
Type in the message  
displayed when this alert is  
active  
6215 is set to Yes  
Yes  
Yes  
T10+  
T10+  
See dry contact alert  
for operation details  
Lockout Heat, Lockout  
Cool, Activate Fan, Activate  
Custom U Terminal  
6005 has custom  
alert 1 selected  
3
GeneralDetails
NameHoneywell Home T10 Smart Home Thermostat Instructions
MakeHoneywell Home
LanguageEnglish
FiletypePDF (Download)
File size0.14 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell Home TH8320R1003-Uv VisionPRO 8000 with RedLINK Multistage Thermostat Installation Guide
Honeywell Home TH8320R1003-Uv VisionPRO 8000 with RedLINK Multistage Thermostat Installation Guide
Honeywell Home TH2110DH 1 Cool Programmable Digital Thermostat Installation Guide
Honeywell Home TH2110DH 1 Cool Programmable Digital Thermostat Installation Guide
Honeywell Home DT4R Wireless Room Thermostat User Guide
Honeywell Home DT4R Wireless Room Thermostat User Guide
Honeywell Home N100 Series Non Programmable Thermostat User Guide
Honeywell Home N100 Series Non Programmable Thermostat User Guide
Honeywell Home X1N Non Programmable Thermostat Installation Guide
Honeywell Home X1N Non Programmable Thermostat Installation Guide
Honeywell Home DT4M Wired Room Thermostat User Manual
Honeywell Home DT4M Wired Room Thermostat User Manual
Honeywell Home T834 Series Thermostat Owner’s Manual
Honeywell Home T834 Series Thermostat Owner’s Manual
Honeywell Home M38794 T10 and T10 plus Pro Smart Thermostat with RedLINK Installation Guide
Honeywell Home M38794 T10 and T10 plus Pro Smart Thermostat with RedLINK Installation Guide
Honeywell Home DT4 Channel Wired Room Thermostat Instruction Manual
Honeywell Home DT4 Channel Wired Room Thermostat Instruction Manual
Honeywell Home FocusPRO Smart S200 Series Smart Thermostat User Guide
Honeywell Home FocusPRO Smart S200 Series Smart Thermostat User Guide

Honeywell Home T10 Smart Home Thermostat Instructions