Danfoss RET1001M – V2 Room Thermostat Installation Guide
| General | Details |
|---|---|
| Name | Danfoss RET1001M – V2 Room Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.81 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss RET1001M V2 Manual: Questions and Answers
Danfoss RET1001M V2 specifications
| Power supply | 230Vac 10% 50/60Hz |
| Setpoint range | 5 °C to 30 °C |
| IP rating | IP30 (installed) |
| Wire size | max 2.5 mm2 wires |
What is the setting temperature range for Danfoss RET1001M V2?
5 °C to 30 °C. Installation Guide, p. 7
What do the L, COM, NC, and NO terminals on Danfoss RET1001M do?
| Terminal | Function |
|---|---|
| L | Live 230 V ~ (both internally linked) |
| COM | Common |
| NC - OFF | Normally closed, switches off |
| NO - ON | Normally open, switches on |
Can I use Danfoss RET1001M to replace a 230-volt room thermostat?
Yes. You must link the live (L) terminal to a common (COM) terminal. Installation Guide, p. 45
How do I remove the back plate from Danfoss RET1001M V2?
Loosen the lower retaining screws and carefully remove the back plate. Installation Guide, p. 4
What do the green and red LED indicators mean on Danfoss RET1001M?
| LED Indicator | Meaning |
|---|---|
| Green | Power on |
| Red | Thermostat Output on |
Danfoss RET1001M V2 compared with other room thermostats
| Specification | Danfoss RET1001M V2 | BECA BHP-8000 C | BEOK BOT-R6W | BEOK TCR7 |
|---|---|---|---|---|
| Power supply | 230Vac 10% 50/60Hz | 24VDC/AC +10% | 3 x 1.5 V alkaline AA battery | AC100~240V50/60Hz |
| Setpoint range | 5 °C to 30 °C | 42-122 ℉ (5~50℃) | 5-60℃(Default) | 5~95℃ / 41~203℉ |
| IP rating | IP30 (installed) | IP20 | IP20 | IP20 |