HIVE 81351 Thermostat Mini for Heating Installation Guide
Hive Thermostat Mini Installation Guide
3c
Dual channel Receiver
wiring:
S-Plan wiring: (typically has two,
two-port valves)
Dual channel Receivers do not have a switch,
so you do not need to worry about operating
modes.
If there is an existing room thermostat, this may
need to be bypassed or linked out. If you need to
link it out, this can either been done in the wiring
centre or at the thermostat, but best practice
would always be at the wiring centre. A direct
feed from the central heating on terminal needs
to communicate with the brown of the two-port
valve.
N: Permanent neutral
L: Permanent live
1: Hot water off
2: Heating off
3: Hot water on
4: Heating on
Y-Plan wiring: (typically has a
single three-port valve)
If there is an existing room thermostat, this may
need to be bypassed or linked out. If you need to
link it out, this can either been done in the wiring
centre or at the thermostat, but best practice
would always be at the wiring centre. A direct
feed from the central heating on terminal needs
to communicate with the white of the three-port
valve.
Earth
tether
NOTE: Remove any existing controls or
programmers and ensure pre-existing wires
or connections are made safe.
10
| General | Details |
|---|---|
| Name | HIVE 81351 Thermostat Mini for Heating Installation Guide |
| Make | HIVE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.35 MB |

HIVE HAH2INSTAMZ-01 Active Heating Thermostat User Guide

HIVE SLT3 Thermostat User Guide

HIVE 852031 Mini Wireless Heating Smart Thermostat Instructions

HIVE Thermostat for Heating Owner’s Manual

HIVE Thermostat Mini User Guide

HIVE Cheap Smart Thermostat User Guide

Hive B011B3J6B8 Active Heating Thermostat Owner’s Manual