5. INSTALLATION  
Note! The top cover has to be installed when the thermostat  
is connected to the main power source. The thermostat is not  
a SELV product. All voltage parts must be considered to be  
230VAC.  
Installation must be done by a qualified electrician in accordance with  
the National Building codes. Before installation, disconnect the power  
to the device from the mains. During installation of the device, power  
to the device must be disconnected AT ALL TIMES!  
6. ADD/REMOVE  
51.1mm  
15.6mm  
Please read this before installation  
49.5mm  
21.3mm  
The primary controller/gateway has a mode for adding or removing  
devices. Please refer to your primary controller manual on how to set  
the primary controller in add/remove mode. The device may only be  
added or removed from the network if the primary controller is in add/  
remove mode. When the device is removed from the network, it will  
NOT revert to factory settings.  
There are two ways to add the device to a Z-Wave network.  
6.1 Method 1: Standard (Manual)  
1. Press Center (confirm) for 10 seconds. The display will show OFF.  
2. Press Right (down) 5 times until you see Con on the display.  
3. Start the add/remove device process in your primary controller.  
4. Start the add/remove mode by pressing Center (confirm) for  
approximately 2 seconds.  
5.1 Controls  
Use e.g. a small slotted screwdriver. Start by carefully removing the  
front cover by pushing the release springs. The front cover and the  
frame may now be removed.  
Adding/removing mode is indicated on the display by rotating  
LED segments on the display. This lasts until the timeout occurs  
after 90 seconds, or until the module has been added/removed in  
the network. Confirmation will show Inc/EcL on the display. Exit  
programming mode by choosing ESC in the menu. Your thermostat  
is now ready for use with default settings.  
58.8mm  
Release spring  
NB! When the thermostat is removed from the gateway, the  
parameters are not reset. To reset the parameters, see Chapter 7:  
”Factory reset. If adding/removing fails, Err (error) will appear.  
Please perform a ”remove deviceprocess and try again. If Err displays  
again, please see Chapter 7: “Factory reset.  
6.2 Method 2: SmartStart (Automatic)  
SmartStart enabled products may be added to a Z-Wave network  
by scanning the Z-Wave QR-Code on the product if your primary  
controller supports SmartStart inclusion. No further action is required  
and the SmartStart product will be added automatically after being  
powered on within range of the primary controller.  
1: Left  
2: Center  
87mm  
3: Right  
Connect the wires to the thermostat terminals:  
Use 1.5mm² or 2.5mm² according to load.  
The Z-Wave QR-Code locations may be found in Chapter 20  
”Z-Wave QR-Code/DSK.  
HEATING (N)  
Heating cable connection (Neutral)  
N
Power connection (Neutral) 230VAC  
Power connection (Live) 230VAC  
Heating cable connection  
7. FACTORY RESET  
L
By pressing buttons Right and Center (down and confirm) for 20 seconds, the  
thermostat will perform a complete factory reset. The device will display rES for  
10 seconds while performing a factory reset. When rES no longer is displayed,  
the thermostat has been reset.  
HEATING (L)  
FLOOR SENSOR  
NTC type (10, 12, 15, 22, 33 or 47kΩ)  
Default 10kΩ  
EXTERNAL SENSOR NTC type (10, 12, 15, 22, 33 or 47kΩ)  
Default 10kΩ  
NB! Please use this procedure only when the primary controller/  
gateway is missing or otherwise inoperable.  
Next, position the thermostat and mount it into the wall flush box  
using 2-4 screws. Position the frame over the flush box, then position  
and carefully press the front cover until it snaps in place. Check that  
the front cover has snapped in place properly on both sides. The front  
cover should now fit firmly on all sides. In order to read the Power  
Metering, the load needs to be connected to both heating L + N.  
7.1 Startup  
After powering up the device for the first time, all the parameters will have  
default settings.  
GeneralDetails
Nameheatit Z-TRM3 WiFi Thermostat Instruction Manual
MakeHEATIT
LanguageEnglish
FiletypePDF (Download)
File size0.19 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
HEATIT Z-TRM3 Thermostat User Guide
HEATIT Z-TRM3 Thermostat User Guide
Heatit Z-TEMP2 Thermostat Installation Guide
Heatit Z-TEMP2 Thermostat Installation Guide
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
4512673 Heatit ZM Thermostat 16A User Guide
4512673 Heatit ZM Thermostat 16A User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT Z-TEMP3 Thermostat User Guide
HEATIT Z-TEMP3 Thermostat User Guide
heatit ET-7AW Touchscreen Programmable Thermostat User Manual
heatit ET-7AW Touchscreen Programmable Thermostat User Manual

heatit Z-TRM3 WiFi Thermostat Instruction Manual