Haswill Electronics STC-8080H Thermostat User Guide
STC-8080H Thermostat
Quick Start Guide
(Version 22.11.03GEN) Video on YouTube
STC-8080H defrosting thermostat with one sensor and
two output relays to connect and control the
refrigeration and the defrosting unit. There is an editable
delay time for the over-temp alarm function.
1. Wiring Diagram
This unit does not output AC electricity; hence you have
to wire all live and null wires to each port; you may use
the jumper wire conveniently.
1 / 4
| General | Details |
|---|---|
| Name | Haswill Electronics STC-8080H Thermostat User Guide |
| Make | HASWILL ELECTRONICS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.11 MB |

Haswill Electronics STC-9100 Thermostat User Manual

Haswill Electronics RC-113M PID Thermostat User Guide

Haswill Electronics STC-8080A+ Thermostat User Guide

Haswill Electronics AL8010H Thermostat User Guide

HASWILL ELECTRONICS STC-200 Thermostat User Guide

Haswill Electronics STC-9200 Thermostat User Guide

Haswill Electronics STC-8080H Thermostat User Guide Overview
Summary of Contents
- Page 1: STC-8080H thermostat quick start guide. Defrosting thermostat with one sensor and two output relays. Editable delay time for the over-temp alarm function. Wiring diagram included. Unit does not output AC electricity. Wire all live and null wires to each port. Use jumper wire conveniently.
- Page 2: Function menu includes various codes for temperature settings and alarm configurations. Temperature for refrigeration starts is indicated by F1, while F2 marks the temperature for refrigeration stops. Temperature calibration and compressor delay time are also part of the function settings. An over-temperature alarm is triggered when the temperature exceeds F1. Alarm delay time is set with F6, and defrosting cycle or interval time is managed with F7. Defrosting lasting time is controlled by F8. The aimed temperature range must be defined between F1 and F2. Refrigeration starts when the temperature is greater than or equal to F1. Refrigeration ends when the temperature is less than or equal to F2. To configure, hold the key for 3 seconds to access the code F1.
- Page 3: Press the key to check the existing value. Hold the key meanwhile press the or key to change the value. Release all keys once it reaches your aim value. Repeat operation from Step 2 / 3 / 4 to adjust other parameters. After configuring all values, press the key to save data and back to normal monitor status. The modified value will be saved automatically and back to normal status if without operation in 30 seconds. Hold the key for 3s to start the forced-defrosting mode. Do it again to stop defrosting. This unit controls the defrosting only by the time, but not by the evaporator temperature like STC-9100.
- Page 4: This is not a step-by-step user manual. It just shows the key points. The new user should read the full-content version user manual. Copyright Haswill-Haswell All rights reserved.