P1 programmable mode is DIY setting  
Long press rotary button for 3s,rotate button to choose , and press button to enter setting interface.then you can orderly  
week,temperature and time. By rotate button to adjust range and press button to confirm and enter next setting  
Time and temperature can’t be adjusted for P2 ,P3 programmable mode.  
P1 manual programmable(default)  
week  
period  
Default period  
Default temperature  
1
0:00-6:00  
15℃  
2
3
6:00-9:00  
21℃  
15℃  
21℃  
15  
21℃  
9:00—12:00  
7 days per days  
4
12:00—14:00  
14:00—17:30  
17:30—23:59  
5
6
P2 setting ,default is 7 days programmable  
week  
period  
Default period  
Default temperature  
1
2
6:00-22:00  
21℃  
7 days per week  
22:00-6:00  
17℃  
P3 setting ,default is 5+2 days programmable  
week  
period  
Default period  
22:006:00  
6:008:00  
Default temperature  
1
2
3
4
1
2
17℃  
21℃  
17℃  
21℃  
21℃  
17℃  
Working days  
80016:00  
16:0022:00  
6:00-22:00  
weekend  
22:00-6:00  
Holiday mode  
Long press rotary button for 3s,rotate button to choose  
,press button to enter into holiday mode.then you orderly set days and  
temperature.Rotate button to adjust range,and press button to confirm.when finish,press button to exit.Set temperature range is  
5~15(default temperature is 10)for holiday mode.In the interface of holiday mode ,it can be canceled by press  
Evening-saving mode  
Long press rotary button for 3s,rotate button to choose ,press button to enter into evening-saving mode,rotate button to set the  
temperature(default temperature 17),press rotary button to confirm and return to last interface,it will skip to next setting icon  
automatically.  
Comfortable mode  
Rotate button to choose ,press button to enter into comfortable mode.then you can set the temperature(default temperature  
17),press rotary button to confirm and return to last interface,it will skip to next setting icon  
automatically.  
Query temperature  
It will appear  
when thermostat detects external sensor.then you can choose  
by rotating button ,and press button to query  
floor temperature(temperature of receiver’s external sensor) .  
This function is only suitable for electric /water floor heating,boiler heating no this function.  
Setting IP code  
Power off state,long press button for 3s to enter into setting interface  
IP high Setting:rotate button to adjust IP high address ( 1 ~ F F ),press button to IP low address setting  
IP low setting:rotate button to adjust IP low address ( 1 ~ F F ),press button to next interface  
Write transceiver IP address:show adjusted IP high address and IP low address,within 10 seconds after transceiver power  
on,press button to send IP address  
Display “55” means that matched successfully  
Communication instruction,be long bright display in normal communication and blinking display in abnormal  
communication  
Transceiver tips  
Transceiver LED display instruction:  
GeneralDetails
NameGLOBAL HY06RF-BW/WW/WE Thermostat User Manual
MakeGLOBAL
LanguageEnglish
FiletypePDF (Download)
File size0.18 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GLOBAL WIFI Digital Heating Thermostat User Manual
GLOBAL WIFI Digital Heating Thermostat User Manual
GLOBAL WiFi Heating Thermostat User Manual
GLOBAL WiFi Heating Thermostat User Manual
GLOBAL HY09RF WIFI Wireless Thermostat User Manual
GLOBAL HY09RF WIFI Wireless Thermostat User Manual
GLOBAL CEG Series Convector with Thermostat Instruction Manual
GLOBAL CEG Series Convector with Thermostat Instruction Manual
GLOBAL Touch Screen Thermostat HY08AC User Manual
GLOBAL Touch Screen Thermostat HY08AC User Manual
GLOBAL Digital Heating Thermostat User Manual
GLOBAL Digital Heating Thermostat User Manual

GLOBAL HY06RF-BW/WW/WE Thermostat User Manual