GENERAL SENNA 270S Smart Room Thermostat User Manual
OPEN WINDOW DETECTION FEATURE
CoolingMode
WARRANTY CONDITIONS
1-The warranty period starts from the invoice date and warranted against
manufacturing defectsfor 2 years.
WARRANTY CERTIFICATE
Your room thermostat measures sudden temperature changes in your house with
its open window detection feature and prevents unnecessary energy consumption
byturning off theheating/cooling unit.
Your Room Thermostat takes the average room temperature of last 40 seconds as
basis. If the room temperature goes above the hysteresis positive temperature
value you set, your Room Thermostat will start the cooling unit. If it goes below the
hysteresis negative temperature value, your Room Thermostat will stop the cooling
2-Devices and apparatus are delivered to the customer in working condition in
our company. On-sitecommissioning is subjectto aservice fee.
3-The repair of the devices and apparatus covered by the warranty is carried
out in our company factory and should send by contracted transportation
company. In on-site services, the transportation and accommodation
expenses of the service personnel belong to the customer. The shift fee during
transportation is added to theservice feeand collectedin advance.
4-The maintenance of devices and apparatus is done in our company. For the
maintenance of the devices and apparatus, the round travel fares belongs to
thecustomer.
Manufacturer
The room thermostat is switched to heating mode while the detection is active. If a
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Adsress: Fatih Mah. 1188 Sk. No:13/A Sarnıç
Gaziemir İzmir-TÜRKİYE
decrease in room temperature of more than
5
degrees is detected within 15
unit. Thus, itensuresthattheroomtemperatureremainswithin acertain range.
Room
Temperature
minutes, the room thermostat switches to the alarm state and turns off the heating
system.
22.5oC
The heating unit remains switched off for 10 minutes unless manual intervention
is performed on the room thermostat. warning appears on the mobile
22.0oC
Set
Temperature
Tel: +90 (232) 457 99 50
21.5oC
A
Fax: +90 (232) 457 91 22
application that an open window has been detected. The heating unit is activated
at the end of 10 minutes. If the room thermostat detects that the window is
closed, the heating unit continues to work. If the temperature continues to drop,
theheating unit is turned off again.
E-Mail: generallife@generallife.com.tr
Authorised Signatory:
Cooling
Unit On
Company Stamp:
5-In case of malfunctioning of the devices and apparatus whose warranty
period continues, it is tested in our company whether the malfunction is
caused by a customer or manufacturer fault, and it is reported with a report
issued byour company.
If the room Thermostat is operated in cooling mode, a sudden temperature rise is
taken into account.
Cooling
Unit Off
Time
This featurecan be enabled/disabled fromtheroomthermostatsettings:
Product
Type: Smart Room Thermostat
Brand: GENERAL Life
Your Room Thermostat sends the last status signal to the Receiverevery3 minutes.
Thus, yourRoom Thermostat and Receiverwork synchronously. If the signal cannot
reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that
the connection is broken and stops the heating/cooling operation for safety
reasons. Likewise, in cases where the electricity comes back after a power failure,
the Receiver does not operate the heating/cooling unit until 'operate' signal reaches
from the Room Thermostat. However, in this case, if the Room Thermostat
continues to operate normally, it will continue to work properly without any need for
intervention since itsends astatussignal to theReceiverevery3 minutes.
Pressthe“ON/OFF”button for 3 seconds while yourdeviceis turned off.
Pressthe“ON/OFF”button until the“ ” menu appears.
Press the “Up” or “Down” button while in the “ ” menu to choose the “
” option and pressthe“ON/OFF”button.
6-In case of detection of manufacturer-induced errors of devices and
apparatus whose warranty period continues, the customer can request a
replacement or repair of the devices and apparatus at full expense by the
manufacturer, unless it's higher than theproduct's price.
” or
“
Model: SENNA 270S SMART
Guarantee Period: 2 Years
Max. Time to Repair: 20 Days
Banderole and Serial Number:
To savethesettingsand exit, pressthe“ON/OFF”button until thedeviceturns off.
The settings you have made are saved. Your device will work with the setting you
Heating/Cooling Unit
7-In the event that the faults of the devices and apparatus whose warranty
period continues are determined as caused by the customer, all expenses
would be belong to thecustomer.
havemade when youopen it.
Off
On
On
Room
Temperature
8-Customers should be aware of damages (if there is any) of product and warn
manufacturer since the day warranty duration starts.If customer do not warn
manufacturerwithknowledge of damage, customerlose therights of article 6.
9-Malfunctions resulting from the use of devices and apparatus contrary to the
mattersstatedin theUserManualarenot covered bythewarranty.
10-Devices and their apparatus are out of warranty if they are beaten, broken or
scratchedbythecustomer.
22oC
FREQUENTLY ASKED QUESTIONS
IsmyRoom Thermostatcompatible withmyheating/cooling unit?
If your heating/cooling unit has On-Off connections, your Room Thermostat is
compatible. You can find information about your heating/cooling unit from your
heating/cooling unit operating manual or fromyourheating/cooling unit service.
17oC
Time
How willIconnect myheating/cooling unit withmy Receiver?
15 min.
25 min.
4
0
m
i
n
.
We recommend that the connection between the Receiver and heating/cooling unit
should be made byprofessionally qualified persons.
11-Damages resulting from the use of devices and apparatus belonging to
other brands and models without the approval of the manufacturer are not
covered bythewarranty.
FACTORY SETTING RESET
You can reset your Room Thermostat to its default factory settings. This operation
resets the mode temperature values, calibration setting, heating/cooling modes,
and hysteresis settings to the factory setting. To reset your room thermostat to
factory setting:
2x0.75mmcableis sufficientfor theReceiver– heating/cooling unit connection.
Connect one end of the cable pair to the room thermostat connection terminals
statedin theuser manual of yourheating/cooling unit.
12-Battery leakage and errors due to rust, oxidation and liquid contact by
working in acidic/ humid environments arenot covered bythewarranty.
13-When the product is not used for a long period (more than 15 days), remove
thebatteries. Otherwise, malfunctions thatwilloccur areout of warranty.
14-Damages that may occur during the transportation of devices and
Connect the other end of the cable pair to COM and NO inputs of the terminal inside
theReceiverasshown in the"RECEIVERWIRINGDIAGRAM" section.
The directionof thecableends does not matter.
While yourdeviceis turned off, pressthe“ON/OFF” button for 3 seconds.
Pressthe“ON/OFF”button until the“
While in the “ ” menu, select the “
and pressthe“ON/OFF”button.
Your devicewillbe turned off and resetto factory settings.
” menu appears.
” option by using the “+” or “-” buttons
Vendor
Title:
apparatus are not covered by the warranty. Customers can take
transportation insurance.
a
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir -
İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its
specificationsbelow is coveredbytheprovisionsof thementioned directive.
15-Damages caused by mains voltage / faulty electrical installation are not
covered bythewarranty.
MODE SETTINGS
There are 2 modes in the Room Thermostat. These are Comfort Mode “
Address:
” and
16-Devices and apparatuses are out of warranty for malfunctions caused by
forcemajeuresuch asfire, flood, earthquakeetc.
Economy Mode “
”. Modes work according to the pre-set temperature values
Brand
ProductName : SENNA 270S SMART
ProductType
: Smart Room Thermostat
: GENERAL Life
adjusted byuser.
Tel:
Fax:
17-All of the devices and apparatuses, including all their parts, are under the
warrantyof our company.
In orderto change thecomfort mode temperaturevalue;
E-Mail:
Pressand hold thecomfort mode button for 3 seconds.
Change thetemperaturevaluebypressing“+” or “-“ buttons.
Invoice Date and Number:
Delivery Time and Place:
Authorised Signatory:
Company Stamp:
The product manufactured by ISIPARK and mentioned above is connected
wirelessly at 2.4 Ghz internet and periodically shares the temperature and status
information withtheserver on theinternet.
18-In case of malfunction of the devices and apparatuses within the warranty
period, the time spent during repairment period is added to the warranty period.
The repair period of the product cannot exceed 20 working days. This period
starts from the date of notification to the service station of the malfunction
related to the product or, in the absence of a service station, to the seller, dealer,
agency, representative, importer or manufacturer of the product. Consumer
can report the problem by; phone, fax, e-mail, registered and reply paid letter or
a similar way. However, in case of a conflict, responsibility of prove is belong to
the customer. If the malfunction of the product is not repaired within 20
working days, the manufacturer-producer or importer; has to allocate another
product with similar features to the use of the consumer until the repair of the
product is completed,
Press the comfort mode button once to save the changes you have made or wait
10seconds.
Compatible Directives:
In orderto change theeconomy mode temperaturevalue;
Radio and Telecommunications TerminalEquipmentRegulation
2014/53/EU(ETSI EN301489-1 V2.2.3(2019-11),
Pressand hold theeconomy mode button for 3 seconds.
Change thetemperaturevaluebypressing“+” or “-” buttons.
Press the economy mode button once to savethe changes you havemade or wait
10seconds.
ETSI EN301489-17 V3.2.4(2020-09), EN300220-1V3.1.1,
EN300220-2V3.2.1(2018-06), EN62479:2010, EN62368-1:2014+A11:2017)
Electromagnetic Compatibility Regulation 2014/30/EU
Product
Type: Smart Room Thermostat
Brand: GENERAL Life
You can use the“+” and “-” buttons to use theRoom Thermostatmanually.
(ETSI EN301489-1 V2.2.3, ETSI EN301489-3 V2.1.1)
STAMP
ROOM THERMOSTAT WORKING LOGIC
HeatingMode
Low Voltage Directive2014/35/EU(EN60730-2-9)
Supplementary Information: Mentioned product can be used with combi boilers
with on / off output and compatibility with the directive only covers the product.
ISIPARK is not responsible for the compliance of the entire system with the
directive. This declaration does not apply when changes are made to the product
without obtaining our consent.
Model: SENNA 270S SMART
Your room thermostat takes the average room temperature of the last 40 seconds
as the basis. If the room temperature goes above the hysteresis positive
temperaturevalue you set, your room thermostat will stop the heating unit. If it goes
below the hysteresis negative temperature value, your room thermostat will start
the heating unit. Thus, it ensures that the room temperature remains within a
certain range.
19-Although theconsumer uses his/her repairrights,
-If the product breaks down for 4 times in a year or 6 times in warranty duration
and these problems effects main purpose of the product. (starting from
delivery timeduring warranty.)
-Exceeding themaximum timerequired for repair,
-In the event that the service station is not available, if it is determined that the
repair of the defect is not possible with the report prepared (in order) by one of
the seller, dealer, agency, representative, importer or manufacturer, a refund or
apricediscount attherateof defectcan be requested.
Room
Temperature
22.5oC
Set
Temperature
22.0oC
21.5oC
20-The customer can make complaints and appeals to consumer courts or
consumer arbitrationcommittees.
Heating
Unit On
Isıpark reserves the rights of changing product specifications and user
manuals.
21-The warranty document must be kept by the customer during the warranty
period. If the document is lost, a second document will not be issued. In case of
loss, repairand replacementof devicesand apparatuswill be made for afee.
*For allchanges,youmayvisitgenerallife.com.tr
Heating
Unit Off
Time
5
6
7
8
| General | Details |
|---|---|
| Name | GENERAL SENNA 270S Smart Room Thermostat User Manual |
| Make | GENERAL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.17 MB |

GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL HT250S Digital Room Thermostat User Manual

GENERAL FH260S Underfloor Heating Thermostat User Manual

GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual

GENERAL HT250 Digital Room Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual

GENERAL SENNA 300 Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Smart Room Thermostat User Manual

GENERAL MITRA 250S Digital Room Thermostat User Manual