Home > GENERAL LIFE > GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual

GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual

ScreenIndicators  
Warning!  
Operations within the heating / cooling unit or the electrical installation must be  
carriedout byprofessionally qualified persons.  
ENGLISH  
1
2
8
DIGITAL ROOM THERMOSTAT  
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER  
9
10  
Primarily press the sync button of the Receiver for 2 seconds and see blinking  
greenlight oftheReceiver.  
3
4
generallife.com.tr  
While yourdeviceis turned off, pressand hold the"On/Off" button for 3 seconds.  
Pressthebutton until the“  
” menu appears.  
BATTERY PLACEMENT  
Press the “+” or “-” button of your Room Thermostat while the LED is flashing  
green.  
5
SENNA 300S RF USER MANUAL  
6
7
Ifthepairing issuccessful, thegreenashing LEDon theReceiverwillbe steady.  
Receiverand Room Thermostathavebeen pairedto each other.  
GENERAL SPECIFICATIONS  
1
2
3
4
5
6
7
8
Hour Indicator  
Day Indicator  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
SENNA 300S RF is a wireless room thermostat. The user can adjust the room  
temperature with the required temperature and get more comfortable and  
economic heating/cooling.  
Temperature sensors which are used in Room Thermostats are highly sensitive.  
You may need to calibrate your Room Thermostat if you would like to get the same  
temperaturevalueswithother thermometersin yourliving space.  
Room Temperature  
Set Temperature  
Dailyand WeeklyProgramming  
Economy Mode  
Comfort Mode  
While yourdeviceis turned off, pressand hold theOn/Off“ button for 3 seconds.  
Press the "On/Off" button until the “ ” menu appears. In order to see the  
DifferentMode Options (Comfort, Economy)  
Heating Calibration  
ON/OFFControl  
WirelessConnection  
Weekly Program Mode  
Battery Indicator  
Heating Indicator  
desired temperature, set the temperature difference by pressing the  
Heating/Cooling Option  
TPIAlgorithm  
“Temperature Adjustment Buttons”. This value can be arranged between “-8° C"  
PreciseTemperatureMeasurement  
As shown in the picture above, press the screwdriver forward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace both  
batteries at the same time. Then align the frontpart of your Room Thermostat to the  
backand squeezeittowardstheback.  
and “+8° C".  
9
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
SENNA 300S RF AND EQUIPMENTS  
SENNA 300S RF Room Thermostat  
In order to save the settings and exit, press the "On/Off" button until the device  
turns off.  
Holder  
Alkaline  
Battery  
Note:Recommended temperaturecalibration is “0.0°C”.  
10  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Low Battery Warning: When the “  
” icon appears on the screen, it means “low  
FACTORY SETTINGS RESET  
RECEIVER  
battery warning”. It is recommended to replace the batteries when this warning  
appears.  
You can reset your Room Thermostat to its default factory settings. This operation  
resets the mode temperature values, calibration setting and heating/cooling  
modes to factory setting. In orderto resetyourRoom Thermostatto factory setting:  
1-Manual Operation Button:  
By disabling the Receiver, it enables you to use  
your boiler manually.  
2-Pairing Button:  
Warning: When the product is not used for a long period (more than 15 days), remove  
thebatteries. Otherwise, malfunctions thatmay occurwouldbeoutof warranty.  
Pleasethrowyourdead batteries into thewastebin forbatteries.  
1
2
3
While yourdeviceis turned off, pressand hold theOn/Off” button for 3 seconds.  
Dowels and Screws  
Receiver  
PresstheOn/Off” button untilthe“  
While in the “ ” menu, select the “  
and presstheOn/Off” button.  
Your devicewillbe turned off and resetto factory settings.  
” menu appears.  
Allows to pair the Receiver with the Room  
Thermostat.  
3-Receiver LED Light  
4-Receiver Power Cable Input  
5-Boiler Connection Cable Input  
” option by using the +” or “-” buttons  
RECEIVER PLACEMENT  
The important things to note for the Receiver placement is  
avoiding physical contact between the Receiver and  
heating/cooling unit, and protecting it against materials  
such asliquid, dust etc.  
DAY AND HOUR SETTINGS  
While your Room Thermostat is on, keep pressing the “Weekly Programbutton  
for 3 seconds.  
TECHNICAL DATA  
Room Thermostat  
At the first screen that appears, hour part will be blinking. You may set the time  
withthe+” and“-” buttons.  
The devices should be placed in order to minimize the damage to the received and  
transmittedsignals bypayingattentiontothefollowingpoints;  
Dimensions  
Operating Current  
85mm / 125mm / 19mm  
3V DC (2 x AAA alkaline battery)  
0.1oC  
4
5
After setting the time, the “Heating & Cooling Optionbutton needs to be pressed  
once. For minute setting, minute part will be blinking. You mayset the minute with  
the+” and“-” buttons.  
The devicesshould not be mounted on metalsurfaces.  
Temperature Measurement Accuracy  
Operating Temperature Range  
Battery Life  
RECEIVER LED DESCRIPTIONS  
(5oC) – (30oC)  
The devices should not be installed close to electrical cables and electronic  
equipment such ascomputers and televisionunits.  
Steady Red  
Receiver has power but Receiver and  
Room Thermostat are not paired.  
Waiting for pairing signal from Room Thermostat.  
Receiver and Room Thermostat are paired.  
Boiler is not operating.  
1 Years (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
After setting the minute, the “Heating & Cooling Optionbutton needs to be  
pressedonce to setthedayof theweek.  
The devices should not be installed near large metal structures or other building  
materialsusing finemetalmeshes such asspecialglass or specialconcrete.  
Distance between the Room Thermostat and the Receiver should not exceed 20  
metersor 2 floors.  
Operating Temperature  
Storage Temperature  
Blinking Green  
Steady Green  
Mondayhas setastherstdayof theweekand indicated withnumber1".  
Numbers indicate the following days respectively 2-Tuesday, 3-Wednesday, 4-  
Thursday, 5-Friday, 6-Saturdayand 7-Sunday  
Receiver  
3 Short Orange  
Blinking  
Operate the boiler signal has reached to the  
Receiver.  
Receivermust be installed atleast50cmawayfromtheheating/cooling unit.  
Dimensions  
Operation Current  
Relay NO Switching Current  
90mm / 90mm / 25mm  
230V AC  
When setting is done, you may exit by pressing the “Weekly Program” button for 3  
seconds.  
Steady Orange  
3 Short Green  
Blinking  
Boiler is operating.  
RECEIVER SETUP  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
(-20oC) – (+60oC)  
Shut the boiler down signal has reached to the  
Receiver.  
First, shut down your heating/cooling unit and your heating/cooling unit's power  
sourcewithallelectricalcurrent(fuse, socketetc.)  
MODE SETTING  
MODES  
Storage Temperature  
Blinking Orange  
Boiler is operating in manual mode.  
As shown in the connection diagram, connect one end of the heating/cooling unit  
connection cableto theCOMand theother to theNO input of theReceiver.  
Connect the other ends of the cable -which youconnected to the Receiverto room  
thermostat connection terminal as shown in your heating/cooling unit's user  
manual.  
ROOM THERMOSTAT  
Buttons Functions  
Blinking Red  
Receiver did not get a signal from the  
Room Thermostat for 22 minutes or longer and  
boiler has shut down.  
PRESET MODES  
WEEKLY  
PROGRAM  
MODE  
MANUAL MODE  
Comfort  
Mode  
Economy  
Mode  
You must first connect the Receiver power cable to the Receiver and then to the  
fuse to which theheating/cooling unit is connected.  
ROOM THERMOSTAT PLACEMENT  
1
Room Thermostat needs to be placed in the room which is used most frequently.  
For instance; living room or lounge. Placing the Room Thermostat in a spot that  
have air circulation like entrance of a room or side of window should be avoided.  
Also anywhere close to heating/cooling units such as radiator, stove and spots  
which get direct sun lights would not be suitable. Room Thermostat needs to be  
located above the floor 150 cm height. Few trials may be made to find the most  
convenientspot.  
Your Room Thermostat has 4 different modes. 3 of them (Comfort and Economy  
Mode) are preset modes. Other modes are manual mode and weekly program  
mode.  
After completing the cable connection process, firstly turn on your fuse and then  
yourheating/cooling unit.  
2
3
By pressing the Receiver's manual usage button for 2 seconds, you should see  
the Orange Light blinking on the Receiver. In this way, after making sure that the  
heating/cooling unit is operating, press the same button again for 2 seconds and  
seethattheOrange LEDturns off.  
In preset modes, temperature values are based on user's choices which have been  
set in the beginning. Manual mode allows the Room Thermostat to operate within  
the temperature which is required and set directly by user. Weekly Program mode  
continues to workaccordingto theweeklyschedule determined bytheuser.  
In orderto change thetemperaturevaluesof presetmodes:  
4
Setup theRoom Thermostatto pair theReceiverwiththeRoom Thermostat.  
5
6
AC  
RECEIVER WIRING DIAGRAM  
Press and hold the “Mode” button for 3 seconds while your Room Thermostat is  
on.  
COM  
NO  
(230V)  
1
2
3
4
5
6
ON/OFF Button  
Weekly Program Button  
Mode Button  
Comfort Mode temperature value will appear. You may adjust the temperature  
valueof Comfort Mode bypressingthe+” and “-” buttons.  
When setting is done, you may adjust the temperature value of Economy Mode  
withthe+” and “-” buttons bypressingtheModebutton again.  
You mayexitthesettingscreenbypressingtheModebutton 3 seconds.  
In order to change the manual mode temperature, press the “+” or “-” button while  
in the main screen. The Room Thermostat will switch to Manual Mode once  
pressedthe+” or “-” button.  
Heating & Cooling Option  
Temperature Adjustment (Increasing)  
Temperature Adjustment (Decreasing)  
HEATING/COOLING UNIT  
You maypresstheModebutton to switchto theother modes.  
1
2
3
4
GeneralDetails
NameGENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Warning: Operations within the heating/cooling unit or the electrical installation must be carried out by professionally qualified persons. Digital room thermostat pairing instructions include pressing the sync button of the receiver for 2 seconds. If the pairing is successful, the green flashing LED on the receiver will be steady. The SENNA 300S RF is a wireless room thermostat that allows users to adjust room temperature for comfort and economic heating/cooling. Temperature sensors in room thermostats are highly sensitive, and calibration may be necessary for accuracy. Battery placement involves inserting 2 new AAA alkaline batteries in the correct direction. Low battery warning is indicated when the low battery icon appears on the screen. Factory settings can be reset, which will restore the thermostat to its default settings. Receiver placement should avoid physical contact with heating/cooling units and protect against liquids and dust. The room thermostat should be placed in frequently used rooms, avoiding areas with direct sunlight or close proximity to heating/cooling units.
  • Page 2: You may set the operating schedule of your room thermostat with a weekly program. The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. Your room thermostat takes the average room temperature of the last 40 seconds as a basis. With the TPI algorithm, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Seven different temperature values can be set for each day in weekly programming. In order to set the weekly schedule, press and hold the “Weekly Program” button for 3 seconds while your room thermostat is on. If the signal cannot reach the receiver from the room thermostat for 22 minutes, it perceives that the connection is broken and stops the heating/cooling operation for safety reasons. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault. The learning process of the TPI room thermostats should be considered as 7 days. The customer can make complaints and appeals to consumer courts or consumer arbitration committees.