Home > GENERAL LIFE > GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual
GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual
ScreenIndicators
Warning!
Operations within the heating / cooling unit or the electrical installation must be
carriedout byprofessionally qualified persons.
ENGLISH
1
2
8
DIGITAL ROOM THERMOSTAT
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER
9
10
Primarily press the sync button of the Receiver for 2 seconds and see blinking
greenlight oftheReceiver.
3
4
generallife.com.tr
While yourdeviceis turned off, pressand hold the"On/Off" button for 3 seconds.
Pressthebutton until the“
” menu appears.
BATTERY PLACEMENT
Press the “+” or “-” button of your Room Thermostat while the LED is flashing
green.
5
SENNA 300S RF USER MANUAL
6
7
Ifthepairing issuccessful, thegreenflashing LEDon theReceiverwillbe steady.
Receiverand Room Thermostathavebeen pairedto each other.
GENERAL SPECIFICATIONS
1
2
3
4
5
6
7
8
Hour Indicator
Day Indicator
ROOM THERMOSTATTEMPERATURE CALIBRATION
SENNA 300S RF is a wireless room thermostat. The user can adjust the room
temperature with the required temperature and get more comfortable and
economic heating/cooling.
Temperature sensors which are used in Room Thermostats are highly sensitive.
You may need to calibrate your Room Thermostat if you would like to get the same
temperaturevalueswithother thermometersin yourliving space.
Room Temperature
Set Temperature
Dailyand WeeklyProgramming
Economy Mode
Comfort Mode
While yourdeviceis turned off, pressand hold the“On/Off“ button for 3 seconds.
Press the "On/Off" button until the “ ” menu appears. In order to see the
DifferentMode Options (Comfort, Economy)
Heating Calibration
ON/OFFControl
WirelessConnection
Weekly Program Mode
Battery Indicator
Heating Indicator
desired temperature, set the temperature difference by pressing the
Heating/Cooling Option
TPIAlgorithm
“Temperature Adjustment Buttons”. This value can be arranged between “-8° C"
PreciseTemperatureMeasurement
As shown in the picture above, press the screwdriver forward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline
batteries in the battery housing with the correct battery direction. Replace both
batteries at the same time. Then align the frontpart of your Room Thermostat to the
backand squeezeittowardstheback.
and “+8° C".
9
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator is steady, the heating unit is not working.
Cooling Indicator
SENNA 300S RF AND EQUIPMENTS
SENNA 300S RF Room Thermostat
In order to save the settings and exit, press the "On/Off" button until the device
turns off.
Holder
Alkaline
Battery
Note:Recommended temperaturecalibration is “0.0°C”.
10
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
Low Battery Warning: When the “
” icon appears on the screen, it means “low
FACTORY SETTINGS RESET
RECEIVER
battery warning”. It is recommended to replace the batteries when this warning
appears.
You can reset your Room Thermostat to its default factory settings. This operation
resets the mode temperature values, calibration setting and heating/cooling
modes to factory setting. In orderto resetyourRoom Thermostatto factory setting:
1-Manual Operation Button:
By disabling the Receiver, it enables you to use
your boiler manually.
2-Pairing Button:
Warning: When the product is not used for a long period (more than 15 days), remove
thebatteries. Otherwise, malfunctions thatmay occurwouldbeoutof warranty.
Pleasethrowyourdead batteries into thewastebin forbatteries.
1
2
3
While yourdeviceis turned off, pressand hold the“On/Off” button for 3 seconds.
Dowels and Screws
Receiver
Pressthe“On/Off” button untilthe“
While in the “ ” menu, select the “
and pressthe“On/Off” button.
Your devicewillbe turned off and resetto factory settings.
” menu appears.
Allows to pair the Receiver with the Room
Thermostat.
3-Receiver LED Light
4-Receiver Power Cable Input
5-Boiler Connection Cable Input
” option by using the “+” or “-” buttons
RECEIVER PLACEMENT
The important things to note for the Receiver placement is
avoiding physical contact between the Receiver and
heating/cooling unit, and protecting it against materials
such asliquid, dust etc.
DAY AND HOUR SETTINGS
While your Room Thermostat is on, keep pressing the “Weekly Program” button
for 3 seconds.
TECHNICAL DATA
Room Thermostat
At the first screen that appears, hour part will be blinking. You may set the time
withthe“+” and“-” buttons.
The devices should be placed in order to minimize the damage to the received and
transmittedsignals bypayingattentiontothefollowingpoints;
Dimensions
Operating Current
85mm / 125mm / 19mm
3V DC (2 x AAA alkaline battery)
0.1oC
4
5
After setting the time, the “Heating & Cooling Option” button needs to be pressed
once. For minute setting, minute part will be blinking. You mayset the minute with
the“+” and“-” buttons.
The devicesshould not be mounted on metalsurfaces.
Temperature Measurement Accuracy
Operating Temperature Range
Battery Life
RECEIVER LED DESCRIPTIONS
(5oC) – (30oC)
The devices should not be installed close to electrical cables and electronic
equipment such ascomputers and televisionunits.
Steady Red
Receiver has power but Receiver and
Room Thermostat are not paired.
Waiting for pairing signal from Room Thermostat.
Receiver and Room Thermostat are paired.
Boiler is not operating.
1 Years (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
After setting the minute, the “Heating & Cooling Option” button needs to be
pressedonce to setthedayof theweek.
The devices should not be installed near large metal structures or other building
materialsusing finemetalmeshes such asspecialglass or specialconcrete.
Distance between the Room Thermostat and the Receiver should not exceed 20
metersor 2 floors.
Operating Temperature
Storage Temperature
Blinking Green
Steady Green
Mondayhas setasthefirstdayof theweekand indicated withnumber“1".
Numbers indicate the following days respectively 2-Tuesday, 3-Wednesday, 4-
Thursday, 5-Friday, 6-Saturdayand 7-Sunday
Receiver
3 Short Orange
Blinking
Operate the boiler signal has reached to the
Receiver.
Receivermust be installed atleast50cmawayfromtheheating/cooling unit.
Dimensions
Operation Current
Relay NO Switching Current
90mm / 90mm / 25mm
230V AC
When setting is done, you may exit by pressing the “Weekly Program” button for 3
seconds.
Steady Orange
3 Short Green
Blinking
Boiler is operating.
RECEIVER SETUP
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
(-20oC) – (+60oC)
Shut the boiler down signal has reached to the
Receiver.
First, shut down your heating/cooling unit and your heating/cooling unit's power
sourcewithallelectricalcurrent(fuse, socketetc.)
MODE SETTING
MODES
Storage Temperature
Blinking Orange
Boiler is operating in manual mode.
As shown in the connection diagram, connect one end of the heating/cooling unit
connection cableto theCOMand theother to theNO input of theReceiver.
Connect the other ends of the cable -which youconnected to the Receiverto room
thermostat connection terminal as shown in your heating/cooling unit's user
manual.
ROOM THERMOSTAT
Buttons Functions
Blinking Red
Receiver did not get a signal from the
Room Thermostat for 22 minutes or longer and
boiler has shut down.
PRESET MODES
WEEKLY
PROGRAM
MODE
MANUAL MODE
Comfort
Mode
Economy
Mode
You must first connect the Receiver power cable to the Receiver and then to the
fuse to which theheating/cooling unit is connected.
ROOM THERMOSTAT PLACEMENT
1
Room Thermostat needs to be placed in the room which is used most frequently.
For instance; living room or lounge. Placing the Room Thermostat in a spot that
have air circulation like entrance of a room or side of window should be avoided.
Also anywhere close to heating/cooling units such as radiator, stove and spots
which get direct sun lights would not be suitable. Room Thermostat needs to be
located above the floor 150 cm height. Few trials may be made to find the most
convenientspot.
Your Room Thermostat has 4 different modes. 3 of them (Comfort and Economy
Mode) are preset modes. Other modes are manual mode and weekly program
mode.
After completing the cable connection process, firstly turn on your fuse and then
yourheating/cooling unit.
2
3
By pressing the Receiver's manual usage button for 2 seconds, you should see
the Orange Light blinking on the Receiver. In this way, after making sure that the
heating/cooling unit is operating, press the same button again for 2 seconds and
seethattheOrange LEDturns off.
In preset modes, temperature values are based on user's choices which have been
set in the beginning. Manual mode allows the Room Thermostat to operate within
the temperature which is required and set directly by user. Weekly Program mode
continues to workaccordingto theweeklyschedule determined bytheuser.
In orderto change thetemperaturevaluesof presetmodes:
4
Setup theRoom Thermostatto pair theReceiverwiththeRoom Thermostat.
5
6
AC
RECEIVER WIRING DIAGRAM
Press and hold the “Mode” button for 3 seconds while your Room Thermostat is
on.
COM
NO
(230V)
1
2
3
4
5
6
ON/OFF Button
Weekly Program Button
Mode Button
Comfort Mode temperature value will appear. You may adjust the temperature
valueof Comfort Mode bypressingthe“+” and “-” buttons.
When setting is done, you may adjust the temperature value of Economy Mode
withthe“+” and “-” buttons bypressingthe“Mode”button again.
You mayexitthesettingscreenbypressingthe“Mode”button 3 seconds.
In order to change the manual mode temperature, press the “+” or “-” button while
in the main screen. The Room Thermostat will switch to Manual Mode once
pressedthe“+” or “-” button.
Heating & Cooling Option
Temperature Adjustment (Increasing)
Temperature Adjustment (Decreasing)
HEATING/COOLING UNIT
You maypressthe“Mode”button to switchto theother modes.
1
2
3
4
| General | Details |
|---|---|
| Name | GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.24 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE SENNA 300S RF Wireless Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Warning: Operations within the heating/cooling unit or the electrical installation must be carried out by professionally qualified persons. Digital room thermostat pairing instructions include pressing the sync button of the receiver for 2 seconds. If the pairing is successful, the green flashing LED on the receiver will be steady. The SENNA 300S RF is a wireless room thermostat that allows users to adjust room temperature for comfort and economic heating/cooling. Temperature sensors in room thermostats are highly sensitive, and calibration may be necessary for accuracy. Battery placement involves inserting 2 new AAA alkaline batteries in the correct direction. Low battery warning is indicated when the low battery icon appears on the screen. Factory settings can be reset, which will restore the thermostat to its default settings. Receiver placement should avoid physical contact with heating/cooling units and protect against liquids and dust. The room thermostat should be placed in frequently used rooms, avoiding areas with direct sunlight or close proximity to heating/cooling units.
- Page 2: You may set the operating schedule of your room thermostat with a weekly program. The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. Your room thermostat takes the average room temperature of the last 40 seconds as a basis. With the TPI algorithm, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Seven different temperature values can be set for each day in weekly programming. In order to set the weekly schedule, press and hold the “Weekly Program” button for 3 seconds while your room thermostat is on. If the signal cannot reach the receiver from the room thermostat for 22 minutes, it perceives that the connection is broken and stops the heating/cooling operation for safety reasons. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault. The learning process of the TPI room thermostats should be considered as 7 days. The customer can make complaints and appeals to consumer courts or consumer arbitration committees.