Home > GENERAL LIFE > GENERAL LIFE MITRA-261S Smart Room Thermostat User Manual
GENERAL LIFE MITRA-261S Smart Room Thermostat User Manual
Heating/Cooling Unit
On
Off
On
Room
Temperature
ROOM THERMOSTATTEMPERATURE CALIBRATION
DECLARATION OF CONFORMITY
18-In case of malfunction of the devices and apparatuses within the warranty
period, the time spent during repairment period is added to the warranty period. The
repair period of the product cannot exceed 20 working days. This period starts from
the date of notification to the service station of the malfunction related to the
Temperature sensors which are used in room thermostats are highly sensitive. You
may need to calibrate your room thermostat if you would like to get the same
temperaturevaluesasother thermometersin yourliving space.
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir -
İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its
specificationsbelow is coveredbytheprovisionsof thementioned directive.
22oC
product or, in the absence of
a
service station, to the seller, dealer, agency,
While yourdeviceis turned off, pressthebutton for 3 seconds.
Brand
: GENERAL Life
representative, importer or manufacturer of the product. Consumer can report the
problem by; phone, fax, e-mail, registered and reply paid letter or a similar way.
However, in case of a conflict, responsibility of prove is belong to the customer. If
the malfunction of the product is not repaired within 20 working days, the
manufacturer-producer or importer; has to allocate another product with similar
featuresto theuse of theconsumer until therepairof theproductis completed,
19-Although theconsumer uses his/her repairrights,
Press the button until the “
” menu appears. To see the desired temperature,
17oC
ProductName : MITRA 261S SMART
set the temperaturedifferencebyturning the button right or left. This valuecan be
arranged between“-8°C" and “+8°C".
ProductType : Digital Room Thermostat
Time
The product manufactured by ISIPARK and mentioned above is connected
wirelessly at 2.4 Ghz internet and periodically shares the temperature and status
information withtheserver on theinternet.
To savethesettingsand exit, pressthebutton until thedeviceturns off.
15 min.
25 min.
40 min.
Note:Recommended temperaturecalibration is“0.0oC”.
FACTORY SETTING RESET
Compatible Directives:
ROOM THERMOSTAT HEATING / COOLING MODES
Your Room Thermostat has heating and cooling modes. In order to switch easily
betweenheating and cooling modes:
You can reset your Room Thermostat to its default factory settings. This operation
resets the calibration setting, heating/coling modes and hysteresis settings to
factory setting. To resetyourRoom Thermostatto factory setting:
-If the product breaks down for 4 times in a year or 6 times in warranty duration and
theseproblemseffectsmain purpose of theproduct.
Radio and Telecommunications TerminalEquipmentRegulation
2014/53/EU(ETSI EN301489-1 V2.2.3(2019-11),
(starting fromdelivery timeduring warranty.)
ETSI EN301489-17 V3.2.4(2020-09), EN300220-1V3.1.1,
EN300220-2V3.2.1(2018-06), EN62479:2010, EN62368-1:2014+A11:2017)
ElectromagneticCompatibility Regulation 2014/30/EU
(ETSI EN301489-1 V2.2.3, ETSI EN301489-3 V2.1.1)
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.
Pressthebutton until the“ ” menu appears.
While in the “ ” menu, turn the button to right or left in order to select
- Exceedingthemaximum timerequiredfor repair,
Pressthebutton until the“
You can switch between “
thebutton to right or leftin the“
” menu appears.
” (heating) and “
” menu.
- In the event that the service station is not available, if it is determined that the
repair of the defect is not possible with the report prepared (in order) by one of the
seller, dealer, agency, representative, importer or manufacturer, a refund or a price
discount attherateof defectcan be requested.
” (cooling) modes by turning
“
”
option and pressthebutton.
Low Voltage Directive2014/35/EU(EN60730-2-9)
To savethesettingsand exit, pressthebutton until thedeviceturns off.
The settings you have made have been saved. Once you turned on your device, it
willoperatewiththechanged settings.
Your devicewillbe turned off and resetto factory settings.
Supplementary Information: Mentioned product can be used with combi boilers
with on / off output and compatibility with the directive only covers the product.
ISIPARK is not responsible for the compliance of the entire system with the
directive. This declaration does not apply when changes are made to the product
without obtaining our consent.
20-The customer can make complaints and appeals to consumer courts or
consumer arbitrationcommittees.
ROOM THERMOSTAT WORKING LOGIC
HeatingMode
21-The warranty document must be kept by the customer during the warranty
period. If the document is lost, a second document will not be issued. In case of
loss, repairand replacementof devicesand apparatus willbe made for afee.
ROOM THERMOSTAT HYSTERESIS POSITIVE MENU
Your room thermostat takes the average room temperature of last 40 seconds as
basis. If the room temperature goes above the hysteresis positive temperature
value you set, your Room Thermostat will stop the heating unit. If it goes below the
hysteresisnegativetemperaturevalue, yourRoom Thermostat will start the heating
The hysteresis positive factory setting of your room thermostat is 0.5°C. This value
may be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is
0.5°C, if the room temperature goes above 0.5°C of the set temperature, your room
thermostat will send a signal to your heating/cooling unit. For instance, when you
set your room thermostat to 22.0°C, if the room temperature goes above 22.5°C, on
the heating mode your heating unit will stop working; on the cooling mode your
cooling unit willstart working. To change thehysteresispositivesetting:
unit. Thus, itensuresthattheroomtemperatureremainswithin acertain range.
Room
Temperature
22.5oC
Set
Temperature
22.0oC
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.
Pressthebutton until the“ ” menu appears.
Adjust the operating sensitivity by turning the button right or left in the “
21.5oC
WARRANTY CERTIFICATE
WARRANTY CONDITIONS
1-The warranty period starts from the invoice date and warranted against
manufacturing defectsfor 2 years.
”
Heating
Unit On
Manufacturer
hysteresis positive menu. To save the settings and exit, press the button until the
deviceturns off.
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Adsress: Fatih Mah. 1188 Sk. No:13/A Sarnıç
Gaziemir İzmir-TÜRKİYE
Tel: +90 (232) 457 99 50
Fax: +90 (232) 457 91 22
E-Mail: generallife@generallife.com.tr
Authorised Signatory:
2-Devices and apparatus are delivered to the customer in working condition in our
company. On-sitecommissioning is subjectto aservice fee.
Changes have been saved. Your room thermostat will be working with set
operating sensitivitywhen youopen yourdevice.
Heating
Unit Off
CoolingMode
Time
3-The repair of the devices and apparatus covered by the warranty is carried out in
our company factory and should send bycontracted transportation company. In on-
site services, the transportation and accommodation expenses of the service
personnel belong to the customer. The shift fee during transportation is added to
theservice feeand collectedin advance.
ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU
Your Room Thermostat takes the average room temperature of last 40 seconds as
basis. If the room temperature goes above the hysteresis positive temperature
value you set, your Room Thermostat will start the cooling unit. If it goes below the
hysteresis negative temperature value, your Room Thermostat will stop the cooling
unit. Thus, itensuresthattheroomtemperatureremainswithin acertain range.
The hysteresis negative factorysettingof your room thermostatis -0.5°C.This value
may beadjustedbetween“-0.1°C”and“-2.0°C”.Whilethehysteresisnegativevalueis
-0.5°C, if the room temperature goes below 0.5°C of the set temperature, your room
thermostat will send a signal to your heating/cooling unit. For instance, when you
set your room thermostatto 22°C, if the room temperature goesbelow21.5°C,on the
heating mode your heating unit will start working; on the cooling mode your cooling
unitwillstopworking.To changethehysteresisnegativesetting:
Company Stamp:
4-The maintenance of devices and apparatus is done in our company. For the
maintenance of the devices and apparatus, the round travel fares belongs to the
customer.
Room
Temperature
Product
Type: Digital Room Thermostat
Brand: GENERAL Life
5-In case of malfunctioning of the devices and apparatus whose warranty period
continues, it is tested in our company whether the malfunction is caused by a
customer or manufacturer fault, and it is reported with a report issued by our
company.
22.5oC
22.0oC
Set
Temperature
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.
Pressthebutton until the“ ” menu appears.
Adjust the operating sensitivity by turning the button right or left in the“
21.5oC
Model: MITRA 261S SMART
Guarantee Period: 2 Years
Max. Time to Repair: 20 Days
Banderole and Serial Number:
”
6-In case of detection of manufacturer-induced errors of devices and apparatus
whose warranty period continues, the customer can request a replacement or
repair of the devices and apparatus at full expense by the manufacturer, unless it's
higher than theproduct's price
Cooling
Unit On
hysteresisnegative menu. To savethe settings and exit, press the button until the
deviceturns off.
Changes have been saved. Your room thermostat will be working with set
operating sensitivitywhen youopen yourdevice.
Cooling
Unit Off
7-In the event that the faults of the devices and apparatus whose warranty period
continues are determined as caused by the customer, all expenses would be belong
to thecustomer.
Time
Vendor
Title:
OPEN WINDOW DETECTION FEATURE
Your Room Thermostat sends the last status signal to the Receiverevery3 minutes.
Thus, yourRoom Thermostat and Receiverwork synchronously. If the signal cannot
reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that
the connection is broken and stops the heating/cooling operation for safety
reasons. Likewise, in cases where the electricity comes back after a power failure,
the Receiver do not operate the heating/cooling unit until 'operate' signal reaches
fromtheRoom Thermostat.
Your room thermostat measures sudden temperature changes in your house with
its open window detection feature and prevents unnecessary energy consumption
byturning off theheating/cooling unit.
8-Customers should be aware of damages (if there is any) of product and warn
manufacturer since the day warranty duration starts.If customer do not warn
manufacturerwithknowledge of damage, customerlose therights of article 6.
9-Malfunctions resulting from the use of devices and apparatus contrary to the
mattersstatedin theUserManual arenot coveredbythewarranty.
10-Devices and their apparatus are out of warranty if they are beaten, broken or
scratchedbythecustomer.
Address:
The room thermostat is switched to heating mode while the detection is active. If a
Tel:
Fax:
decrease in room temperature of more than
5
degrees is detected within 15
E-Mail:
minutes, the room thermostat switches to the alarm state and turns off the heating
system.
Invoice Date and Number:
Delivery Time and Place:
Authorised Signatory:
Company Stamp:
However, in this case, if the Room Thermostat continues to operate normally, it will
continue to work properly without any need for intervention since it sends a status
signal to theReceiverevery3 minutes.
11-Damages resulting from the use of devices and apparatus belonging to other
brands and models without the approvalof the manufacturer are not coveredby the
warranty.
The heating unit remains switched off for 10 minutes unless manual intervention is
performed on the room thermostat. A warning appears on the mobile application
that an open window has been detected. The heating unit is activated at the end of
10 minutes. If the room thermostat detects that the window is closed, the heating
unit continues to work. If the temperature continues to drop, the heating unit is
turned off again.
12-Battery leakage and errors due to rust, oxidation and liquid contact by working in
acidic/ humid environmentsarenot coveredbythewarranty.
13-When the product is not used for a long period (more than 15 days), remove the
batteries. Otherwise, malfunctions thatwilloccur areout of warranty.
14-Damages that may occur during the transportation of devices and apparatus are
not coveredbythewarranty. Customers can takeatransportation insurance.
15-Damages caused by mains voltage / faulty electrical installation are not covered
bythewarranty.
FREQUENTLY ASKED QUESTIONS
IsmyRoom Thermostatcompatible withmyheating/cooling unit?
If your heating / cooling unit has on-off connections, your Room Thermostat is
compatible. You can find information about your heating / cooling unit from your
heating / cooling unit operating manual or fromyourheating / cooling unit service.
Product
If the room Thermostat is operated in cooling mode, a sudden temperature rise is
taken into account.
Type: Digital Room Thermostat
Brand: GENERAL Life
Model: MITRA 261S SMART
STAMP
How willIconnect myheating/cooling unit withmy Receiver?
This featurecan be enabled/disabled fromtheroomthermostatsettings:
We recommend that the connection between the Receiver and heating/cooling unit
should be made byprofessionally qualified persons.
Pressthebutton for 3 seconds while yourdeviceis turned off.
Pressthebutton until the“ ” menu appears.
16-Devices and apparatuses are out of warranty for malfunctions caused by force
majeuresuch asfire, flood, earthquakeetc.
2x0.75mmcableis sufficientfor theReceiver– heating/cooling unit connection.
Connect one end of the cable pair to the room thermostat connection terminals
statedin theuser manual of yourheating/cooling unit.
Press the right or left button while in the “
” menu to choose the “
” or “
”
option and pressthebutton.
17-All of the devices and apparatuses, including all their parts, are under the
warrantyof our company.
To savethesettingsand exit, pressthe“ON/OFF”button until thedeviceturns off.
The settings you have made are saved. Your device will work with the setting you
havemade when youopen it.
Connect the other end of the cable pair to COM and NO inputs of the terminal inside
theReceiverasshown in the"RECEIVERWIRINGDIAGRAM" section.
The directionof thecableends does not matter.
Isıparkreservestherights of changing productspecificationsand user manuals.
*For allchanges,youmayvisitgenerallife.com.tr
5
6
7
8
| General | Details |
|---|---|
| Name | GENERAL LIFE MITRA-261S Smart Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.19 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual