Home > EUROTRONIC > EUROTRONIC Sparmatic COMET Programmable Energy-Saving Radiator Thermostat User Manual
EUROTRONIC Sparmatic COMET Programmable Energy-Saving Radiator Thermostat User Manual
prevents the radiators from freezing.
Further functions
ENVIROMENT PROTECTION
From the date of transposition of the European Directives
2012/19/EU into national law, the following shall apply:
Electrical and electronic devices as well as batteries
must not be disposed with household waste. The
customer is legally obliged to return electrical and electronic
equipment and batteries at the end of their service life to the
public collection points set up for this purpose or the point of
sail. Details are regulated by the respective national law.
Calcification protection function
Timer function
The timer function is selected with the timer-button
To prevent radiator valves from calcifying SPARmatic comet
is submitted to a calcifi cation protection programme once a
week on Friday mornings.
With this function a user-defined temperature for a program-
mable period can be entered. This can be very useful in case
of a party, for example. Press
Cleaning and used devices
First, the time for which
the time programme has been deactivated is shown.
Cleaning
OK
Now, the desired temperature
Confirm with
To clean the SPARmatic comet use only a dry or lightly
wet cloth. Avoid chemical solvent – it can probably
damage the device.
OK
can be set. Confirm with
. In the selected period it is
®
Dispose of packaging sorted by type. Add paperboard
not possible to change the temperature manual, the wheel is
locked. Press Menu and unlock it.
and cardbord to the waste paper, foils to the recyclables
collection. The symbols on the product, the instruction
manual or the packaging refer to these regulations. By
recycling, material utilisatio or other forms of utilisation of old
devices/batteries, you make an important contibution to the
protection of our enviroment.
Used devices
Do not throw old devices and packaging into the household
waste. They can be recycled. You receive further information
at your local government.
Offset
If the perceived temperature significantly differs from the set
thermostat temperature a temperature set up can be execut-
MENU
with the selector
ed. Press
Select the menu item
Adapter
OK
wheel. Confirm with
The degree setting
will
.
flash on the display. Now, set up the desired adaptation for the
Heimeier, Junkers Landys+Gyr,
Declaration of Conformity
temperature (from -5 up to +5°C) with the selector wheel.
MNG, Honeywell, Braukmann
threadmeasure dimension of
M 30x1,5
no adapter
required
The Declaration of Conformity is provided at:
OK
Confirm your entry with
not change!
. The temperature display does
s712.html.
Windowfunction
If you open a window and consequently the temperature drops
signifi cantly, SPARmatic comet will automatically close the
Danfoss RAV (accompanying
pin must be plugged on the
valve tapped)
Guarantee
heating valve in order to save energy. The display will show
.
+ accompanying
pin, only for RAV!
The three-year warranty begins on the day ofpurchase. Please
keep the receipt as evidence of purchase in the fu-
ture. During the guarantee period, defective radiator
thermostats may be
Afterwards, SPARmatic comet will resume normal operation.
OK
For the set up select
in the menu. Confirm with
First, the sensibility is selected with the selector wheel (
=
Danfoss RA
high sensibility,
= medium sensibility (factory preset),
=
sent to the service address below. Please ensure
OK
low sensibility). Confirm with
. Now, you enter the time (10
sufficient postage is paid. A new or repaired device will then be
sent to you free of charge. Following expiry of the guarantee,
you may still send the defective device to the address below for
repairs. Please ensure suffi cient postage is paid. Repairs car-
ried out after the guarantee period are subject to a charge. Your
legal rights are not affected by this guarantee. There is no new
warranty period starting when repairing or replacing the device.
Please note that we only grant warranty on the function of the
device. We will not grant warranty for the interaction between
the thermostat and the bottom part of the valve. The technical
data is only valid for the use of the following valves: Heimeier,
Junkers Landys + Gyr, MNG, Honeywell, Braukmann (measure
of thread M30 x 1,5), Oventrop (M30 x 1,5) Danfoss RA, RAV
and RAVL. Please see the combinations of the devices on our
not issue a guarantee when using the thermostat with valves
which are not mentioned above.
min (factory preset) - 60 min) for which the valve should remain
Danfoss RAVL
OK
closed. Confirm with
.
Travel function
Please remove all the connection pieces of the plastic
adapters before you use one of the attached adapters!
For the time you are absent you can select an individual tem-
perature. After this period the originally defined programme
becomes active again.
MENU
1. Press
.
2.Use tuning wheel to select the menu item
. Confirm
OK
with
.
3. Select with the selector wheel the date and the start time of
Please completely remove the connection rods highlighted
in grey prior to assembly the adapter. You can find additional
brass adapter models that are subject to a charge:
OK
vacation. Confirm with
.
4. Select end of vacation. Date and the start time. Confirm
OK
with
.
OK
5. Set temperature and confirm with the button
.
Hilfe
Symbol appears on the display, when selected holiday
time begins. The symbol disappears automatically when the
Problem Cause
Solution
MENU
time ends. The symbol disapears also by pressing
.
Eurotronic Technology GmbH
Südweg 1
36396 Steinau-Ulmbach
Telefon: 0 66 67 / 9 18 47-0
Servicehotline: 0 66 67 / 9 18 47-17
eMail: support@eurotronic.org
Batteries do not have
Replace batteries.
enough power.
Child lock
Heating
element
does not
warm up.
Is the boiler water
temperature O.K.?
Adjust the temperature
of the boiler water.Re-
move the SPARmatic
comet, move the valve
stem back and forth
You can lock SPARmatic comet to protect the device from
OK
unauthorized activation. Press the buttons
+
at
the same time for about 2 seconds until the signal appears
on the display in order to lock the device. By using this button
combination again the symbol disappears and you release
the lock.
Valve does not open,
is it calcifi ed after
the summer pause /
heating pause?
subject to a charge
*
per hand or with a tool.
pack.-no. 900000415 | stand: 2023/01/17
Heating pause – Closing the SPARmatic comet
Heating
element
does
not cool
down.
Valve does not close
completely. It may be
that the closing point
of your valve seat has times by hand, it may
shifted.
Adapt again (see
“Adapting”) Move the
valve stem several
MENU
Press
Select the menu item
with the selector-
and confirm with
.
OK
wheel. Confirm with
. Select
OK
. Set the temperature on the display to
.
be that adaptation is
impossible because
your valve is calcifi ed
or the seat no longer
performs its function.
The valve is now closed and will work without a time pro-
gramme. The calcification protection function remains active
once a week. After the heating pause you switch in the menu
to the AUTO-mode and the personally set programme will be
executed again.
Pressure
piece falls
out (This
can
also cause
an E1-error)
Due to an end-
lessthread the
pressure piece, which can beadapted by
is situated at the bot- pressing the
tom, can fall out if the point or by removing
Put in the pressure
piece. The device
Daylight saving time
MEN
-
MENU
Press
. Select
with the selector wheel. Confirm with
OK
the
button and select with the selector wheel.
device has not been
affixed on the valve.
and inserting the
batteries. The end-
lessthread is rotating
now and fi xes the
pressure piece again.
Just install it to the
radiator and adapt
it once again.
SPARmatic comet switches automaticly from summer to winter
time.
LCD standby indicator
Press MENU . the menu item
with the selector wheel.
with the
OK
Confirm with the
button and select
/
selector wheel. After about 30 seconds, the LCD indicator swit-
ches into standby mode. By pressing any button, the display
will be activated again. (by removing the battery, standby
mode will be reseted). Increases the battery life time.
By pressing any key the error message will
be deleted in the display and the adapter is
re-started.
-
No adaptation pos-
sible.
SPARmatic comet is
not installed to the
heater.
Is the installation OK?
Going back to factory preset/All reset
Install SPARmatic
comet to the heater.
MENU
Press
. Select the menu item
with the selector wheel.
OK
OK
. SPARmatic
Confirm with
.
flashes, confirm with
comet is reset again. Now, proceed as described for the initial
operation.
Valve stroke is too
short.
Open and close the
valve several times
manually or replace
the batteries.
Freeze protection and calcifi cation protection
function are active automatically:
Motor movement is
not possible.
Does the valve stem
move freely?
Freeze protection function
If the temperature drops below 6°C, SPARmatic comet opens
the valve until the temperature again rises above 8°C. This
| General | Details |
|---|---|
| Name | EUROTRONIC Sparmatic COMET Programmable Energy-Saving Radiator Thermostat User Manual |
| Make | EUROTRONIC |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.37 MB |

EUROTRONIC Programmable Energy-Saving Radiator Thermostat User Manual

eurotronic Comet Zigbee Energy Saving Radiator Thermostat Instruction Manual

EUROTRONIC SPIRIT ZigBee Energy Saving Thermostat User Guide

EUROTRONIC COMET Programmable Energy Saving Radiator Thermostat User Manual

EUROTRONIC Spirit ZigBee Energy Saving Radiator Thermostat User Guide