7.3.1 SW BUILD ID ATTRIBUTE
This attribute defines the firmware version of the device. With every release of new firmware the value of this attribute
will be updated.
7.3.2 PI HEATING DEMAND ATTRIBUTE
The attribute can only be read. An unsigned integer is supplied when reading, this representing the current valve posi-
tion.
0 = Valve closed
7.3.3 ERRORS
Bit
7
6
5
4
3
2
1
0
Error reserved reserved Valve not
moving
(E3)
Valve Movement Valve Adaptatio failed reserved reserved reserved
too slow (E2) (E1)
7.3.4 CURRENT TEMPERATURE SETPOINT
Any value written to Thermostat / Occupied / Unoccupied Heating Setpoint attribute (0x0012 or 0x0014) will auto-
matically be copied to the Current Temperature Set point attribute (0x4003) to allow operating the TRV without the
need to be aware of the customer specific attributes.
7.4 ATTRIBUTE REPORTING
Pre-Configured
Reporting Interval
Device Type
Cluster
Attribute
Attribute ID
TRV
Report on change
Thermostat
Errors
0x4002
TRV
TRV
Report on change
Report on change
Thermostat
Thermostat
Current Temperature
Set point
0x4003
0x4008
Host Flags
– 16 –
| General | Details |
|---|---|
| Name | eurotronic Comet Zigbee Energy Saving Radiator Thermostat Instruction Manual |
| Make | EUROTRONIC |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.47 MB |

EUROTRONIC Sparmatic COMET Programmable Energy-Saving Radiator Thermostat User Manual

EUROTRONIC Programmable Energy-Saving Radiator Thermostat User Manual

EUROTRONIC SPIRIT ZigBee Energy Saving Thermostat User Guide

EUROTRONIC COMET Programmable Energy Saving Radiator Thermostat User Manual

EUROTRONIC Spirit ZigBee Energy Saving Radiator Thermostat User Guide