Home > ESi Controls > ESi Controls ESRTERFW Wireless Digital Room Thermostat Installation Guide
ESi Controls ESRTERFW Wireless Digital Room Thermostat Installation Guide
Thank you for choosing ESi Controls
All our products are tested in the UK so we are confident this product
will reach you in perfect condition and give you many years of
service. However, for additional peace of mind, we recommend you
your extended 3-year warranty within 30 days of purchase. Products
registered after 30 days of purchase will qualify for 1 year warranty.
Installation Safety Instructions
The unit must be installed by a suitably qualified person in
accordance with the latest IEE Wiring Regulations. Isolate mains
supply before commencing installation. Please read all instructions
before proceeding. Ensure that the fixed wiring connections to the
mains supply is via a fuse rated at not more than 6 amps and class
‘A’ switch having a contact separation of a minimum of 3mm in all
poles. The recommended cable sizes are 1.0mm sqr or 1.5mm sqr.
No earth connection is required as the product is double insulated
but ensure continuity of earth throughout the system.
2
Contents
Installation Safety Instructions.…..…….…………………….…...…….2
Technical Data.…………………………………………………………...4
Maintenance.……………………….………………...…………………..4
Safety Notice……………………………………….……………………..5
Installing the Room Thermostat…………………………………………5
Installing the RF Receiver…………………..…………………………...6
RF Pairing (Commissioning/Configuring…….…………………………6
Wiring…………………………………………………………..………….7
DIP Switch Settings………………………………………………………7
RF Receiver Buttons……………………………………………………..7
3
Technical Data
Wireless Digital Room Thermostat with TPI
Fixing
Easy Fit Back Plate
Electronic Thermistor
2 x AA Batteries
Sensing Element
Power Supply
Switch Action
3(1)A 230VAC
Temperature Setting Range 5°C to 30°C
Current Rating
Terminal Differential
Switch Type
Maximum 3(1) Amp
0.6°C at 4°/hour
SPDT
Dimensions
L: 85mm x H:85mm x D: 35mm
EN60730-1, EN60730-2.7,
EMC Directive 2004/108/EC,
LVD Directive 2006/95/EC
Complies with
RF Receiver
Fixing
Easy Fit Back Plate
Power Supply Voltage
Power Consumption
Contact Type
230VAC, 50Hz
6W
6 (2)A, 230VAC SPDT (Volt Free
Changeover Contacts)
Thermoplastic, flame retardant
IP30
L: 135mm x W: 90mm x D: 33mm
EN60730-1, EN60730-2.7,
EMC Directive 2004/108/EC,
LVD Directive 2006/95/EC
Plastic
Protection Rating
Dimensions
Complies With
Maintenance
Always isolate the mains supply before commencing any work,
servicing or maintenance on the system. And please read all the
instructions before proceeding. Arrange for an annual maintenance
and inspection schedule to be carried out by a competent person on
every part of the heating and hot water system.
4
| General | Details |
|---|---|
| Name | ESi Controls ESRTERFW Wireless Digital Room Thermostat Installation Guide |
| Make | ESi Controls |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.17 MB |