ECO500 Frost protection thermostat  
Installation and Operating Instructions  
ECO500 is an electronic thermostat for frost protection of drain pipes.  
1. Safety Instructions  
Electrically skilled person  
The installation must only be done by an electrician with the appropriate qualifications.  
Follow the instructions in this manual, and make sure that the installation complies with national  
safety regulations, installation methods and restrictions.  
The information provided in this manual in no way exempts the installer or user from responsibil-  
ity to follow all applicable safety regulations.  
Keep this manual for future installation and service.  
WARNING  
Danger of electric shock! Risk of fire!  
Disconnect the power supply before carrying out any installation or maintenance work on this  
thermostat and associated components.  
Do not switch on the power supply before the installation work is completed.  
Improper installation can cause personal injury and property damage.  
Do not operate a defect thermostat.  
2. Installation Instructions  
Install the thermostat in accordance with figures 1 and 2.  
Attach the sensor outside the pipe on the opposite side of the heating cable, and in such a manner that  
it measures the coldest spot of the pipe.  
A residual circuit breaker must be used in accordance with the local installation regulations.  
3. User Instructions  
Set the temperature by turning the adjustment wheel, figure 1.  
Switch off the power before you remove the thermostat cover!  
4. Warranty  
The warranty period for Ensto ECO thermostats is 2 years from the date of purchase but no longer than  
3 years from the date of manufacture. Warranty conditions, see www.ensto.com/building-systems  
5. Disposal  
Do not dispose of electrical and electronic devices including their accessories with the household  
waste.  
The product’s cardboard packing is suitable for recycling.  
When a heating system is at the end of the life cycle the cables, conduits and electronic components must  
be disposed of properly according to local recycling guidelines.  
6. Technical Data  
Rated voltage  
230V/50Hz, -15%/+10%  
Adjustment range  
Load (max)  
+2 ... +35 ºC  
3600W, 16A cosφ = 1 / 2A cosφ = 0,4  
Nominal current  
Sensor  
16A  
NTC / cable 4m, extendable, max 50m (2 x 1,5 mm2)  
Sensor resistance values  
Ambient temperature (ta)  
Ingress protection  
Table on page 2 (sensor is not connected)  
-30 … +30 ºC  
IP55  
RAK59 / 2023-03-15  
5 / 16  
GeneralDetails
NameENSTO ECO500 Frost Protection Thermostat Instruction Manual
MakeENSTO
LanguageEnglish
FiletypePDF (Download)
File size0.96 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
ENSTO ECO10BTW-J Floor Heating Thermostat Instruction Manual
ENSTO ECO10BTW-J Floor Heating Thermostat Instruction Manual
ENSTO ECO16BTD Floor Heating Thermostat User Guide
ENSTO ECO16BTD Floor Heating Thermostat User Guide
ENSTO ECO16BT-J Floor Heating Thermostat User Guide
ENSTO ECO16BT-J Floor Heating Thermostat User Guide
ENSTO ECO16BT-E Floor Heating Thermostat User Guide
ENSTO ECO16BT-E Floor Heating Thermostat User Guide
ENSTO ECO10BTW-J Heat Control Thermostat Instruction Manual
ENSTO ECO10BTW-J Heat Control Thermostat Instruction Manual
Ensto ECO16BT-IN-WW Floor Heating Thermostat User Guide
Ensto ECO16BT-IN-WW Floor Heating Thermostat User Guide
ENSTO ECO16TOUCH Combination Thermostat Instruction Manual
ENSTO ECO16TOUCH Combination Thermostat Instruction Manual
ENSTO ECO16BTD Combination Thermostat Instruction Manual
ENSTO ECO16BTD Combination Thermostat Instruction Manual
ENSTO ECO16BT-EX Floor Heating Thermostat User Guide
ENSTO ECO16BT-EX Floor Heating Thermostat User Guide

ENSTO ECO500 Frost Protection Thermostat Instruction Manual