Home > EBECO > Ebeco EB-Therm 55 Thermostat User Manual

Ebeco EB-Therm 55 Thermostat User Manual

Troubleshooting  
Important The underfloor heating  
system is an electrical power installa-  
tion and any faults must therefore be  
remedied by a qualified electrician.  
Fault indication  
If the floor/room sensor is damaged or  
interrupted, the thermostat will cut out  
and the lamp start to flash alternatingly  
green and red.  
If the floor sensor should become  
faulty, it can be replaced provided it  
is installed in a spiral hose laid in the  
floor as instructed. The room sensor  
cannot be replaced. The thermostat  
must be replaced if there is a fault with  
the room sensor.  
Test values for floor sensor  
The following values apply when the  
floor sensor’s measurements are  
checked.  
Temperature Resistance  
10 oC  
15 oC  
20 oC  
25 oC  
30 oC  
18,0 kΩ  
14,7 kΩ  
12,1 kΩ  
10,0 kΩ  
8,3 kΩ  
28  