Dettson R02P034 Communicating Thermostat Instruction Manual

- Unit Info  
Code Parameter  
Indications  
Comments  
Model Number XXXX-XXXXXXXXXXXXXXX Unit model number  
Serial Number XXXXXXXXXXXXXXXXXXX Unit serial number  
Software Vers XXXXXX  
- Setup  
Code Parameter  
Heat Rise Adjust 55F, 65F  
Min Heat Adj % -15, -7, 0, 7, 15 Airflow adjustments at 40% firing rate  
Max Heat Adj % -15, -7, 0, 7, 15 Airflow adjustments at 100% firing rate  
Control software version  
Indications  
Comments  
Adjust heat temperature rise  
Fixed Fire Rate  
Reset All Dflts  
Off - 100% Heat at fixed rate  
0 (no) , 1 (yes) Reset furnace settings to factory defaults  
Supreme Electric Furnace User Menus  
- Status  
Code Parameter Indications Comments  
CFM  
CMD  
Version  
XXXX CFM Current airflow  
XXX %  
X_X_X  
% of active electric elements  
Firmware version  
- Fan  
Code Parameter  
Cont Fan Ratio 0-100, FC*  
Indications Comments  
% CFM when fan on  
Rise  
20-80, FC*  
Temperature rise (°F)  
- Autobackup  
Code Parameter  
Enabled  
Indications  
0 (no) , 1 (yes) If autobackup is enabled  
Normal, Fusion Autobackup mode  
Comments  
Mode  
Wait Time  
0-120, FC*  
Wait time before autobackup (min)  
Update Delay 0-30, FC*  
Set PT Offset 0.0-3.5, FC*  
Lockout temp -20-20, FC*  
Time before updating autobackup command (sec)  
Minimum offset with setpoint for autobackup (°F)  
Furnace lockout temprature (°C)  
Rise  
20-80, FC*  
Temperature rise (°F) for autobackup  
- System  
Code Parameter  
Indications  
005-120, FC*  
AC/HP OFF Delay 005-240, FC*  
Comments  
AC/HP ON Delay  
Fan delay after AC/HP start (sec.)  
Fan delay after AC/HP stop (sec.)  
% of max. power of the furnace  
Ratio Max Pwr  
Dual Heat  
20-100, FC*  
NOR, HP, DOUB Dual heat option  
- Reset  
Code Parameter  
Indications Comments  
Factory Values 0 (no) , 1 (yes) Reset furnace settings to factory defaults  
* FC values will be shown if a more precise value has been configured at the furnace control (refer  
to the Supreme furnace manual).  
12  
GeneralDetails
NameDettson R02P034 Communicating Thermostat Instruction Manual
MakeDettson
LanguageEnglish
FiletypePDF (Download)
File size0.28 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Dettson 2-Stage WiFi Thermostat R02P033 Owner’s Manual
Dettson 2-Stage WiFi Thermostat R02P033 Owner’s Manual

Dettson R02P034 Communicating Thermostat Instruction Manual