Dettson R02P034 Communicating Thermostat Instruction Manual
3 Thermostat Settings
Press
Use
to access the settings menu.
and to change the parameter value.
Use
Use
to move to next parameter and
to move to the previous parameter.
to exit to the main display.
Item Description
Range
Defualt
0°C / 0°F
10°C / 50°F
30°C / 86°F
30%
Note
P1
P2
P3
Temperature adjustment
Min. set point
Max. set point
-6 to 6°C / -12 to 12°F
5 to 35°C / 41 to 95°F
5 to 35°C / 41 to 95°F
30 to 70%
Cooling
Heating
P22 Continuous fan ratio
P30 Beeper
0: Disabled
1: Enabled
Read-only
0: Do not reset
1: Reset
0 / 1
0 - 999 hours
0 / 1
1
-
P40 Air filter counter
P41 Air filter counter reset
0
0
P42 Air filter alarm delay
P49 Heat/cool switchover
0 - 999 hours
0 to 10°C / 0 to 20°F
0: Disabled
2.0°C / 4.0°F Auto mode only
0: Disabled
1: Enabled
100 Dimming
0 / 1
1
102 Dimming brightness
105 Brightness
0 to 90%
50 to 100%
10%
100%
0: Disabled
1: 1 day
107 Schedule program
0 - 4
0
2: 5+2 days
3: 5+1+1 days
4: 7 days
0: 2 periods
1: 4 periods
0: 12h
108 Day periods
0 / 1
0 / 1
1
0
109 Clock format
1: 24h
122 Cool modulation speed
123 Heat modulation speed
124 Balance point
0 - 100 sec.
0 - 100 sec.
-30 to 15°C / -22 to 59°F -20°C / -4°F
3 sec.
3 sec.
125 Aux. heat temp. diff.
Humidity or outdoor
temp. display
-1 to -4°C / -1 to -7°F
-1.5°C / -2°F
0: Disabled
1: Enabled
187
0 / 1
1
0: Humidity
1: Outdoor temperature
191 Display selection (187)
0 / 1
0
194 Humidity deadband
195 Humidity adjustment
197 Humidity set point
2 to 20%
-9 to 9%
20 to 100%
5%
0%
45%
0: °F
1: °C
199 Temperature unit
0 / 1
0 / 1
1
0
0: Do not reset
1: Reset
200 Factory reset
9