Menu CF06 Activation/Deactivation of the anti-seizing function
Anti-seize can be used outside heating periods to regularly start up the circulator during off periods (5 minutes/
week).
Anti-seize off
Default seting: Anti-seize disabled
Anti-seize on
Menu CF08 Control time base
The control quality depends on parameters like the building’s insulation, the number of radiators or the flooring
type.
The “Tips” column in the following table will help you select the seting that is appropriate for your installation.
Default seting: 15 minutes.
Choice of
control type
Generator
Transmiter type
Tips
type
Increase the time base to extend generator
run times and thus reduce the frequency of
start up.
Boiler/Heat pump
15 minutes (2)
Heater
(1)
Increase the time base to extend generator
run times and thus reduce the frequency of
start up.
Radiator
Underfloor heating
Boiler/Heat pump
30 minutes (2)
(1)
Boiler/Heat pump
45 minutes (2)
Underfloor heating
(1)
Reduce the time base if you notice big
differences in temperature.
60 minutes (2)
Underfloor heating
Heat pump (1)
Only recommended if the PID control isn't
Radiator
Underfloor heating
satisfactory.
Recommended hysteresis value: between 0.4
and 1
Heat pump (1)
On-Off (3)
Oven range
Hysteresis value: follow the value
heating
recommended by the range's manufacturer
(1) The control is fited with anti-short cycle protection to suppress start or stop requests when they are too short. The anti-short cycle
duration is 10% of the time base selected (e.g.: if the time base is set to 30 minutes, the anti-short cycle will be 3 minutes, i.e. the
thermostat will not accept any start or stop requests that are under 3 minutes).
(2) PID control time base:
(3) On-off control: not compatible with the RF6420 and RF6450 receivers.
Menu 2-11 Hysteresis seting if 2-08 = tor)
Default seting: 0.4°C.
Example:
Adjusts from 0.2°C to 2°C,
Setpoint 20°C. Hysteresis 0.4°C.
in increments of 0.1°C.
Heating request if T° measured <19.8°C.
Heating shuts down if T° measured> 20.2°C.
Exiting the Configuration Menu
Press mode for 5 seconds.
5
| General | Details |
|---|---|
| Name | DELTA DORE Tybox 2300 Wireless Thermostat User Guide |
| Make | DELTA DORE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 9.23 MB |

DELTA DORE TYBOX 1127 Programmable Thermostat User Guide

DELTA DORE TYBOX 1117 Programmable Thermostat User Guide

DELTA DORE Tybox 5701FP Pilot Wire Thermostat User Guide

DELTA DORE Tywell 2050 Thermostat D’Ambiance Radio Installation Guide